TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Zooz 4-in-1 Sensor 700 Series (ZSE40 700)

Z-Wave Certification Number: ZC12-21090312


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Temperature Scale Use this parameter to switch from Fahrenheit to Celsius scale.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Celsius
1   Fahrenheit

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Temperature Reporting Threshold Use it to set temperature change to be reported by the sensor (where 1 stands for 0.1 degree and 50 stands for 5 degrees).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

30 1 50 No No No

Value

 

Description

1   0.1 - 5 degrees

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Humidity Reporting Threshold Use it to set humidity percentage change to be reported by the sensor.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

20 1 50 No No No

Value

 

Description

1   %

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Light Reporting Threshold Use it to choose light percentage change to be reported by the sensor.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

25 5 50 No No No

Value

 

Description

5   %

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Motion Re-trigger Duration Use it to set trigger interval - the time when motion is reported again after initial trigger

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

15 15 255 No No No

Value

 

Description

15   seconds

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Motion Sensitivity Level Use it to adjust PIR sensor sensitivity, where 1 = very high sensitivity and 7 = very low sensitivity.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

4 1 7 No No No

Value

 

Description

1   1 = very high sensitivity and 7 = very low sensitivity

Parameter Number

Parameter Size

Parameter Name

Description

7 1 LED Indicator Mode Use it to choose between LED indicator modes.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 1 3 No No No

Value

 

Description

1   LED indicator is turned off (no visual notifications).
2   temperature and motion indicated with flashing light. Flashes every 3 minutes for temperature.
3   no indication for temperature, motion indicated with red flashing light.

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Retry Count Set 0~10 Retry Count, default:3

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 0 10 No No No

Value

 

Description

0   retries