There are over 4228 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | LED Indicator Mode | Choose whether you'd like the LED indicator to light up when water is detected. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | LED indicator doesn't light up when water is detected | ||||
1 | LED indicator lights up when water is detected | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 4 | Alarm Clear Delay | Set the delay for a "dry" report to be sent to the hub when water is no longer detected. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3600 | No | No | No |
Value |
Description |
||||
0 | seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Battery Reporting Threshold | Set the battery reporting threshold. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 1 | 50 | No | No | No |
Value |
Description |
||||
1 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Low Battery Alert | Set the battery level for a low battery alert to be sent to the hub. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
20 | 10 | 50 | No | No | No |
Value |
Description |
||||
10 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Group 2 ON/OFF Basic Set Commands | Choose when you'd like the sensor to send on/off basic set commands to Group 2 once the water detection status changes. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Doesn't send basic set commands | ||||
1 | Sends 0xFF (ON) when water is detected and 0x00 (OFF) when water is no longer detected | ||||
2 | Sends 0x00 (OFF) when water is detected and 0xFF (ON) when water is no longer detected | ||||