Z-Wave Products

There are over 4065 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Door/Window Sensor (ZSE41)

Z-Wave Certification Number: ZC12-21080282


Parameter Number

Parameter Size

Parameter Name

Description

1 1 LED Indicator Mode Turn the LED indicator for open/close status change on or off.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Value

 

Description

0   LED indicator won’t blink when the sensor’s status is changed from open to close and vice versa
1   LED indicator will blink when the sensor’s open/close status is changed (default)

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Battery report Battery report threshold %

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 1 50 No No No

Value

 

Description

1   %

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Low Battery Alarm Low battery alarm report

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

20 10 50 No No No

Value

 

Description

10   %

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Status Notification on Magnet Closure Decide which status should the sensor report to the hub when the magnet touches the sensor.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   closed status reported when the magnet is by the sensor (default)
1   open status reported when the magnet is by the sensor.

Parameter Number

Parameter Size

Parameter Name

Description

6 4 Group 2 ON report delay Set the delay before the sensor sends the ON basic set command to devices in Group 2 after the door is open.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3600 No No No

Value

 

Description

0   seconds

Parameter Number

Parameter Size

Parameter Name

Description

7 4 Group 2 OFF report delay Set the delay before the sensor sends the OFF basic set command to devices in Group 2 after the door is closed.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3600 No No No

Value

 

Description

0   seconds