TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Door/Window Temperature & Humidity Sensor (MSE30Z)

Z-Wave Certification Number: ZC12-21070245


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Battery report threshold When battery level exceeds threshold, the unit need to report to hub.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 1 20 No No No

Value

 

Description

1   Battery report threshold %

Parameter Number

Parameter Size

Parameter Name

Description

10 1 Humidity Upper Humidity Upper Watermark value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 100 No No No

Value

 

Description

0   Humidity Upper Watermark value

Parameter Number

Parameter Size

Parameter Name

Description

11 1 Humidity Lower Humidity Lower Watermark value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 100 No No No

Value

 

Description

0   Humidity Lower Watermark value

Parameter Number

Parameter Size

Parameter Name

Description

12 1 Temperature unit Switch the unit of Temperature report

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Value

 

Description

0   Celsius
1   Fahrenheit

Parameter Number

Parameter Size

Parameter Name

Description

13 1 Group 2 Funtion Association Group 2 Setting

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 6 No No No

Value

 

Description

0   Disable
1   Send Basic SET 0xFF when Magnet is away,and send Basic SET 0x00 when Magnet is near
2   Send Basic SET 0x00 when Magnet is away,and send Basic SET 0xFF when Magnet is near.
3   Only send Basic SET 0xFF when Magnet is away.
4   Only send Basic SET 0x00 when Magnet is near.
5   Only send Basic SET 0x00 when Magnet is away.
6   Only send Basic SET 0xFF when Magnet is near

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Low battery alarm report threshold Setting the threshold for low battery alarm report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 5 20 No No No

Value

 

Description

5   Low battery alarm report threshold %

Parameter Number

Parameter Size

Parameter Name

Description

3 1 state of the door sensor Parameter defines state of the sensor when the magnet closes the reed

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   door/window closed when magnet closes the reed
1   door/window opened when magnet closes the reed

Parameter Number

Parameter Size

Parameter Name

Description

4 2 Door close send command time Delay in seconds when door closed

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3600 No No No

Value

 

Description

0   Door close send command time

Parameter Number

Parameter Size

Parameter Name

Description

5 2 Door open send command time Delay in seconds when door opened

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3600 No No No

Value

 

Description

0   Door open send command time

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Temperature report threshold Minimum Temperature change to report

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 1 9 No No No

Value

 

Description

1   Temperature report threshold

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Humidity report threshold Minimum humidity change to report

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 5 20 No No No

Value

 

Description

5   Humidity report threshold

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Temperature Upper Temperature Upper Watermark value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 50 No No No

Value

 

Description

0   Temperature Upper Watermark value

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Temperature Lower Temperature Lower Watermark value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 50 No No No