TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | Alarm cancellation delay | 0 to 3600 (Default) |
Alarm cancellation delay | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 4 | High temperature alarm indicator colour | 0 to 16777215 (Default) |
High temperature alarm indicator colour | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Temperature indication using LED visual indicator | 0 to 2 (Default) |
Temperature indication using LED visual indicator | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Temperature measurement compensation | -10000 to 10000 (Default) |
Temperature measurement compensation | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Alarm frame sent to 1st and 4th Association Group activation (MOVEMENT_TAMPER / BUTTON_TAMPER) | 0 to 3 (Default) |
Alarm frame sent to 1st and 4th Association Group activation | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 4 | Alarms signalization duration | 0 to 65535 (Default) |
Alarms signalization duration | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 4 | Alarm signalization reactivation period | 0 to 65535 (Default) |
Alarm signalization reactivation period | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Flood sensor functionality turned off | 0 to 1 (Default) |
Flood sensor functionality turned off | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Associations in Z-Wave network security mode | 0 to 7 (Default) |
Associations in Z-Wave network security mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Acoustic and visual signals On / Off in case of flooding | 0 to 3 (Default) |
Acoustic and visual signals On / Off in case of flooding | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 2 | Requested dimming level / roller blind opening level when sending turn on / open command to 2nd association group devices | 1 to 255 (Default) |
Requested dimming level / roller blind opening level when sending turn on / open command to 2nd association group devices | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Deactivate turning off devices in 2nd association group & alarm cancellation in 3rd group | 0 to 1 (Default) |
Deactivate turning off devices in 2nd association group & alarm cancellation in 3rd group | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 4 | Temperature measurement interval | 1 to 65535 (Default) |
Temperature measurement interval | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Temperature measurement hysteresis | 1 to 1000 (Default) |
Temperature measurement hysteresis | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 2 | Low temperature alarm threshold | -10000 to 10000 (Default) |
Low temperature alarm threshold | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | High temperature alarm threshold | -10000 to 10000 (Default) |
High temperature alarm threshold | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 4 | Low temperature alarm indicator colour | 0 to 16777215 (Default) |
Low temperature alarm indicator colour | |