Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Minimum brightness level | 1 to 98 (Default) |
percentage level of brightness | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Timer functionality (auto - off) | 0 to 32767 (Default) |
Timer functionality (auto - off) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | ALL ON/ALL OFF function | 0 to 255 (Default) |
ALL ON/ALL OFF function | |
0 to 255 (Default) |
ALL ON/ALL OFF function | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Force auto-calibration | 0 to 2 (Default) |
Force auto-calibration | |
0 to 2 (Default) |
Force auto-calibration | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Auto-calibration status (read-only parameter) | 0 to 1 (Default) |
Auto-calibration status (read-only parameter) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Burnt out bulb detection | 0 to 99 (Default) |
Burnt out bulb detection | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | Time delay of a burnt out bulb (parameter 15) or overload (parameter 39) detection | 0 to 255 (Default) |
Time delay of a burnt out bul | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Forced switch on brightness level | 0 to 99 (Default) |
Forced switch on brightness level | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Switch type | 0 to 2 (Default) |
Choose between momentary | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | The value sent to associated devices on single click | 0 to 1 (Default) |
The value sent to associated devices on single click | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Assign toggle switch status to the device status | 0 to 1 (Default) |
Assign toggle switch status to the device status | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Maximum brightness level | 2 to 99 (Default) |
percentage level of brightness | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Double click option - set the brightness level to MAX | 0 to 1 (Default) |
Double click option - set the brightness level to MAX | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Command frames sent in 2nd and 3rd association groups (S1 associations) | 0 to 16 (Default) |
Command frames sent in 2nd and 3rd association groups (S1 associations) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Command frames sent in 4th and 5th association groups (S2 associations) | 0 to 16 (Default) |
Command frames sent in 4th and 5th association groups | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | The function of 3-way switch | 0 to 1 (Default) |
The function of 3-way switch | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | Associations in Z-Wave network security mode | 0 to 15 (Default) |
Associations in Z-Wave network security mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
25 | 1 | Scene activation functionality | 0 to 1 (Default) |
Scene activation functionality | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
26 | 1 | Switch functionality of S1 and S2 | 0 to 1 (Default) |
Switch functionality of S1 and S2 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Load control mode | 0 to 2 (Default) |
Load control mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
28 | 1 | Load control mode recognized during auto-calibration (read only | 0 to 1 (Default) |
Load control mode recognized during auto-calibration | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
29 | 1 | On/Off mode | 0 to 2 (Default) |
On/Off mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | . Incandescence level of dimmable compact fluorescent lamps | 1 to 99 (Default) |
percentage level of brightness | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | Dimmability of the load | 0 to 1 (Default) |
Dimmability of the load | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
31 | 1 | Soft-Start functionality | 0 to 2 (Default) |
Soft-Start functionality | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
32 | 1 | Auto-calibration after power on | 0 to 4 (Default) |
Auto-calibration after power on | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
33 | 1 | Behaviour of Dimmer-Control after OVERCURRENT or SURGE | 0 to 1 (Default) |
Behaviour of Dimmer-Control after OVERCURRENT or SURGE | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
34 | 2 | Brightness level correction for flickering loads | 0 to 255 (Default) |
Brightness level correction for flickering loads | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
35 | 2 | Power limit - OVERLOAD | 0 to 350 (Default) |
Power limit - OVERLOAD | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
36 | 1 | Response to General Purpose Alarm | 0 to 3 (Default) |
Response to General Purpose Alarm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
37 | 1 | Response to Water Flooding Alarm | 0 to 3 (Default) |
Response to Water Flooding Alarm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
38 | 1 | Response to Smoke, CO or CO2 Alarm | 0 to 3 (Default) |
Response to Smoke, CO or CO2 Alarm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
39 | 1 | Response to Temperature Alarm | 0 to 3 (Default) |
Response to Temperature Alarm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 2 | Incandescence time of dimmable compact fluorescent lamps | 1 to 25 | time of dimmable compact fluorescent lamps | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 2 | Time of alarm state | 1 to 32767 (Default) |
Time of alarm state | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 1 | OVERLOAD alarm report (load power consumption too high) | 0 to 1 (Default) |
OVERLOAD alarm report | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 1 | LOAD ERROR alarm report (no load, load failure, burnt out bulb) | 0 to 1 (Default) |
LOAD ERROR alarm report | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
43 | 1 | OVERCURRENT alarm report (short circuit, burnt out bulb causing overcurrent) | 0 to 1 (Default) |
OVERCURRENT alarm report | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
44 | 1 | SURGE alarm report (Dimmer-Control output overvoltage) | 0 to 1 (Default) |
SURGE alarm report | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
45 | 1 | OVERHEAT (critical temperature) and VOLTAGE DROP (low voltage) alarm report | 0 to 1 (Default) |
OVERHEAT (critical temperature) and VOLTAGE DROP | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
46 | 1 | Active power reports | 0 to 100 (Default) |
Active power reports | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
47 | 2 | Periodic active power and energy reports | 0 to 32767 (Default) |
Periodic active power and energy reports | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
48 | 2 | Energy reports | 0 to 255 (Default) |
Energy reports | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
49 | 1 | Self-measurement | 0 to 1 (Default) |
Self-measurement | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Automatic control - dimming step size | 1 to 99 | dimming step percentage value | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
50 | 1 | Method of calculating the active power | 0 to 2 (Default) |
Method of calculating the active power | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
51 | 2 | Approximated power at the maximum brightness level | 0 to 500 (Default) |
Approximated power at the maximum brightness level | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Automatic control - time of a dimming step | 0 to 255 (Default) |
time of a dimming step | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Manual control - dimming step size | 1 to 99 (Default) |
dimming step percentage value | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Manual control - time of a dimming step | 0 to 255 (Default) |
time of a dimming step | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | State of the device after a power failure | 0 to 1 (Default) |
state before power failure. | |