There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Auto Report Tick Interval | The interval time for auto report each tick. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
30 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | The interval time for auto report each tick. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Sound Duration | Play sound duration, 1 tick is 30 seconds. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
6 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Play sound duration, 1 tick is 30 seconds. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Customer Function | Customer function switch, using bit control. Bit0: Disable Trigger Alarm. 0:Enable , 1:Disable. Bit1: Disable Sound. Only using optical alarm. 0:Enable , 1:Disable. Bit2: Temperature Unit. 0:Fahrenheit , 1:Celsius. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Auto Report Temperature Time | The interval time for auto report the temperature. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
12 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | The interval time for auto report the temperature. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Temperature Differential Report | The temperature differential to report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | The temperature differential to report. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Auto Report Battery Time | The interval time for auto report the battery level. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
12 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | The interval time for auto report the battery level. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Play Sound Control | Control play sound's level and which sound. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
67 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Control play sound's level and which sound. | ||||