Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Parameter 10 | 1 (Default) |
room sensor | |
2 | floor sensor | ||||
3 | room+floor sensor | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Parameter 11 | -10 to 10 (Default) |
value is -5℃~5℃ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Parameter 12 | -10 to 10 (Default) |
value is -5℃~5℃ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Parameter 13 | 5 to 100 (Default) |
value is 5~100 minutes | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Parameter 14 | 0 | OFF | |
1 | Manual mode (comfort mode) | ||||
2 (Default) |
Auto mode (energy save mode) | ||||
3 | Away mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Parameter 16 | 0 | disable to report | |
2 to 10 (Default) |
report when the threshold value is 0.2℃ - 1℃ | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 2 | Parameter 17 | 0 | disable to report | |
30 to 28800 (Default) |
report when time interval value is 30~28800 s | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Parameter 18 | 0 | disable to report | |
1 to 100 (Default) |
report when absolute threshold is 1W~100W | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Parameter 19 | 0 | disable to report | |
1 to 10 (Default) |
report when absolute threshold is 0.1A~1A | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Parameter 2 | 0 | disable over current detection | |
5 to 16 (Default) |
over current detection max value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Parameter 20 | 0 | disable to report | |
1 to 10 (Default) |
report when absolute threshold is 1~10 V | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 4 | Parameter 21 | 60 to 2678400 (Default) |
value is 60~2678400 s | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Parameter 22 | 0 to 2 (Default) |
low level、mid level、high level | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | Parameter 23 | 0 (Default) |
indoor air temperature | |
1 | external temperature (floor temperature) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | Parameter 24 | -12 to 12 (Default) |
value is -12~12 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
26 | 1 | Parameter 26 | 0 (Default) |
disbaled | |
15 to 40 | the set temperature threshold | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Parameter 3 | 0 | disable vibration and buzzer | |
1 (Default) |
Low Level | ||||
2 | High Level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Parameter 4 | 0 | use default settings | |
1 (Default) |
recover to settings before power failure or power reset | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Parameter 6 | 0 | disable this function | |
20 to 60 (Default) |
air temperature over value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Parameter 7 | 5 to 20 (Default) |
hysteresis value : 0.5℃~2℃ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Parameter 8 | 0 (Default) |
use schedule set by user | |
1 | use Energy_Save_Heating temperature set by THERMOSTAT_SETPOINT_SET | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Parameter 9 | 1 (Default) |
NTC/10K B(25/50℃)=3950 | |
2 | NTC/15K B(25/50℃)=3950 | ||||
3 | NTC/50K B(25/50℃)=3950 | ||||
4 | NTC/100K B(25/50℃)=3950 | ||||