Z-Wave Products

There are over 4408 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: illumino Wall Switch (ZWA038-A)

Z-Wave Certification Number: ZC12-21080286


Parameter Number

Parameter Size

Parameter Name

Description

119 1 External Switch Scene Enable or disable the scene function of external(3-way) switch.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Value

 

Description

0   Disable
1   Enable

Parameter Number

Parameter Size

Parameter Name

Description

120 1 External Switch Type Select the external(3-way) switch's type.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   toggle on or off only
1   NO momentary switch
2   NC momentary switch

Parameter Number

Parameter Size

Parameter Name

Description

121 1 Output Control Enable or disable output.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 0 3 No No No

Value

 

Description

0   Disable
1   enable local control
2   enable central scene
3   enable local and central scene

Parameter Number

Parameter Size

Parameter Name

Description

122 1 Button Function Select the paddle button functions.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   up/ON, down/OFF
1   down/ON, up/OFF
2   toggle (up or down are the same)

Parameter Number

Parameter Size

Parameter Name

Description

123 1 Report Behavior Select behavior for report and indicator when output is disable.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   0- report on/off status and change LED indicator when parameter 121 is set to 0 or 2
1   1- Don't report on/off status is pressed and parameter 121 is set to 0 or 2

Parameter Number

Parameter Size

Parameter Name

Description

20 1 Power Restore Status after power failure.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Value

 

Description

0   return to OFF
1   return to ON
2   returns to last known state when repowered

Parameter Number

Parameter Size

Parameter Name

Description

40 4 Auto Turn Off Timer Timer that auto turn off once turned on.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   Disable
1   Auto turn off after 1s once turned on 65535 - Auto turn off after 65535s once turned on

Parameter Number

Parameter Size

Parameter Name

Description

41 4 Auto Turn On Timer Timer that auto turn on once turned off.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   Disable
1   auto turn on after 1-65535s once turned off.

Parameter Number

Parameter Size

Parameter Name

Description

80 1 Instant Status Report The command for status report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Value

 

Description

0   Nothing
1   Basic Report
2   Binary Switch Report

Parameter Number

Parameter Size

Parameter Name

Description

82 1 Association Control Settings Setting command for association group.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 2 No No No

Value

 

Description

1   Basic Set
2   Binary Switch Set

Parameter Number

Parameter Size

Parameter Name

Description

83 1 Led Indicator Settings Select the indicator function for output.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Value

 

Description

0   Disable
1   Momentary blink
2   LED follows status of output

Parameter Number

Parameter Size

Parameter Name

Description

84 1 Led Indicator Color For Output Select the indicator color for output.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

9 0 9 No No No

Value

 

Description

0   Disable
1   Red
2   Blue
3   Green
4   Pink
5   Cyan
6   Puple
7   Orange
8   Yellow
9   White

Parameter Number

Parameter Size

Parameter Name

Description

85 1 Led Indicator Color For Scene Select the indicator color for scene.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 9 No No No

Value

 

Description

0   Disable
1   Red
2   Blue
3   Green
4   Pink
5   Cyan
6   Purple
7   Orange
8   Yellow
9   White

Parameter Number

Parameter Size

Parameter Name

Description

86 1 Led Brightness Setting the brightness of indicator.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

60 0 100 No No No

Value

 

Description

0   Disable
1   1%-100% level