There are over 4252 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
110 | 1 | Single Tap behavior | Select behavior when single tap. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | Last brightness level | ||||
1 | Custom value from Param 133 | ||||
2 | Max brightness from Param 132 | ||||
3 | Full brightness at 100% | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
111 | 1 | Double Tap behavior | Select behavior when double tap. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | Full brightness at 99 | ||||
1 | Custom value from Param 133 | ||||
2 | Max brightness from Param 132 | ||||
3 | Disable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
119 | 1 | External Switch Scene | Enable or disable the scene function of external(3-way) switch. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
120 | 1 | External Switch Type | Select the external(3- way) switch's type. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | toggle on or off only | ||||
1 | toggle switch/1x to toggle /2x use Param 132 or 133 /3x toggle dimmer loop ramp -> toggle once more to stop dim | ||||
2 | momentary switch / 1x to toggle / 2x user Param 132 or 133/ Press and hold to dim up and down | ||||
3 | momentary switch / 1x quick toggle / 2x user Param 132 or 133 / Press and hold to dim up and down (but after a double click to full brightness, then press and hold will always go down instead of increasing) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
121 | 1 | Output Control | Enable or disable output. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 0 | 3 | No | No | No |
Value |
Description |
||||
1 | enable local control | ||||
2 | enable central scene | ||||
3 | enable local and central scene | ||||
0 | Disable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
122 | 1 | Button Function | Select the paddle button functions. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | up/ON, down/OFF | ||||
1 | down/ON, up/OFF | ||||
2 | toggle (up or down are the same) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
123 | 1 | Report Behavior | Select behavior for report and indicator when output is disable. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | report on/off status and change LED indicator when parameter 121 is set to 0 or 2 | ||||
1 | Don't report on/off status is pressed and parameter 121 is set to 0 or 2 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
125 | 1 | Ramp Rate for Tap and Hub control | Setting ramp rate when tap to on off or controlled by HUB. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 99 | No | No | No |
Value |
Description |
||||
0 | instant | ||||
1 | Ramp Rate 1-99s | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
126 | 1 | Ramp Rate for press and hold | Setting ramp rate when press and hold the paddle. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
4 | 1 | 99 | No | No | No |
Value |
Description |
||||
1 | Ramp Rate 1-99s | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
131 | 1 | Minimum most dim setting | Setting the minimum value of dimmer. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 99 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Minimum value is 1-99 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
132 | 1 | Maximum most dim setting | Setting the maximum value of dimmer. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
100 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Minimum value is 1-100 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
133 | 1 | Custom brightness | Setting user custom brightness. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 99 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | custom brightness level is 1-99 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
20 | 1 | Power Restore | Status after power failure. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | return to OFF | ||||
1 | return to ON | ||||
2 | return to last known state when repowered | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
40 | 4 | Auto Turn Off Timer | Timer that auto turn off once turned on. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | auto turn off after 1-65535s once turned on. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
41 | 4 | Auto Turn On Timer | Timer that auto turn on once turned off. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | auto turn on after 1-65535s once turned off. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
80 | 1 | Instant Status Report | The command for status report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Nothing | ||||
1 | Basic Report | ||||
2 | Binary Switch Report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
82 | 1 | Association Control Settings | Setting command for association group. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 2 | No | No | No |
Value |
Description |
||||
1 | Basic Set | ||||
2 | Binary Switch Set | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
83 | 1 | Led Indicator Settings | Select the indicator function for output. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Momentary blink | ||||
2 | LED follows status of output | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
84 | 1 | Led Indicator Color For Output | Select the indicator color for output. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
9 | 0 | 9 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Red | ||||
2 | Blue | ||||
3 | Green | ||||
4 | Pink | ||||
5 | Cyan | ||||
6 | Puple | ||||
7 | Orange | ||||
8 | Yellow | ||||
9 | White | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
85 | 1 | Led Indicator Color For Scene | Select the indicator color for scene. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 9 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Red | ||||
2 | Blue | ||||
3 | Green | ||||
4 | Pink | ||||
5 | Cyan | ||||
6 | Purple | ||||
7 | Orange | ||||
8 | Yellow | ||||
9 | White | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
86 | 1 | Led Brightness | Setting the brightness of indicator. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | 1%-100% level | ||||