There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: RGBW-Control (FGRGBW-442)

Z-Wave Certification Number: ZC10-22047077


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Remember device status before the power failure 0
(Default)
device remains switched off
  1 device restores the state from before the power failure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

150 1 Inputs - LED colour control mode 0
(Default)
RGBW mode (every input controls output with the same number, IN1‑OUT1, IN2‑OUT2, IN3‑OUT3, IN4‑OUT4)
  1 HSB and White mode (inputs works in HSB color model, IN1‑H (Hue), IN2‑S (Saturation), IN3‑B (Brightness), IN4‑White (OUT4)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

151 2 Local control - transition time 0 instantly
  1 to 127
(Default)
1 s - 127 s, 1 s step
  128 to 254 1 min - 127 min, 1 min step

Parameter Number

Parameter Size

Parameter Name

Parameter Values

152 2 Remote control - transition time 0
(Default)
instantly
  1 to 127 1 s - 127 s, 1 s step
  128 to 254 1 min - 127 min, 1 min step

Parameter Number

Parameter Size

Parameter Name

Parameter Values

154 4 ON frame value for single click 0 to 99 value for every byte (MSB to LSB)
  255 value for every byte (MSB to LSB)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

155 4 OFF frame value for single click 0 to 99
(Default)
value for every byte (MSB to LSB)
  255 value for every byte (MSB to LSB)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

156 4 ON frame value for double click 0 to 99 value for every byte (MSB to LSB)
  255 value for every byte (MSB to LSB)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

157 1 Start programmed sequence 0
(Default)
sequence inactive
  1 to 5 user-defined sequence
  6 Fireplace sequence
  7 Storm sequence
  8 Rainbow sequence
  9 Aurora sequence
  10 Police (red-white-blue) sequence

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Input 1 - operating mode 0 Analog input without internal pull-up (Sensor Multilevel)
  1 Analog input with internal pull-up (Sensor Multilevel)
  2
(Default)
Momentary switch (Central Scene)
  3 Toggle switch: switch state on every input change (Central Scene)
  4 Toggle switch: contact closed – ON, contact opened – OFF (Central Scene)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Input 2 - operating mode 0 Analog input without internal pull-up (Sensor Multilevel)
  1 Analog input with internal pull-up (Sensor Multilevel)
  2
(Default)
Momentary switch (Central Scene)
  3 Toggle switch: switch state on every input change (Central Scene)
  4 Toggle switch: contact closed – ON, contact opened – OFF (Central Scene)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Input 3 - operating mode 0 Analog input without internal pull-up (Sensor Multilevel)
  1 Analog input with internal pull-up (Sensor Multilevel)
  2
(Default)
Momentary switch (Central Scene)
  3 Toggle switch: switch state on every input change (Central Scene)
  4 Toggle switch: contact closed – ON, contact opened – OFF (Central Scene)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Input 4 - operating mode 0 Analog input without internal pull-up (Sensor Multilevel)
  1 Analog input with internal pull-up (Sensor Multilevel)
  2
(Default)
Momentary switch (Central Scene)
  3 Toggle switch: switch state on every input change (Central Scene)
  4 Toggle switch: contact closed – ON, contact opened – OFF (Central Scene)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 4 Alarm configuration - 1st slot 0 to 255
(Default)
[LSB] – Action
  256 to 65535 Event/State Parameters
  65536 to 16777215 Notification Status
  16777216 to 2147483647 [MSB] – Notification Type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 4 Alarm configuration - 2nd slot 0 to 255 [LSB] – Action
  256 to 65535 Event/State Parameters
  65536 to 16777215 Notification Status
  16777216 to 2147483647
(Default)
[MSB] – Notification Type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 4 Alarm configuration - 3rd slot 0 to 255 [LSB] – Action
  256 to 65535 Event/State Parameters
  65536 to 16777215 Notification Status
  16777216 to 2147483647
(Default)
[MSB] – Notification Type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

33 4 Alarm configuration - 4th slot 0 to 255 [LSB] – Action
  256 to 65535 Event/State Parameters
  65536 to 16777215 Notification Status
  16777216 to 2147483647
(Default)
[MSB] – Notification Type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

34 4 Alarm configuration - 5th slot 0 to 255 [LSB] – Action
  256 to 65535 Event/State Parameters
  65536 to 16777215 Notification Status
  16777216 to 2147483647
(Default)
[MSB] – Notification Type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

35 2 Duration of alarm signalization 0
(Default)
infinite signalization
  1 to 32400 (1s-9h, 1s step)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Input 1 - sent scenes 1 Key pressed 1 time
  2 Key pressed 2 times
  4 Key pressed 3 times
  8 Key held down and key released
  0 No scenes sent
  15
(Default)
All scenes sent

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 Input 2 - sent scenes 0 No scenes sent
  1 Key pressed 1 time
  2 Key pressed 2 times
  4 Key pressed 3 times
  8 Key held down and key released
  15
(Default)
All scenes sent

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 1 Input 3 - sent scenes 0 No scenes sent
  1 Key pressed 1 time
  2 Key pressed 2 times
  4 Key pressed 3 times
  8 Key held down and key released
  15
(Default)
All scenes sent

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 1 Input 4 - sent scenes 0 No scenes sent
  1 Key pressed 1 time
  2 Key pressed 2 times
  4 Key pressed 3 times
  8 Key held down and key released
  15
(Default)
All scenes sent

Parameter Number

Parameter Size

Parameter Name

Parameter Values

62 2 Power reports - periodic 0 periodic reports are disabled
  30 to 32400
(Default)
(30 - 32400 s) - report interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

63 2 Analog inputs reports and output change on input change 0 reporting on change disabled
  1 to 100
(Default)
0.1 - 10 V, 0.1 V step

Parameter Number

Parameter Size

Parameter Name

Parameter Values

64 2 Analog inputs reports - periodic 0
(Default)
periodical reports disabled
  30 to 32400 30 - 32400 s, 1 s step

Parameter Number

Parameter Size

Parameter Name

Parameter Values

65 2 Energy reports - on change 0 reports are disabled
  1 to 500
(Default)
(0.01 - 5 kWh) - change in energy

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 Energy reports - periodic 0 periodic reports are disabled
  30 to 32400
(Default)
(30 - 32400 s) - report interval