There are over 4407 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
17 | 1 | Water Valve Command and Reporting Behavior | Decide which Z-Wave commands and reports you'd like to use to display when the device is open or closed (or to open / close the device). Default value: 1. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | reports on when the valve is open (opens the valve when an "on" report is sent from the hub), reports off when the valve is closed (closes the valve when an "off" report is sent from the hub) | ||||
1 (2) | reports off when the valve is open (opens the valve when an "off" report is sent from the hub), reports on when the valve is closed (closes the valve when an "on" report is sent from the hub) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
18 | 1 | Association Group 2 Reports (Open / Close) | Decide which report is sent to Group 2 when parameter 17 is set to value 1 and the valve is closing. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | reports to Group 2 disabled | ||||
1 (2) | Basic Set on (default) | ||||
2 (4) | Basic Set off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
19 | 1 | Association Group 2 Reports (Open) | Decide which report is sent to Group 2 when parameter 17 is set to value 1 and the valve is opening. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | reports to Group 2 disabled | ||||
1 (2) | Basic Set on | ||||
2 (4) | Basic Set off (default) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
33 | 1 | Temperature Reporting Unit | Choose which scale you'd like the device to report temperature in. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | temperature reports disabled | ||||
1 (2) | Celsius | ||||
2 (4) | Fahrenheit (default) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
34 | 2 | Temperature Reporting Threshold | Set the temperature reporting threshold. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
260 | 0 | 511 | No | No | No |
Value |
Description |
||||
0 | degrees | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
35 | 2 | Temperature Report Offset | Set the temperature reporting offset | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
256 | 0 | 4607 | No | No | No |
Value |
Description |
||||
0 | degrees | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
36 | 2 | Overheat Trigger Value | Set the overheat alarm trigger value. Default: 104. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
360 | 0 | 511 | No | No | No |
Value |
Description |
||||
0 | degrees | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
37 | 2 | Overheat Recover value | Set the overheat alarm cancellation trigger value. Default: 86. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
342 | 0 | 511 | No | No | No |
Value |
Description |
||||
0 | degrees | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
38 | 1 | Association Group 4 Overheat Trigger | Decide which report is sent to Group 4 when the overheat alarm (set in parameter 36) is triggered. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | reports to Group 4 disabled (default) | ||||
1 (2) | Basic Set on | ||||
2 (4) | Basic Set off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
39 | 1 | Association Group 4 Overheat Cancel | Decide which report is sent to Group 4 when the overheat alarm is cancelled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | reports to Group 4 disabled (default) | ||||
1 (2) | Basic Set on | ||||
2 (4) | Basic Set off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
40 | 2 | Freeze Trigger Value | Set the freeze alarm trigger value. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
288 | 0 | 511 | No | No | No |
Value |
Description |
||||
0 | degrees | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
41 | 2 | Freeze Recover Value | Set the freeze alarm cancellation trigger value. Default: 36. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
292 | 0 | 511 | No | No | No |
Value |
Description |
||||
0 | degrees | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
42 | 1 | Freeze Alarm Operation Mode | Decide if you want to allow the valve actuator to open and close during freeze alarm mode. If the actuator is disabled, it won't react to Z-Wave or manual triggers to open or close until the freeze alarm is cleared. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | operation disabled | ||||
1 (2) | operation enabled (default) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
43 | 1 | Association Group 5 Freeze Trigger | Decide which report is sent to Group 5 when the freeze alarm (set in parameter 40) is triggered. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | reports to Group 5 disabled (default) | ||||
1 (2) | Basic Set on | ||||
2 (4) | Basic Set off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
44 | 1 | Association Group 5 Freeze Cancel | Decide which report is sent to Group 5 when the freeze alarm is cancelled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | reports to Group 5 disabled (default) | ||||
1 (2) | Basic Set on | ||||
2 (4) | Basic Set off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
49 | 1 | Association Group 3 Water Leak Trigger | Decide which report is sent to Group 3 when a leak alarm is triggered (from the connected leak detection probe). Values: | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | reports to Group 3 disabled | ||||
1 (2) | Basic Set on (default) | ||||
2 (4) | Basic Set off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
50 | 1 | Association Group 3 Water Leak Cancel | Decide which report is sent to Group 3 when the leak alarm is cleared (water is no longer detected by the connected probe). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | reports to Group 3 disabled (default) | ||||
1 (2) | Basic Set on | ||||
2 (4) | Basic Set off | ||||
2 (4) | Basic Set off | ||||
2 (4) | Basic Set off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
51 | 1 | Water Leak Detection Valve Control | Decide if you want to allow the valve actuator to open and close during a leak alarm event. If the actuator is disabled, it won't react to Z-Wave or manual triggers to open or close until the leak alarm is cleared. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | operation disabled | ||||
1 (2) | operation enabled (default) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
65 | 1 | Buzzer | Decide if you'd like to receive sound (beep) feedback when operating the actuator as well as sound alarms for different modes and alarms the actuator goes into when installed. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | sound notifications disabled | ||||
1 (2) | sound notifications enabled (default) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
66 | 1 | LED Brightness Level | Decide how bright you'd like the LED indicator to be on your actuator. If you set it to value 0, the LED indicator will be disabled. Default: 80. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
80 | 0 | 99 | No | No | No |
Value |
Description |
||||
0 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
67 | 1 | Z-Wave Button Lock Protection | Enable Z-Wave button lock protection if you'd like to prevent the Z-Wave button from being locked accidentally. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Z-Wave button lock disabled (default) | ||||
1 (2) | Z-Wave button lock enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
81 | 1 | Notification Report | Configure Notification Report (Bitmask) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
13 | 0 | 15 | No | No | No |