There are over 4408 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 2 | Watt Meter Report Period | If the setting is configured for 1hour (set value =720), the PAN34 will report its instant power consumption every 1 hour to the node of Group 1. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Default value is 1 hour. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
720 | 0 | 32767 | No | No | No |
Value |
Description |
||||
0 | Disable auto Report | ||||
1 | 5s~45 hour | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | External switch mode | It is used to define the external button mode. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 1 | 2 | No | No | No |
Bit (Value) |
Description |
||||
1 (2) | One Push button | ||||
2 (4) | Two Push button | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 2 | Total moving time of curtain | This is a way for setting the total moving time of curtain manually. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 6000 | No | No | No |
Value |
Description |
||||
0 | The time depends on Moving Range Calibration | ||||
1 | 0.1s~600s | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Watt threshold | The threshold is for PAN34 judging if the motor is running or not. The default value is 1 watt. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 5 | No | No | No |
Value |
Description |
||||
1 | The threshold is a judgment for motor running or not | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Watt differential | Whenever the watt value varies over 5%, PAN34 will send the meter report to group 1 nodes. The default value is 1 (5%). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | It will not report Watt when change over 5% | ||||
1 (2) | It will report watt value when the di erential is over 5% | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 2 | Timer offset for motor start running | This parameter is an offset to count for starting time of the motor. It will improve the inaccurate when moving to the middle position. The default value is 50. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
50 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | 0s ~ 2.55s, 50 = 0.5s | ||||