There are over 4409 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Remember device status before the power failure | 0 (Default) |
device remains switched off | |
1 | device restores the state from before the power failure | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
150 | 1 | Inputs - LED colour control mode | 0 (Default) |
RGBW mode (every input controls output with the same number, IN1‑OUT1, IN2‑OUT2, IN3‑OUT3, IN4‑OUT4) | |
1 | HSB and White mode (inputs works in HSB color model, IN1‑H (Hue), IN2‑S (Saturation), IN3‑B (Brightness), IN4‑White (OUT4) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
151 | 2 | Local control - transition time | 0 | instantly | |
1 to 127 (Default) |
1 s - 127 s, 1 s step | ||||
128 to 254 | 1 min - 127 min, 1 min step | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
152 | 2 | Remote control - transition time | 0 (Default) |
instantly | |
1 to 127 | 1 s - 127 s, 1 s step | ||||
128 to 254 | 1 min - 127 min, 1 min step | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
154 | 4 | ON frame value for single click | 0 to 99 | value for every byte (MSB to LSB) | |
255 | value for every byte (MSB to LSB) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
155 | 4 | OFF frame value for single click | 0 to 99 (Default) |
value for every byte (MSB to LSB) | |
255 | value for every byte (MSB to LSB) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
156 | 4 | ON frame value for double click | 0 to 99 | value for every byte (MSB to LSB) | |
255 | value for every byte (MSB to LSB) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
157 | 1 | Start programmed sequence | 0 (Default) |
sequence inactive | |
1 to 5 | user-defined sequence | ||||
6 | Fireplace sequence | ||||
7 | Storm sequence | ||||
8 | Rainbow sequence | ||||
9 | Aurora sequence | ||||
10 | Police (red-white-blue) sequence | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Input 1 - operating mode | 0 | Analog input without internal pull-up (Sensor Multilevel) | |
1 | Analog input with internal pull-up (Sensor Multilevel) | ||||
2 (Default) |
Momentary switch (Central Scene) | ||||
3 | Toggle switch: switch state on every input change (Central Scene) | ||||
4 | Toggle switch: contact closed – ON, contact opened – OFF (Central Scene) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Input 2 - operating mode | 0 | Analog input without internal pull-up (Sensor Multilevel) | |
1 | Analog input with internal pull-up (Sensor Multilevel) | ||||
2 (Default) |
Momentary switch (Central Scene) | ||||
3 | Toggle switch: switch state on every input change (Central Scene) | ||||
4 | Toggle switch: contact closed – ON, contact opened – OFF (Central Scene) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Input 3 - operating mode | 0 | Analog input without internal pull-up (Sensor Multilevel) | |
1 | Analog input with internal pull-up (Sensor Multilevel) | ||||
2 (Default) |
Momentary switch (Central Scene) | ||||
3 | Toggle switch: switch state on every input change (Central Scene) | ||||
4 | Toggle switch: contact closed – ON, contact opened – OFF (Central Scene) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | Input 4 - operating mode | 0 | Analog input without internal pull-up (Sensor Multilevel) | |
1 | Analog input with internal pull-up (Sensor Multilevel) | ||||
2 (Default) |
Momentary switch (Central Scene) | ||||
3 | Toggle switch: switch state on every input change (Central Scene) | ||||
4 | Toggle switch: contact closed – ON, contact opened – OFF (Central Scene) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 4 | Alarm configuration - 1st slot | 0 to 255 (Default) |
[LSB] – Action | |
256 to 65535 | Event/State Parameters | ||||
65536 to 16777215 | Notification Status | ||||
16777216 to 2147483647 | [MSB] – Notification Type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
31 | 4 | Alarm configuration - 2nd slot | 0 to 255 | [LSB] – Action | |
256 to 65535 | Event/State Parameters | ||||
65536 to 16777215 | Notification Status | ||||
16777216 to 2147483647 (Default) |
[MSB] – Notification Type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
32 | 4 | Alarm configuration - 3rd slot | 0 to 255 | [LSB] – Action | |
256 to 65535 | Event/State Parameters | ||||
65536 to 16777215 | Notification Status | ||||
16777216 to 2147483647 (Default) |
[MSB] – Notification Type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
33 | 4 | Alarm configuration - 4th slot | 0 to 255 | [LSB] – Action | |
256 to 65535 | Event/State Parameters | ||||
65536 to 16777215 | Notification Status | ||||
16777216 to 2147483647 (Default) |
[MSB] – Notification Type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
34 | 4 | Alarm configuration - 5th slot | 0 to 255 | [LSB] – Action | |
256 to 65535 | Event/State Parameters | ||||
65536 to 16777215 | Notification Status | ||||
16777216 to 2147483647 (Default) |
[MSB] – Notification Type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
35 | 2 | Duration of alarm signalization | 0 (Default) |
infinite signalization | |
1 to 32400 | (1s-9h, 1s step) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Input 1 - sent scenes | 1 | Key pressed 1 time | |
2 | Key pressed 2 times | ||||
4 | Key pressed 3 times | ||||
8 | Key held down and key released | ||||
0 | No scenes sent | ||||
15 (Default) |
All scenes sent | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 1 | Input 2 - sent scenes | 0 | No scenes sent | |
1 | Key pressed 1 time | ||||
2 | Key pressed 2 times | ||||
4 | Key pressed 3 times | ||||
8 | Key held down and key released | ||||
15 (Default) |
All scenes sent | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 1 | Input 3 - sent scenes | 0 | No scenes sent | |
1 | Key pressed 1 time | ||||
2 | Key pressed 2 times | ||||
4 | Key pressed 3 times | ||||
8 | Key held down and key released | ||||
15 (Default) |
All scenes sent | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
43 | 1 | Input 4 - sent scenes | 0 | No scenes sent | |
1 | Key pressed 1 time | ||||
2 | Key pressed 2 times | ||||
4 | Key pressed 3 times | ||||
8 | Key held down and key released | ||||
15 (Default) |
All scenes sent | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
62 | 2 | Power reports - periodic | 0 | periodic reports are disabled | |
30 to 32400 (Default) |
(30 - 32400 s) - report interval | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
63 | 2 | Analog inputs reports and output change on input change | 0 | reporting on change disabled | |
1 to 100 (Default) |
0.1 - 10 V, 0.1 V step | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
64 | 2 | Analog inputs reports - periodic | 0 (Default) |
periodical reports disabled | |
30 to 32400 | 30 - 32400 s, 1 s step | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
65 | 2 | Energy reports - on change | 0 | reports are disabled | |
1 to 500 (Default) |
(0.01 - 5 kWh) - change in energy | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 2 | Energy reports - periodic | 0 | periodic reports are disabled | |
30 to 32400 (Default) |
(30 - 32400 s) - report interval | ||||