Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
151 | 2 | Threshold of power report | 0 to 200 (Default) |
Available values: 0 - 200 (0 - 200W) | |
0 | 0 - The function is disabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
152 | 1 | Percentage threshold for power reporting | 0 | The function is disabled. | |
0 to 100 (Default) |
Available values: 0 - 100 (0 - 100%) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
171 | 4 | Frequency of power reports | 0 | The function is disabled. | |
3600 to 2678400 (Default) |
Available values: 3600- 2678400 (3600 - 2678400s) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
172 | 4 | Frequency of energy reports | 0 | The function is disabled. | |
3600 to 2678400 (Default) |
Available values: 3600- 2678400 (3600 - 2678400s) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
173 | 4 | Frequency of voltage reports | 0 (Default) |
The function is disabled. | |
3600 to 2678400 | Available values: 3600- 2678400 (3600 - 2678400s) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
174 | 4 | Frequency of electric current reports | 0 (Default) |
The function is disabled. | |
3600 to 2678400 | Available values: 3600- 2678400 (3600 - 2678400s) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Overload protection | 0 | The function is disabled | |
1 (Default) |
The function is enabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Device state after power on | 0 (Default) |
The Smart Plug will remain in the same state as it was before the power off. | |
1 | The smart plug is turned on by default. | ||||
2 | The smart plug is turned off by default. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | Send reports when load status changes | 0 | The function is disabled. | |
1 (Default) |
Send Basic report. | ||||
2 | Send Basic report only when Load condition is not changed by Z-WAVE Command. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
254 | 1 | Enable/Disable the configuration command | 0 (Default) |
Enable | |
1 | Disable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | The state of indicator light | 0 (Default) |
The indicator light remains the same as the load on/off status. When the load is on, the light is on. When the load is off, the light is off. | |
1 | Within 5 seconds after the operation load, the indicator light is consistent with the load on/off status, and then the indicator turns off. | ||||