TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Switch set | To select connected switch function. Setting value: 0: Only S1 is effective 1: Both S1 and S2 are effective. 2: S1 dimmer up S2 dimmer down | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 0 | 0: Only S1 is e ective | |||
1 | 1 | 1: Both S1 and S2 are e ective. | |||
2 | 2 | 2: S1 dimmer up S2 dimmer down | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Power-on recovery status set | To set dimmer level when AC power on. Setting value: 0: OFF-0% 1: ON-last level 2: ON-100% | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 0 | 0: OFF-0% | |||
1 | 1 | 1: ON-last level | |||
2 | 2 | 2: ON-100% | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | RF report set | To set if device send Multilevel Switch report to gateway when dimming finished. Setting value: 1: report ON 0: report OFF | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
From |
To |
Description |
|||
0 | 0 | 0: report OFF | |||
1 | 1 | 1: report ON | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Maximum level | To set dimming level maximum value. Dimming level will not over the setting value. Setting value: Cannot be lower than the Minimum level | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
99 | 1 | 99 | No | No | No |
From |
To |
Description |
|||
1 | 99 | 1~99 : 1% ~ 99% | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Minimum level | To set dimming level minimum value. Dimming level will directly go to 0% when dimming value is lower than the setting value. Setting value: Cannot be higher than the Maximum level | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 98 | No | No | No |
From |
To |
Description |
|||
0 | 98 | 0~98 : 0% ~ 98% | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Basic duration set | Unit: second To set dimming finished duration time when physical switch used. Ex: When setting is 2, it will take 2 seconds from switch on action to dimming finished. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 127 | No | No | No |
From |
To |
Description |
|||
0 | 127 | Unit: second ,0 ~127second | |||