Product Recognition | |
|---|
Certification Number | ZC10-19026383 |
|---|
Name | Connect+ Security Panel with Z-Wave Controller |
|---|
Short Description | The Connect+ Panels bring complete security and home automation into one platform, that is easy to install. Professional security that is UL compliant, modular, and customizable with snap-in modules for cellular backup, smart device control, and existing sensor take over. |
|---|
Long Description | Our Connect+ Panels bring complete security and home automation into one platform. A modern design that is easy to install and blends into any environment. Professional security that is UL compliant, with blazing fast communications and control. Modular and customizable with snap-in modules for cellular backup, smart device control, and existing sensor take over.
Your customers will love how easy it is to control their security with smart devices and easy setup of scenes and automation.
RE6100P-XX-X CONNECT+ PANEL
Ethernet Port
Backup Battery
UL Compliant
Snap-in Modules
Bluetooth Smart Radio Transceiver
Slot 1 & 2 Available Expansion Cards
LTE: RE929RPV
WI-FI: RE926RS
Slot 3 Pick 1 option
Z-WAVE: RE934Z
COMBINATION: RE934ZT |
|---|
Brand | Alula |
|---|
Product Identifier | RE6100 |
|---|
OEM Version | HW: 10 FW: 5.03:00.01 |
|---|
Hardware Platform | ZM5202 |
|---|
Z-Wave Version | 6.71.03 |
|---|
Library Type | CONTROLLER_STATIC |
|---|
Device Type | Central Controller |
|---|
Role Type | ROLE_TYPE_CONTROLLER_CENTRAL_STATIC |
|---|
Manufacturer ID | 0x0353 |
|---|
Product Type ID | 0x0001 |
|---|
Product ID | 0x0001 |
|---|
User Icon | 0x0100 |
|---|
Installer Icon | 0x0100 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
Categories | Security Systems |
|---|
Countries / Regions | United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_INCLUSION_CONTROLLER | Inclusion Controller | 0x74 | 1 | COMMAND_CLASS_CRC_16_ENCAP | CRC16 Encapsulation | 0x56 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC | Manufacturer Specific | 0x72 | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | Sensor Multilevel V5 | 0x31 | 5 | COMMAND_CLASS_SWITCH_BINARY_V2 | Switch Binary V2 | 0x25 | 2 | COMMAND_CLASS_NO_OPERATION | No Operation | 0x00 | 1 | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V4 | Thermostat Fan Mode V4 | 0x44 | 4 | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2 | Thermostat Operating State V2 | 0x42 | 2 | COMMAND_CLASS_INCLUSION_CONTROLLER | Inclusion Controller | 0x74 | 1 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi-Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_CLOCK | Clock | 0x81 | 1 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_TIME_PARAMETERS | Time Parameters | 0x8B | 1 | COMMAND_CLASS_BASIC | Basic | 0x20 | 1 | COMMAND_CLASS_CRC_16_ENCAP | CRC16 Encapsulation | 0x56 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Switch Multilevel V2 | 0x26 | 2 | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V2 | Thermostat Fan State V2 | 0x45 | 2 | COMMAND_CLASS_THERMOSTAT_MODE_V3 | Thermostat Mode V3 | 0x40 | 3 | COMMAND_CLASS_THERMOSTAT_SETPOINT_V3 | Thermostat Setpoint V3 | 0x43 | 3 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_BARRIER_OPERATOR | Barrier Operator | 0x66 | 1 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_MULTI_CHANNEL_V4 | Multi-Channel V4 | 0x60 | 4 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_DOOR_LOCK_V3 | Door Lock V3 | 0x62 | 3 | COMMAND_CLASS_MANUFACTURER_SPECIFIC | Manufacturer Specific | 0x72 | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED, S2_ACCESS_CONTROL |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Quantity | | Battery Type | | Color | | Firmware Updatable | Value |
|---|
Updatable by Manufacturer |
| Sensors | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 4 | 0 | Z-Wave Plus Lifeline, only Device Reset Locally Notification supported. |
|
|---|
Texts | ID | Description | Value |
|---|
6 | Additional Special Features | Security S2 enabled | 4 | Device Wake-Up | Even though there is a battery backup, the Z-Wave controller always remains in full power mode, Central Static Controller. | 1 | Inclusion | 1. Navigate to the Devices screen using the left side menu on the Touchpad.
2. Touch the “+ Add” icon on the top right corner to start adding Z-Wave.
3. Connect+ will start the addition process and the following messages will display on the right side of the screen. This may take only a few seconds, or up to a minute to complete if the Connect+ controller is busy.
4. When the second message above is displayed, Connect+ is now ready to add the new device. Follow the new device’s instructions to place it into inclusion mode. This is typically a button press.
5. After putting the device into inclusion mode, the following message will display on the screen. Depending on the device and number of supported command
classes, this may take only a few seconds or up to a minute to complete.
6. If inclusion is successful, Connect+ will begin a device interrogation and gather current device command class states. It may take several seconds to display current device status on the screen. By default, the device’s initial name is set to the assigned node number within the Z-Wave network. The following is an example of a typical light switch device. | 5 | Factory Reset | Two types of Z-Wave reset are supported: soft reset and hard reset. Soft reset will only reboot the Z-Wave controller and will retain all your devices. Use this if you are experiencing persistent network issues to attempt to correct them. A hard reset will set the Z-Wave controller in Connect+ back to its factory default and all network devices will be cleared.
1. Navigate to the Settings screen from the left side menu, or the Settings icon on the home screen on the Touchpad.
2. In the Settings menu, touch the last item “Panel” and enter your 4-digit security system PIN when prompted.
3. In the next sub-menu, scroll down and select the “Z-Wave” menu item.
4. Select either “Soft Reset” or “Hard Reset”. You will see a confirmation message on the screen before performing the reset action.
5. A hard reset typically takes 5-10 seconds to complete. A soft reset will take additional time to complete refreshing all devices on the network, approximately 30 seconds per enrolled device. On large networks this may take several minutes to complete before normal operation is expected to resume.
Please use this procedure only when the network primary controller is missing or otherwise inoperable. | 2 | Exclusion | 1.On the Z-Wave device page on the Touchpad, touch the “- Remove” icon in the top right corner.
2.Connect+ will start the removal process. Status messages will display on the right side of the screen, and follow similar steps to the Add process. You will be prompted to place the device into exclusion mode, which is typically a button press. Follow the device’s instructions to place it into exclusion mode.
3. If removal fails, try again until successful. | 3 | Learn Mode (adding another controller) | There are three “Learn Mode” commands available. First is Classic Learn Mode, used for both inclusion and exclusion to and from an existing network. This is an old style command used for direct line of site with a legacy controller that may not support the new learn modes. This mode is also used for controller replication, described in the Network Copy section of this manual.
The next two learn modes are Network Wide Inclusion Learn Mode (NWI), named just “Inclusion Mode” on the Touchpad, and Network Wide Exclusion Learn Mode (NWE), named “Exclusion Mode” on the Touchpad. These commands do not require direct line of site to the third party con-troller; however, it is recommended if possible.
1. Navigate to the Z-Wave sub-menu as described in the Factory Reset section of this manual.
2. If network requirements are met as explained above, then the “Join/Leave Another Z-Wave Net-work” option will be visible in the menu, otherwise it will not be present.
3. BEFORE selecting a Learn Mode from the sub menu, place the primary controller on the other network into Add or Remove mode.
4. From the sub menu, select the Learn Mode to join the other existing network. The learn mode is only active for roughly 10 seconds. If another primary network is found in that time frame, it will attempt a connection. The join process may take a few seconds to several minutes to complete.
5. After the Touchpad shows a successful learn mode completion, please wait at least 30-45 ADDITIONAL seconds to allow new network initialization and device discovery to complete. The above message will be displayed on the Touchpad as a reminder. |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|