There are over 4401 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: ZOE SHUTTER H (HZ07100)

Z-Wave Certification Number: ZC10-22017068


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Activate/deactivate functions ALL ON / ALL OFF 0 ALL ON is not active ALL OFF is not active
  1 ALL ON is not active ALL OFF active
  2 ALL ON active ALL OFF is not active
  255
(Default)
ALL ON active, ALL OFF active.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 2 Temperature sensor offset settings 1 to 100 Where 1 stands for 0.1°C and 100 stands for 10.0°C added to the actual measurement.
  1001 to 1100 Where 1001 stands for -0.1°C and 1100 stands for -10.0°C subtracted from the actual measurement.
  32536
(Default)
offset is 0.0C

Parameter Number

Parameter Size

Parameter Name

Parameter Values

120 1 Parameter no. 120 – Temperature Sensor Reporting Threshold 0 Reporting disabled
  1 to 127
(Default)
Where 1 stands for 0.1°C and 127 stands for 12.7°C.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 - Power reporting in Watts on power change for Q1 or Q2 0 reporting disabled
  1 to 100
(Default)
1% - 100% Power consumption reporting enabled. New value is reported only when the power consumption in real time changes by more than the percentage value set in this parameter, compared to the previous power consumption reading, starting at 1% (the lowest value possible).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 2 Power reporting in Watts by time interval for Q1 or Q2 0
(Default)
Power consumption reporting disabled
  1 to 32767 1 - 32767 seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here

Parameter Number

Parameter Size

Parameter Name

Parameter Values

71 1 Operating modes 0
(Default)
Shutter mode
  1 Venetian mode (up/down and slate rotation)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

72 2 Slats tilting full turn time 0 tilting time disabled
  1 to 32767
(Default)
0,01seconds - 327,67 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

73 1 Slats position 0 Slats return to the previously set position only after being activated via the Z-Wave gateway (hub) (not valid for limit switch positions)
  1
(Default)
Slats return to the previously set position in case they were activated via the Z-Wave gateway (hub), push-button operation or when the lower limit switch is reached

Parameter Number

Parameter Size

Parameter Name

Parameter Values

74 2 Motor moving up/down time 0
(Default)
moving time disabled (working with limit switches)
  1 to 32676 0.1 seconds – 3276.7 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

76 1 Motor operation detection 0 The value 0 means that reaching a limit switch will not be detected.
  1 to 127
(Default)
1 - 127W The value 0 means reaching a limit switch will not be detected.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

78 1 Forced Shutter calibration 0 to 1
(Default)
Start calibration process (when calibration process is finished, completing full cycle - up, down and up, set the parameter 78 (Forced Shutter calibration) value back to 0.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

85 1 Power consumption max delay time 0 time is set automatically
  3 to 50
(Default)
0,3seconds - 5seconds (100ms resolution)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

90 1 Time delay for next motor movement 1 to 30
(Default)
0.1seconds - 3seconds (100ms resolution)
  5
(Default)
500ms