Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 4 | High ambient light (LUX) level trigger | The sensor will send a light report when the light rises above this level. Can be used in scenarios to trigger other devices. When enabling parameter 10, parameter 11 must also be set with a lower value, else the trigger stays off | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 64000 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Off | |||
20 | 64000 | LUX | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 4 | Low ambient light (LUX) level trigger | The sensor will send a light report when the light goes below this level. Can be used in scenarios to trigger other devices. When enabling parameter 11, parameter 10 must also be set with a greater value, else the trigger stays off | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 42000 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Off | |||
10 | 42000 | LUX | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | LED alarm event reporting | Turn On or Off LED for specific event indications (ex. alarms) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Off | ||||
1 (2) | On, but no LED indication for associated nodes (1/5 blinks) | ||||
2 (4) | On with LED indications based on success/fail for BOTH the gateway and the associated nodes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
25 | 2 | Temperature and Humidity reporting time (Activat | Select the number of minutes between reports (15 mins to 24 hrs) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 15 | 1440 | No | No | No |
Value |
Description |
||||
15 | Minutes between reports (periodic reporting) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
26 | 1 | Temperature change for next report (Activated i | Temperature must change by this value for new a report Default: "20 ( = 2.0 C) or 30 (= 3.0 F for US frequency)" | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
20 | 5 | 100 | No | No | No |
Value |
Description |
||||
5 | Input value converted to one decimal place [= 0.5 to 10.0 (degree C/F) ] | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
28 | 1 | Humidity change for next report (Activated in p | Humidity must change by this value for a new report | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 2 | 10 | No | No | No |
Value |
Description |
||||
2 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
29 | 1 | Slider switch function | Select if the switch should act as a binary switch or a timed switch. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 2 | No | No | Yes |
Bit (Value) |
Description |
||||
1 (2) | Binary Switch | ||||
2 (4) | Timed Switch | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
30 | 1 | Timed Switch duration | Select the duration that should trigger the opposite state of the Switch (if 2 is selected in parameter 29) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 60 | No | No | Yes |
Value |
Description |
||||
1 | minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
31 | 1 | Use Multi-Command encapsulation | Send Temperature and Humidity sensor value reports and or Temperature Alarms related reports (Notification Report + Multi-Level Sensor Report + Central Scene Notification) in one message, this saves battery power. Make sure your gateway supports Multi-Command Command Class first. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | Yes |
Bit (Value) |
Description |
||||
0 (1) | Off | ||||
1 (2) | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
32 | 1 | Use Central Scene Notifications | Central Scene Notifications are sent for the Slider Switch state change, High and Low Temperature Alarms and High and Low Ambient Light states. Scenes could be configured in the gateway. Scenes allow multiple devices to be controlled by a single Z-Wave command. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | Yes |
Bit (Value) |
Description |
||||
0 (1) | Off | ||||
1 (2) | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
33 | 1 | Basic Set value sent to Association group 3 when | This parameter defines the value sent to the devices in the Association group 3 (using Basic Command Class). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | Yes |
Value |
Description |
||||
0 | Basic Set value sent to Association group 3 when the slider switch is on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
34 | 1 | Basic Set value sent to Association group 3 when | This parameter defines the value sent to the devices in the Association group 3 (using Basic Command Class). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | Yes |
Value |
Description |
||||
0 | Basic Set value sent to Association group 3 when the slider switch is off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
35 | 1 | Thermostat mode for Association group 4 on Binar | This config parameter defines the value sent to the devices in the Association group 4 (using Thermostat Mode Command Class). Refer the Thermostat modes supported by the associated node | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 13 | No | No | Yes |
Value |
Description |
||||
1 | Thermostat mode for Association group 4 when the slider switch is on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
36 | 1 | Basic Set value sent to Association group 6 on H | This config parameter defines the value sent to the devices in the Association group 6 (using Basic Command Class) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | Yes |
Value |
Description |
||||
0 | Basic Set value sent to Association group 6 on High Temperature Alarm | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
37 | 1 | Basic Set value sent to Association group 6 on L | This config parameter defines the value sent to the devices in the Association group 6 (using Basic Command Class) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | Yes |
Value |
Description |
||||
0 | Basic Set value sent to Association group 6 on Low Temperature Alarm | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
38 | 1 | Basic Set value sent to the Association group 7 | This config parameter defines the value sent to the devices in the Association group 7 (using Basic Command Class) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | Yes |
Value |
Description |
||||
0 | Basic Set value sent to the Association group 7 on High ambient light level report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
39 | 1 | Basic Set value sent to the Association group 7 | This config parameter defines the value sent to the devices in the Association group 7 (using Basic Command Class) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | Yes |
Value |
Description |
||||
0 | Basic Set value sent to the Association group 7 on Low ambient light level report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Temperature & Humidity reporting | Select temperature and humidity sensor reporting | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Off | ||||
1 (2) | On. Sends temperature/humidity based on difference from last reported value (set in config parameters 26 and 28) | ||||
2 (4) | On. Timed reporting of the actual temperature and the actual humidity value (set time in config parameter 25) | ||||
3 (8) | On. Timed reporting of the average temperature value between reports. Will also send the actual humidity value (set time in config parameter 25) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Temperature unit | Select the temperature unit Default: 0 (Except US frequency) or 1 (US frequency) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Celcius | ||||
1 (2) | Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Temperature alarms | Turn On or Off temperature alarm (The alarms are not affected by parameters 4, 25 or 26) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Off | ||||
1 (2) | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 2 | High temperature alarm level | Select high temperature alarm level "-20 to +80 (degree C) or -4 to +176 (degree F) (US frequency)" Default: "40 C or 104 F (US frequency)" | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
104 | -4 | 176 | No | No | No |
From |
To |
Description |
|||
-4 | 176 | (degree F) (US frequency) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 2 | Low temperature alarm level | Select low temperature alarm level "-20 to +60 (degree C) or -4 to +140 (degree F) (US frequency)" Default: "5 C or 41 F (US frequency)" | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
41 | -4 | 140 | No | No | No |
From |
To |
Description |
|||
-4 | 140 | (degree F) (US frequency) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Ambient light reporting | Ambient light report settings. Using a filter (low-pass) is highly recommended to avoid large amounts of reports in fluctuating lights. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
8 | 0 | 8 | No | No | No |
Value |
Description |
||||
0 | Off | ||||
1 | Reporting visual changes without filter (This configuration will affect the sensor battery life if placed where light fluctuates significantly) | ||||
2 | Filter length. 2 is the fastest filter allowing quick responses. 8 is a slower filter setting and will give the longest battery life | ||||