TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | LED Indicator | 0 (Default) |
LED indicator is on when the plug is on, LED indicator is off when the plug is off | |
1 | LED indicator is on when the plug is off, LED indicator is off when the plug is on | ||||
2 | LED indicator is always off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 4 | Auto-off Timer Outlet 1 | 1 to 65535 | minutes | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 4 | Auto-off Timer Outlet 2 | 1 to 65535 | minutes | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 4 | Auto-on Timer Outlet 1 | 1 to 65535 | minutes | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 4 | Auto-on Timer Outlet 2 | 1 to 65535 | minutes | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | On/Off Status Recovery After Power Failure | 0 | both outlets on the plug automatically turn OFF once power is restored (it ignores the status prior to power outage) | |
1 | both outlets on the plug automatically turn ON once power is restored (it ignores the status prior to the power outage) | ||||
2 (Default) |
both outlets on the plug remember and restore the status prior to the power outage | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Brightness of LED indicator | 0 | High | |
1 | Medium | ||||
2 (Default) |
Low | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Z-Wave Button Control | 0 | Manual control disabled | |
1 (Default) |
Manual control enabled | ||||