Z-Wave Products

There are over 4408 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: In Wall Roller shutter Controller (PAN34-IN)

Z-Wave Certification Number: ZC12-21080281


Parameter Number

Parameter Size

Parameter Name

Description

1 2 Watt Meter Report Period If the setting is configured for 1hour (set value =720), the PAN34 will report its instant power consumption every 1 hour to the node of Group 1. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Default value is 1 hour.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

720 0 32767 No No No

Value

 

Description

0   Disable auto Report
1   5s~45 hour

Parameter Number

Parameter Size

Parameter Name

Description

2 1 External switch mode It is used to define the external button mode.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 1 2 No No No

Bit (Value)

 

Description

1 (2)   One Push button
2 (4)   Two Push button

Parameter Number

Parameter Size

Parameter Name

Description

3 2 Total moving time of curtain This is a way for setting the total moving time of curtain manually.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 6000 No No No

Value

 

Description

0   The time depends on Moving Range Calibration
1   0.1s~600s

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Watt threshold The threshold is for PAN34 judging if the motor is running or not. The default value is 1 watt.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 5 No No No

Value

 

Description

1   The threshold is a judgment for motor running or not

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Watt differential Whenever the watt value varies over 5%, PAN34 will send the meter report to group 1 nodes. The default value is 1 (5%).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   It will not report Watt when change over 5%
1 (2)   It will report watt value when the di erential is over 5%

Parameter Number

Parameter Size

Parameter Name

Description

6 2 Timer offset for motor start running This parameter is an offset to count for starting time of the motor. It will improve the inaccurate when moving to the middle position. The default value is 50.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

50 0 255 No No No

Value

 

Description

0   0s ~ 2.55s, 50 = 0.5s