5 | Button Switch Function Disable | Setting this configuration as '0' will be disabling to turn on and off the relay by pressed button. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 0 | Button Switchwill be disabling to turn off | 1 | 1 | Button Switchwill be disabling to turn on |
|
7 | Channel 1 Off Time Setting | This configuration sets the time delay to turn off switch channel 1 when channel 1 is turned on. This configuration is only valid when “Configuration No.6” is set to '1'. Unit: minute. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 32767 | This configuration sets the time delay to turn off switch channel 1 when channel 1 is turned on. |
|
8 | Channel 2 Off Time Setting | This configuration sets the time delay to turn off switch channel 2 when channel 2 is turned on. This configuration is only valid when “Configuration No.6” is set to '1'. Unit: minute. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 32767 | This configuration sets the time delay to turn off switch channel 2 when channel 2 is turned on. |
|
6 | Timer Enable | Setting this configuration as '1' will start the timing function of the plug, and the length of time is determined by the setting of “Configuration: No.7”. This function can only provide the time to turn off device function when the device is open. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | turn off the timing function of the plug, | 1 | 1 | start the timing function of the plug, |
|
3 | Relay On/Off Indicate | This Parameter defines the relay state. The led will be turn on with pink color when the button is touched to turn on relay if this parameter is set to ‘1’; otherwise the led is off. The default value is ‘1’. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 0 | the led is off. | 1 | 1 | the led is on |
|
1 | Relay On/Off Status Saved Enable | This parameter defines the on/off status of relay is need to save or not. The status will be saved when relay status is changed if this parameter is set to ‘1’; otherwise the relay status is not saved. The wall switch will restore the relay On/Off status previous when power on again | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
1 | 1 | The relay status is saved each time it changes so that the relay will return to its previous state after a power failure. | 0 | 0 | The relay status is not saved when it changes, so it will not return to its previous state after a power failure. |
|
2 | Backlight Enable | This parameter defines the backlight state for touch button. The backlight led is on when wall switch power on if this parameter is set to ‘1’, otherwise the backlight led is off. The default value is ‘1’. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
1 | 1 | the backlight state for touch button. | 0 | 0 | the backlight led is off |
|
4 | Root Device Controlled Settings | This parameter defines which endpoint is mapped to root device (Endpoint 0). The valid values are explained as follows. The default value is ‘1’. 1 – Endpoint 1 is mapped to root endpoint 3 – Both endpoint 1 and 2 are mapped to root endpoint. For example, assumes this parameter is set to ‘1’ (default value). Controller or other devices (such as door/window sensor, motion sensor, etc) that associated the wall switch send a command BASIC_SET = 0xFF to wall switch, the relay in endpoint 1 will be turned on; other relay status will not be changed. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
1 | 1 | Endpoint 1 is mapped to root endpoint | 2 | 2 | Endpoint 2 is mapped to root endpoint | 3 | 3 | Both endpoint 1 and 2 are mapped to root endpoint. |
|