There are over 4228 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Water Sensor (ZSE42)

Z-Wave Certification Number: ZC12-21080294


Parameter Number

Parameter Size

Parameter Name

Description

1 1 LED Indicator Mode Choose whether you'd like the LED indicator to light up when water is detected.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Value

 

Description

0   LED indicator doesn't light up when water is detected
1   LED indicator lights up when water is detected

Parameter Number

Parameter Size

Parameter Name

Description

2 4 Alarm Clear Delay Set the delay for a "dry" report to be sent to the hub when water is no longer detected.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3600 No No No

Value

 

Description

0   seconds

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Battery Reporting Threshold Set the battery reporting threshold.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 1 50 No No No

Value

 

Description

1   %

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Low Battery Alert Set the battery level for a low battery alert to be sent to the hub.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

20 10 50 No No No

Value

 

Description

10   %

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Group 2 ON/OFF Basic Set Commands Choose when you'd like the sensor to send on/off basic set commands to Group 2 once the water detection status changes.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   Doesn't send basic set commands
1   Sends 0xFF (ON) when water is detected and 0x00 (OFF) when water is no longer detected