There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Temperature Unit | Use this parameter to switch from Fahrenheit to Celsius scale. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Celsius | ||||
1 | Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Temperature Reporting Threshold | Use it to set temperature change to be reported by the sensor. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
30 | 1 | 50 | No | No | No |
Value |
Description |
||||
1 | where 1 stands for 0.1 degree and 50 stands for 5 degrees | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Humidity Reporting Threshold | Use it to set humidity change to be reported by the sensor. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
20 | 1 | 50 | No | No | No |
Value |
Description |
||||
1 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Light Reporting Threshold | Use it to set brightness change to be reported by the sensor. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
25 | 5 | 50 | No | No | No |
Value |
Description |
||||
5 | where 5 stands for 5% and 50 stands for 50% | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Motion Clear Time | Use it to set trigger interval - the time when motion is reported again after initial trigger. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 1 | 127 | No | No | No |
Value |
Description |
||||
1 | minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Motion Sensitivity | Use it to adjust PIR sensor sensitivity. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
4 | 1 | 7 | No | No | No |
Value |
Description |
||||
1 | 1 = very high sensitivity and 7 = very low sensitivity | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | LED Mode | Use it to choose between LED indicator modes. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 3 | No | No | No |
Value |
Description |
||||
1 | LED indicator is turned off (no visual notifications). | ||||
2 | temperature and motion indicated with flashing light. Flashes every 3 minutes for temperature. | ||||
3 | no indication for temperature, motion indicated with red flashing light. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Retry Count | Set 0~10 Retry Count, default:3 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 0 | 10 | No | No | No |
Value |
Description |
||||
0 | retry count | ||||