Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Association Capabilities

Model: Strips Comfort 700 (11 02 021)

Z-Wave Certification Number: ZC12-21120327


Group ID Group Profile Name Profile Maximum Nodes Description Endpoint ID Commands
1 Lifeline 0x0001 1 The Lifeline group, includes all commands that are sent automatically to keep a central controller notified of the status of Strips Comfort 700. This includes the battery level, the temperature and humidity levels, high and low temperature notifications, ambient light level reports and central scene notifications. 0
2 Binary Switch 0x2001 5 OFF – 00 (0x00) ON – 255 (0xFF) This association shall work for both Binary Switch and Timed Switch functions set in configuration parameter 29 – Slider switch function 0
3 Basic Set for Binary Switch 0x2001 5 OFF – 00 (0x00) ON – 255 (0xFF) Values could be modified using the configuration parameters 33 & 34 This association shall work for both Binary Switch and Timed Switch functions set in configuration parameter 29 – Slider switch function 0
4 Thermostat Mode Set for Binary Switch 0x2001 5 Pre-requisite: configuration parameter no. 29 – Slider switch function set to 1 (Binary Switch) OFF – 00 (0x00) or The value set in the configuration parameter 35, Default is Heat Mode On – 01 (0x01) 0
5 Temperature Report for Temperature Alarms 0x7104 5 Temperature Value 0
6 Basic Set for Temperature Alarms 0x7104 5 High temperature alarm = OFF – 00 (0x00) Low temperature alarm = ON – 255 (0xFF) Values could be modified using the configuration parameters 36 & 37 0
7 Basic Set for Ambient Light Report Levels 0x3103 5 High ambient light (LUX) level trigger = ON – 255 (0xFF) Low ambient light (LUX) level trigger = OFF – 00 (0x00) Values could be modified using the configuration parameters 38 & 39 0