TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Parameter no. 1 – In-wall Switch Type for Load ( ) to control terminal I | 0 (Default) |
momentary switch | |
1 | on/off toggle switch | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Parameter no. 11 - Turn Load ( ) Off Automatically with Timer | 0 (Default) |
Auto OFF Disabled | |
1 to 32536 | 1 - 32536 seconds - Auto OFF timer enabled for a given amount of seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Parameter no. 12 - Turn Load ( ) On Automatically with Timer | 0 (Default) |
Auto ON Disabled | |
1 to 32536 | 1 - 32536 seconds - Auto ON timer enabled for a given amount of seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Parameter no. 21 - Enable/Disable the Double click function | 0 (Default) |
double click disabled | |
1 | double click enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | Parameter no. 30 - Restore on/off status for load after power failure | 0 (Default) |
Device saves last on/off status and restores it after a power failure. | |
1 | Device does not save on/off status and does not restore it after a power failure, it remains off. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Parameter no. 40 – Watt Power Consumption Reporting Threshold for Load | 0 | Power consumption reporting disabled | |
1 to 100 (Default) |
= 1 % - 100 % Power consumption reporting enabled. New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1 % (the lowest value possible). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 2 | Parameter no. 42 – Watt Power Consumption Reporting Time Threshold for Load | 0 (Default) |
Power consumption reporting on time interval disabled | |
30 to 32767 | 30 - 32767seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Parameter no. 5 – Working mode | 0 (Default) |
Dimmer mode | |
1 | Switch mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 1 | Parameter no. 60 – Minimum dimming value | 0 to 98 (Default) |
1 % - 98 %, step is 1 %. Minimum dimming value is set by entering a value. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 1 | Parameter no. 61 – Maximum dimming value | 1 to 99 (Default) |
2 % - 99 %, step is 1 %. Maximum dimming value is set by entering a value | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
65 | 1 | Parameter no. 65 – Dimming time when key pressed (soft on/off) | 1 to 127 (Default) |
1 seconds- 127 seconds, step is 1 second | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 2 | Parameter no. 66 – Dimming time when key holdwag | 1 to 127 (Default) |
1 second – 127 seconds | |
128 to 253 | 1 minute – 126 minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
67 | 1 | Parameter no. 67 – Ignore start level | 0 (Default) |
use the start level value | |
1 | ignore the start level value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
68 | 1 | Parameter no. 68 – Dimming duration for associations | 1 to 127 | (from 1 to 127 seconds) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
70 | 2 | Parameter no. 70 - Overload safety switch | 0 | function not active | |
1 to 200 (Default) |
1 W – 200 W | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
71 | 1 | Parameter no. 71 – Calibration trigger | 1 | calibration done after power cycle regardless of inclusion status | |
2 | force calibration. Calibration will start immediately | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
72 | 1 | Parameter no. 72 – Calibration status (read only) | 1 | calibration was successful | |
2 (Default) |
calibration failed | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
73 | 1 | Parameter no. 73 – Alarm/Notification events | 1 | turn ON | |
2 | turn OFF | ||||
3 | start blinking (output turns 1 s ON, and 1 s OFF) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
74 | 1 | Parameter no. 74 – Alarm/Notification time interval (dependant on parameter 73) | 1 to 125 (Default) |
1 -125 minutes | |