There are over 4376 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
100 | 1 | Set parameter 101~103 to default. | 0 to 1 (Default) |
When value==1, parameters 101 ~103 will be restored to default setting. When value==0, it will not restore any parameter. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | to set which report need to be sent. | 0 to 15 (Default) |
When value==1, which means the Voltage report is configured to be sent in Report Group 1. When value==2, which means the Current report is configured to be sent in Report Group 1. When value==4, which means the Wattage report is configured to be sent in Report Group 1. When value==8, which means the KWH report is configured to be sent in Report Group 1. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 1. The other values will be reserved. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 4 | to set which report need to be sent. | 0 to 15 (Default) |
When value==1, which means the Voltage report is configured to be sent in Report Group 2. When value==2, which means the Current report is configured to be sent in Report Group 2. When value==4, which means the Wattage report is configured to be sent in Report Group 2. When value==8, which means the KWH report is configured to be sent in Report Group 2. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 2. The other values will be reserved. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 4 | to set which report need to be sent. | 0 to 15 (Default) |
When value==1, which means the Voltage report is configured to be sent in Report Group 3. When value==2, which means the Current report is configured to be sent in Report Group 3. When value==4, which means the Wattage report is configured to be sent in Report Group 3. When value==8, which means the KWH report is configured to be sent in Report Group 2. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 3. The other values will be reserved. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
110 | 1 | Set parameter 111~113 to default. | 0 to 1 (Default) |
When value==1, parameters 111 ~113 will be restored to default setting. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
112 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
113 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
200 | 1 | Partner ID | 0 to 255 (Default) |
There are 255 different partners can be configured. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
252 | 1 | Enable/Disable Lock Configuration | 0 to 1 (Default) |
When value==0, all configuration parameters are configurable. When value==1, all configuration parameters are not configurable.(Locked). | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset to default factory setting | 0 to 1431655765 (Default) |
When value==1431655765, it will reset the product to default factory setting and be excluded from Z-wave network. When value==1, it only will reset the all configuration parameters to default setting. The other values will be reserved. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Current Overload Protection | 0 to 1 (Default) |
0=disabled, 1=enabled | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
80 | 1 | Enable/Disable to send notifications to associated devices to associated devices | 0 to 2 (Default) |
(0=nothing, 1=hail CC, 2=basic CC report | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
90 | 1 | Enable/Disable the function of parameter 91 and 92 | 0 to 1 (Default) |
0=disabled, 1=enabled | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
91 | 2 | Induce an automatic report | 0 to 60000 (Default) |
The threshold can be set from 0 to 60000 watt. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
92 | 1 | Induce an automatic report | 0 to 100 (Default) |
The threshold can be set from 0 to 100 percent. | |