There are over 4407 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Titan Water Valve Actuator (ZAC36)

Z-Wave Certification Number: ZC12-22010332


Parameter Number

Parameter Size

Parameter Name

Description

17 1 Water Valve Command and Reporting Behavior Decide which Z-Wave commands and reports you'd like to use to display when the device is open or closed (or to open / close the device). Default value: 1.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   reports on when the valve is open (opens the valve when an "on" report is sent from the hub), reports off when the valve is closed (closes the valve when an "off" report is sent from the hub)
1 (2)   reports off when the valve is open (opens the valve when an "off" report is sent from the hub), reports on when the valve is closed (closes the valve when an "on" report is sent from the hub)

Parameter Number

Parameter Size

Parameter Name

Description

18 1 Association Group 2 Reports (Open / Close) Decide which report is sent to Group 2 when parameter 17 is set to value 1 and the valve is closing.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Bit (Value)

 

Description

0 (1)   reports to Group 2 disabled
1 (2)   Basic Set on (default)
2 (4)   Basic Set off

Parameter Number

Parameter Size

Parameter Name

Description

19 1 Association Group 2 Reports (Open) Decide which report is sent to Group 2 when parameter 17 is set to value 1 and the valve is opening.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Bit (Value)

 

Description

0 (1)   reports to Group 2 disabled
1 (2)   Basic Set on
2 (4)   Basic Set off (default)

Parameter Number

Parameter Size

Parameter Name

Description

33 1 Temperature Reporting Unit Choose which scale you'd like the device to report temperature in.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Bit (Value)

 

Description

0 (1)   temperature reports disabled
1 (2)   Celsius
2 (4)   Fahrenheit (default)

Parameter Number

Parameter Size

Parameter Name

Description

34 2 Temperature Reporting Threshold Set the temperature reporting threshold.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

260 0 511 No No No

Value

 

Description

0   degrees

Parameter Number

Parameter Size

Parameter Name

Description

35 2 Temperature Report Offset Set the temperature reporting offset

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

256 0 4607 No No No

Value

 

Description

0   degrees

Parameter Number

Parameter Size

Parameter Name

Description

36 2 Overheat Trigger Value Set the overheat alarm trigger value. Default: 104.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

360 0 511 No No No

Value

 

Description

0   degrees

Parameter Number

Parameter Size

Parameter Name

Description

37 2 Overheat Recover value Set the overheat alarm cancellation trigger value. Default: 86.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

342 0 511 No No No

Value

 

Description

0   degrees

Parameter Number

Parameter Size

Parameter Name

Description

38 1 Association Group 4 Overheat Trigger Decide which report is sent to Group 4 when the overheat alarm (set in parameter 36) is triggered.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   reports to Group 4 disabled (default)
1 (2)   Basic Set on
2 (4)   Basic Set off

Parameter Number

Parameter Size

Parameter Name

Description

39 1 Association Group 4 Overheat Cancel Decide which report is sent to Group 4 when the overheat alarm is cancelled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   reports to Group 4 disabled (default)
1 (2)   Basic Set on
2 (4)   Basic Set off

Parameter Number

Parameter Size

Parameter Name

Description

40 2 Freeze Trigger Value Set the freeze alarm trigger value.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

288 0 511 No No No

Value

 

Description

0   degrees

Parameter Number

Parameter Size

Parameter Name

Description

41 2 Freeze Recover Value Set the freeze alarm cancellation trigger value. Default: 36.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

292 0 511 No No No

Value

 

Description

0   degrees

Parameter Number

Parameter Size

Parameter Name

Description

42 1 Freeze Alarm Operation Mode Decide if you want to allow the valve actuator to open and close during freeze alarm mode. If the actuator is disabled, it won't react to Z-Wave or manual triggers to open or close until the freeze alarm is cleared.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   operation disabled
1 (2)   operation enabled (default)

Parameter Number

Parameter Size

Parameter Name

Description

43 1 Association Group 5 Freeze Trigger Decide which report is sent to Group 5 when the freeze alarm (set in parameter 40) is triggered.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   reports to Group 5 disabled (default)
1 (2)   Basic Set on
2 (4)   Basic Set off

Parameter Number

Parameter Size

Parameter Name

Description

44 1 Association Group 5 Freeze Cancel Decide which report is sent to Group 5 when the freeze alarm is cancelled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   reports to Group 5 disabled (default)
1 (2)   Basic Set on
2 (4)   Basic Set off

Parameter Number

Parameter Size

Parameter Name

Description

49 1 Association Group 3 Water Leak Trigger Decide which report is sent to Group 3 when a leak alarm is triggered (from the connected leak detection probe). Values:

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Bit (Value)

 

Description

0 (1)   reports to Group 3 disabled
1 (2)   Basic Set on (default)
2 (4)   Basic Set off

Parameter Number

Parameter Size

Parameter Name

Description

50 1 Association Group 3 Water Leak Cancel Decide which report is sent to Group 3 when the leak alarm is cleared (water is no longer detected by the connected probe).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   reports to Group 3 disabled (default)
1 (2)   Basic Set on
2 (4)   Basic Set off
2 (4)   Basic Set off
2 (4)   Basic Set off

Parameter Number

Parameter Size

Parameter Name

Description

51 1 Water Leak Detection Valve Control Decide if you want to allow the valve actuator to open and close during a leak alarm event. If the actuator is disabled, it won't react to Z-Wave or manual triggers to open or close until the leak alarm is cleared.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   operation disabled
1 (2)   operation enabled (default)

Parameter Number

Parameter Size

Parameter Name

Description

65 1 Buzzer Decide if you'd like to receive sound (beep) feedback when operating the actuator as well as sound alarms for different modes and alarms the actuator goes into when installed.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   sound notifications disabled
1 (2)   sound notifications enabled (default)

Parameter Number

Parameter Size

Parameter Name

Description

66 1 LED Brightness Level Decide how bright you'd like the LED indicator to be on your actuator. If you set it to value 0, the LED indicator will be disabled. Default: 80.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

80 0 99 No No No

Value

 

Description

0   %

Parameter Number

Parameter Size

Parameter Name

Description

67 1 Z-Wave Button Lock Protection Enable Z-Wave button lock protection if you'd like to prevent the Z-Wave button from being locked accidentally.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Z-Wave button lock disabled (default)
1 (2)   Z-Wave button lock enabled

Parameter Number

Parameter Size

Parameter Name

Description

81 1 Notification Report Configure Notification Report (Bitmask)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

13 0 15 No No No