Product Recognition | |
|---|
Certification Number | ZC10-19066558 |
|---|
Name | Assure Lock SL Keyed Touchscreen |
|---|
Short Description | The Assure Lock SL features Z-Wave and seamlessly integrates into 50+ home automation and security systems including SmartThings, Alarm.com, Honeywell, ADT, Wink and more! When added to most Z-Wave automation systems, lock and unlock your door, create pin codes, view access history and receive notifications from anywhere. |
|---|
Long Description | Never worry about carrying around or losing your keys again. The Assure Lock SL features Z-Wave and seamlessly integrates into 50+ home automation and security systems including SmartThings, Alarm.com, Honeywell, ADT, Wink and more! When added to most Z-Wave automation systems, lock and unlock your door, create pin codes, view access history and receive notifications from anywhere. |
|---|
Brand | Yale Locks & Hardware |
|---|
Product Identifier | YRD228-ZW2 |
|---|
OEM Version | HW: 255 FW: 1.78:43.00 |
|---|
Hardware Platform | ZM5101 |
|---|
Z-Wave Version | 6.51.07 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Door Lock - Keypad |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_LISTENING |
|---|
Manufacturer ID | 0x0129 |
|---|
Product Type ID | 0x8002 |
|---|
Product ID | 0x0600 |
|---|
User Icon | 0x0300 |
|---|
Installer Icon | 0x0300 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
Categories | Locks |
|---|
Countries / Regions | United States of America |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Quantity | | Battery Type | | Door Lock Type | Value |
|---|
Deadbolt Motor Attachment |
| Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
| Outdoor Use | | Supported Notification Types | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 1 | 0 | Z-Wave Plus Lifeline |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
8 | Operating Mode | 00 = normal mode (this is the default mode) 01 = vacation mode, keypad lockout 02= privacy mode, no keypad. RF Unlock will work | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Normal Mode (Default) | 1 | 1 | Vacation Mode (Keypad Locked Out) | 2 | 2 | Privacy Mode (Keypad Locked, RF Unlock Functional) |
| 11 | One Touch Locking | 0x00 = OFF, 0xFF = ON default is 0xFF or ON. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
-128 | -128 | One Touch Locking On | 0 | 0 | One Touch Locking Off |
| 1 | Silent Mode on/off | Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent. Default is 2 or Low Volume | 0 | 1 | 0 | 0 | 1 | | 2 | Auto Relock On/Off | 0x00 = OFF, 0xFF = ON default is 0x00 or OFF | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
-128 | -128 | Auto Relock On | 0 | 0 | Auto Relock Off |
| 3 | Auto Relock Time | 10 to 180 seconds default is 30 seconds | 0 | 1 | 0 | 0 | 5 | From | To | Description |
|---|
10 | 180 | Seconds |
| 4 | Wrong Code Entry Limit | 3 to 10 default is 5 times | 0 | 1 | 0 | 0 | 5 | From | To | Description |
|---|
3 | 10 | Times |
| 5 | Language | 1=English, 2=Spanish, 3=French default is 1= English | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
1 | 3 | Language |
| 7 | Shut Down Time (after wrong code entries) | 10 to 180 seconds default is 60 seconds | 0 | 1 | 0 | 0 | 60 | From | To | Description |
|---|
10 | 180 | Seconds |
|
|
|---|
Texts | ID | Description | Value |
|---|
1 | Inclusion | 1. Enter the 4-8 digit master PIN code followed by the gear key.
2. Press the 7 key followed by the gear key.
3. Press the 1 key followed by the gear key. | 2 | Exclusion | 1. Enter the 4-8 digit master PIN code followed by the gear key.
2. Press the 7 key followed by the gear key.
3. Press the 3 key followed by the gear key. | 5 | Factory Reset | Please use this procedure only when the network primary controller is missing or otherwise inoperable.
1. Remove the inside lever with the lever removal tool.
2. Remove battery cover using hex wrench provided with lock.
3. Remove four (4) AA batteries.
4. Remove the 10-32 x 3/4"" pan head screw from the center of the battery housing into the barrel nut of the outside assembly.
5. Remove inside escutcheon. Cables may stay connected.
6. Reinstall batteries
7. On the back of the PC board, push and hold the Reset Button with the lever removal tool for 3 seconds.
8. While continuing the press the reset button, temporarily remove one AA battery.
9. Reinstall the battery
10. Release reset button and wait 15 seconds. Speaker will announce ""Welcome to Yale""
11. Reassemble escutcheon |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Access Control | (Refer to parameters): State idle |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Is Flirs | Yes |
|---|