There are over 4408 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
119 | 1 | External Switch Scene | Enable or disable the scene function of external(3-way) switch. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
120 | 1 | External Switch Type | Select the external(3-way) switch's type. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | toggle on or off only | ||||
1 | NO momentary switch | ||||
2 | NC momentary switch | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
121 | 1 | Output Control | Enable or disable output. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | enable local control | ||||
2 | enable central scene | ||||
3 | enable local and central scene | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
122 | 1 | Button Function | Select the paddle button functions. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | up/ON, down/OFF | ||||
1 | down/ON, up/OFF | ||||
2 | toggle (up or down are the same) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
123 | 1 | Report Behavior | Select behavior for report and indicator when output is disable. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | 0- report on/off status and change LED indicator when parameter 121 is set to 0 or 2 | ||||
1 | 1- Don't report on/off status is pressed and parameter 121 is set to 0 or 2 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
20 | 1 | Power Restore | Status after power failure. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | return to OFF | ||||
1 | return to ON | ||||
2 | returns to last known state when repowered | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
40 | 4 | Auto Turn Off Timer | Timer that auto turn off once turned on. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Auto turn off after 1s once turned on 65535 - Auto turn off after 65535s once turned on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
41 | 4 | Auto Turn On Timer | Timer that auto turn on once turned off. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | auto turn on after 1-65535s once turned off. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
80 | 1 | Instant Status Report | The command for status report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Nothing | ||||
1 | Basic Report | ||||
2 | Binary Switch Report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
82 | 1 | Association Control Settings | Setting command for association group. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 2 | No | No | No |
Value |
Description |
||||
1 | Basic Set | ||||
2 | Binary Switch Set | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
83 | 1 | Led Indicator Settings | Select the indicator function for output. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Momentary blink | ||||
2 | LED follows status of output | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
84 | 1 | Led Indicator Color For Output | Select the indicator color for output. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
9 | 0 | 9 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Red | ||||
2 | Blue | ||||
3 | Green | ||||
4 | Pink | ||||
5 | Cyan | ||||
6 | Puple | ||||
7 | Orange | ||||
8 | Yellow | ||||
9 | White | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
85 | 1 | Led Indicator Color For Scene | Select the indicator color for scene. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 9 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | Red | ||||
2 | Blue | ||||
3 | Green | ||||
4 | Pink | ||||
5 | Cyan | ||||
6 | Purple | ||||
7 | Orange | ||||
8 | Yellow | ||||
9 | White | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
86 | 1 | Led Brightness | Setting the brightness of indicator. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | 1%-100% level | ||||