There are over 4376 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Heavy Duty Smart Switch Gen5 (ZW078-A_Aeon_1406)

Z-Wave Certification Number: ZC10-14060004


Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 1 Set parameter 101~103 to default. 0 to 1
(Default)
When value==1, parameters 101 ~103 will be restored to default setting. When value==0, it will not restore any parameter.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 to set which report need to be sent. 0 to 15
(Default)
When value==1, which means the Voltage report is configured to be sent in Report Group 1. When value==2, which means the Current report is configured to be sent in Report Group 1. When value==4, which means the Wattage report is configured to be sent in Report Group 1. When value==8, which means the KWH report is configured to be sent in Report Group 1. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 1. The other values will be reserved.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 to set which report need to be sent. 0 to 15
(Default)
When value==1, which means the Voltage report is configured to be sent in Report Group 2. When value==2, which means the Current report is configured to be sent in Report Group 2. When value==4, which means the Wattage report is configured to be sent in Report Group 2. When value==8, which means the KWH report is configured to be sent in Report Group 2. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 2. The other values will be reserved.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 to set which report need to be sent. 0 to 15
(Default)
When value==1, which means the Voltage report is configured to be sent in Report Group 3. When value==2, which means the Current report is configured to be sent in Report Group 3. When value==4, which means the Wattage report is configured to be sent in Report Group 3. When value==8, which means the KWH report is configured to be sent in Report Group 2. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 3. The other values will be reserved.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 1 Set parameter 111~113 to default. 0 to 1
(Default)
When value==1, parameters 111 ~113 will be restored to default setting.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the interval time of sending report. 0 to 268435456
(Default)
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 Set the interval time of sending report. 0 to 268435456
(Default)
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 Set the interval time of sending report. 0 to 268435456
(Default)
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

200 1 Partner ID 0 to 255
(Default)
There are 255 different partners can be configured.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/Disable Lock Configuration 0 to 1
(Default)
When value==0, all configuration parameters are configurable. When value==1, all configuration parameters are not configurable.(Locked).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset to default factory setting 0 to 1431655765
(Default)
When value==1431655765, it will reset the product to default factory setting and be excluded from Z-wave network. When value==1, it only will reset the all configuration parameters to default setting. The other values will be reserved.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Current Overload Protection 0 to 1
(Default)
0=disabled, 1=enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 Enable/Disable to send notifications to associated devices to associated devices 0 to 2
(Default)
(0=nothing, 1=hail CC, 2=basic CC report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

90 1 Enable/Disable the function of parameter 91 and 92 0 to 1
(Default)
0=disabled, 1=enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

91 2 Induce an automatic report 0 to 60000
(Default)
The threshold can be set from 0 to 60000 watt.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

92 1 Induce an automatic report 0 to 100
(Default)
The threshold can be set from 0 to 100 percent.