There are over 4401 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Activate/deactivate functions ALL ON / ALL OFF | 0 | ALL ON is not active ALL OFF is not active | |
1 | ALL ON is not active ALL OFF active | ||||
2 | ALL ON active ALL OFF is not active | ||||
255 (Default) |
ALL ON active, ALL OFF active. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
110 | 2 | Temperature sensor offset settings | 1 to 100 | Where 1 stands for 0.1°C and 100 stands for 10.0°C added to the actual measurement. | |
1001 to 1100 | Where 1001 stands for -0.1°C and 1100 stands for -10.0°C subtracted from the actual measurement. | ||||
32536 (Default) |
offset is 0.0C | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
120 | 1 | Parameter no. 120 – Temperature Sensor Reporting Threshold | 0 | Reporting disabled | |
1 to 127 (Default) |
Where 1 stands for 0.1°C and 127 stands for 12.7°C. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | - Power reporting in Watts on power change for Q1 or Q2 | 0 | reporting disabled | |
1 to 100 (Default) |
1% - 100% Power consumption reporting enabled. New value is reported only when the power consumption in real time changes by more than the percentage value set in this parameter, compared to the previous power consumption reading, starting at 1% (the lowest value possible). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 2 | Power reporting in Watts by time interval for Q1 or Q2 | 0 (Default) |
Power consumption reporting disabled | |
1 to 32767 | 1 - 32767 seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
71 | 1 | Operating modes | 0 (Default) |
Shutter mode | |
1 | Venetian mode (up/down and slate rotation) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
72 | 2 | Slats tilting full turn time | 0 | tilting time disabled | |
1 to 32767 (Default) |
0,01seconds - 327,67 seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
73 | 1 | Slats position | 0 | Slats return to the previously set position only after being activated via the Z-Wave gateway (hub) (not valid for limit switch positions) | |
1 (Default) |
Slats return to the previously set position in case they were activated via the Z-Wave gateway (hub), push-button operation or when the lower limit switch is reached | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
74 | 2 | Motor moving up/down time | 0 (Default) |
moving time disabled (working with limit switches) | |
1 to 32676 | 0.1 seconds – 3276.7 seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
76 | 1 | Motor operation detection | 0 | The value 0 means that reaching a limit switch will not be detected. | |
1 to 127 (Default) |
1 - 127W The value 0 means reaching a limit switch will not be detected. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
78 | 1 | Forced Shutter calibration | 0 to 1 (Default) |
Start calibration process (when calibration process is finished, completing full cycle - up, down and up, set the parameter 78 (Forced Shutter calibration) value back to 0. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
85 | 1 | Power consumption max delay time | 0 | time is set automatically | |
3 to 50 (Default) |
0,3seconds - 5seconds (100ms resolution) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
90 | 1 | Time delay for next motor movement | 1 to 30 (Default) |
0.1seconds - 3seconds (100ms resolution) | |
5 (Default) |
500ms | ||||