Z-Wave Products

There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: In Wall Dual relay switch module (PAN30-JP)

Z-Wave Certification Number: ZC12-21070244


Parameter Number

Parameter Size

Parameter Name

Description

1 2 Watt Meter Report Period If the setting is configured for 1hour (set value =720), the PAN30 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). If the setting value is 0, the auto report function of meter Watt will be disabled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

720 0 32767 No No No

Value

 

Description

0   The auto report function of meter Watt will be disabled.
1   720*5s=3600s= 1 hour

Parameter Number

Parameter Size

Parameter Name

Description

2 2 KWH Meter Report Period If the setting is configured for 1hour (set value =6), the PAN30 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). If the setting value is 0, the auto report function of meter KWh will be disabled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

6 0 32767 No No No

Value

 

Description

0   The auto report function of meter KWh will be disabled.
1   6*10min= 1 hour

Parameter Number

Parameter Size

Parameter Name

Description

3 2 Threshold of current for Load Caution This is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of Relay1 or Relay2 over this value, PAN30 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

750 10 750 No No No

Value

 

Description

10   750*0.01A = 7.5A

Parameter Number

Parameter Size

Parameter Name

Description

4 2 Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN30 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10000 1 10000 No No No

Value

 

Description

1   1KWh ~ 10000KWh

Parameter Number

Parameter Size

Parameter Name

Description

5 1 External switch mode Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 3 No No No

Bit (Value)

 

Description

1 (2)   Edge mode
2 (4)   Pulse mode
3 (8)   Edge-Toggle mode

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Restore switch state mode Whenever the AC power return from lost, PAN30 will restore the switch state which could be SWITCH OFF、LAST SWITCH STATE、SWITCH ON. The default setting is LAST SWITCH STATE.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Bit (Value)

 

Description

0 (1)   Switch off
1 (2)   Last switch state
2 (4)   Switch on

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Watt differential report mode It will trigger a Watt report when the variation of watt value is over the preset percentage.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 4 No No No

Bit (Value)

 

Description

0 (1)   The function of Watt differential report will be disabled.
1 (2)   5%
2 (4)   10%
3 (8)   15%
4 (16)   20%