TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Battery report threshold | When battery level exceeds threshold, the unit need to report to hub. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 1 | 20 | No | No | No |
Value |
Description |
||||
1 | Battery report threshold % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | Humidity Upper | Humidity Upper Watermark value | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Humidity Upper Watermark value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | Humidity Lower | Humidity Lower Watermark value | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Humidity Lower Watermark value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | Temperature unit | Switch the unit of Temperature report | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Celsius | ||||
1 | Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | Group 2 Funtion | Association Group 2 Setting | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 6 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Send Basic SET 0xFF when Magnet is away,and send Basic SET 0x00 when Magnet is near | ||||
2 | Send Basic SET 0x00 when Magnet is away,and send Basic SET 0xFF when Magnet is near. | ||||
3 | Only send Basic SET 0xFF when Magnet is away. | ||||
4 | Only send Basic SET 0x00 when Magnet is near. | ||||
5 | Only send Basic SET 0x00 when Magnet is away. | ||||
6 | Only send Basic SET 0xFF when Magnet is near | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Low battery alarm report threshold | Setting the threshold for low battery alarm report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 5 | 20 | No | No | No |
Value |
Description |
||||
5 | Low battery alarm report threshold % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | state of the door sensor | Parameter defines state of the sensor when the magnet closes the reed | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | door/window closed when magnet closes the reed | ||||
1 | door/window opened when magnet closes the reed | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 2 | Door close send command time | Delay in seconds when door closed | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3600 | No | No | No |
Value |
Description |
||||
0 | Door close send command time | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 2 | Door open send command time | Delay in seconds when door opened | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3600 | No | No | No |
Value |
Description |
||||
0 | Door open send command time | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Temperature report threshold | Minimum Temperature change to report | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 1 | 9 | No | No | No |
Value |
Description |
||||
1 | Temperature report threshold | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Humidity report threshold | Minimum humidity change to report | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 5 | 20 | No | No | No |
Value |
Description |
||||
5 | Humidity report threshold | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Temperature Upper | Temperature Upper Watermark value | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 50 | No | No | No |
Value |
Description |
||||
0 | Temperature Upper Watermark value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Temperature Lower | Temperature Lower Watermark value | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 50 | No | No | No |
Value |
Description |
||||
0 | Temperature Lower Watermark value | ||||