TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Door/window state | 0 to 1 (Default) |
Door/window state | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Tamper - reporting alarm cancellation | 0 to 1 (Default) |
Tamper - reporting alarm cancellation | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Interval of temperature measurements | 0 to 32400 (Default) |
Interval of temperature measurements | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Temperature reports threshold | 0 to 300 (Default) |
Temperature reports threshold | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 2 | Interval of temperature reports | 0 to 32400 (Default) |
Interval of temperature reports | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 2 | Temperature offset | -1000 to 1000 (Default) |
Temperature offset | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Temperature alarm reports | 0 to 3 (Default) |
Temperature alarm reports | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 2 | High temperature alarm threshold | 1 to 600 (Default) |
High temperature alarm threshold | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 2 | Low temperature alarm threshold | 0 to 599 (Default) |
Low temperature alarm threshold | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Visual LED indications | 1 to 6 (Default) |
Visual LED indications | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Associations in Z-Wave network Security Mode | 0 to 3 (Default) |
Associations in Z-Wave network Security Mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | 2nd association group triggers | 0 to 2 (Default) |
2nd association group triggers | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 2 | Association for opening - value sent | 0 to 255 (Default) |
Association for opening - value sent | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Association for closing - value sent | 0 to 255 (Default) |
Association for closing - value sent | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 2 | Association for opening - time delay | 0 to 32400 (Default) |
Association for opening - time delay | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Association for closing - time delay | 0 to 32400 (Default) |
Association for closing - time delay | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 2 | Tamper - alarm cancellation delay | 0 to 32400 (Default) |
Tamper - alarm cancellation delay | |