There are over 4408 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Status LED Control | The configuration parameter 1 is a read/write parameter with a one-byte field, used to control the status LED. If set to on, the status LED will show the status of the latch every 6 seconds. If set to off, the status LED will not be shown. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Turns Status LED off | ||||
1 | Turns Status LED on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | Handing Control | The configuration parameter 10 is a read/write parameter with a one-byte field. When this parameter is read, it will return the handing of the lock. When this parameter is written, it will run a handing operation. When written with a value of 0x01, it will cause the lock to cycle through locking and unlocking until it determines the correct handing. It is suggested that this operation occur while the door is opened so that no obstructions will be in the way for the operation. After the completion of the handing process, a Configuration Report message will be sent back to the requestor. It will contain a non-zero value for success or a zero value for failure. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Unknown latch position (get/read from lock) | ||||
0 | Initiate the handing process (set/write to lock) | ||||
1 | Right handed lock (get/write to lock) | ||||
2 | Left handed lock (get/write to lock) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Sound Control | The configuration parameter 2 is a read/write parameter with a one-byte field, used to control the lock’s buzzer. If set to on, the buzzer is enabled and will sound during normal events. If set to off, the buzzer is disabled, and the buzzer sound will not occur. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Turns the sound (buzzer) off | ||||
1 | Turns the sound (buzzer) on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | User Program Button Control | The configuration parameter 3 is a read/write parameter with a one-byte field, used to control the user program button. If set to on, the program button is available for user code maintenance. If set to off, the program button is not available for user code maintenance. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Disables the program button | ||||
1 | Enables the program button | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Secure Screen Control | The configuration parameter 4 is a read/write parameter with a one-byte field, used to control the secure screen functionality on touch locks only. This parameter is not used on non-touch locks and will be ignored. If set to enabled, the touch screen will display the secure screen functionality when woken. If set to disabled, the touch screen will not display the secure screen functionality when woken. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Disables secure screen (Touch products only) | ||||
1 | Enables secure screen (Touch products only) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
40 | 1 | Factory Default Control | The configuration parameter 40 is a write only parameter with a one-byte field, used to request the lock to perform a factory reset back to its default state. This control will cause the lock to be removed from the network, placing the lock back to its default state. When a read is issued for this parameter, a 0 will be returned. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | No action (get) | ||||
1 | Perform a full factory reset (set) | ||||
2 | Perform a modified factory reset (set) - for production only | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
46 | 4 | Motor Load Value | The configuration parameter 46 is a read only parameter with a four-byte field. It is used to retrieve the calculated sideload value from the last motor run that was performed. This value is used to represent the amount of power needed to run the motor, giving the opportunity to see if any resistance was encountered based on the value read from a free running motor with no resistance. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 16777215 | Yes | No | No |
Value |
Description |
||||
0 | Provides an insight into the amount of resistance encountered by motor | ||||