2 | Set to start holding hands | This parameter can be used to set the motor open hand start function(Configuration Value set to 0) or closed(Configuration Value set to 1),The default value is 0 | 1 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 1 | 0: Enable motor open hand start function 1: Disable motor open hand start function |
|
1 | CONFIGURATION_SET | This parameter can be used to set the motor rotation direction,the motor direction is forward (Configuration Value set to 0) or the opposite direction(Configuration Value set to 1),The default value is 0 | 1 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 1 | 0: Forward 1: Opposite direction |
|
7 | Parameter 7 | Read the motor power supply type:This parameter can be used to read the motor power supply type,The power ofmotor is classified into:Mains power supply(Read into the Configuration Value is 0),battery power(Read into the Configuration Value is 1). | 1 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Read the motor power supply type |
|
3 | Parameter 3 | Configure weak electric switch mode:This parameter can be used to set the need of weak electric switch mode. Provide 4 kinds of weak electric switch mode is optional,respectively:Double-button reboundable switch(Configuration Value set to 1),Double-button not reboundable switch(Configuration Value set to 2),DC246 switch(Configuration Value set to 3),Single-button cyclic switch mode(Configuration Value set to 4),The default value is 1. | 1 | 1 | 1 | 4 | 1 | From | To | Description |
|---|
1 | 4 | weak electric switch mode selection |
|
8 | Parameter 8 | Manually set / cancel open borders:Manually set the open boundary of the curtain(Configuration Value set to 1), cancel manually open the border of the curtain(Configuration Value set to 0). | 1 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 1 | Manually set / cancel open borders |
|
4 | Parameter 4 | Configure strong electric switch mode:This parameter can be used to set the need of strong electric switch mode. Provide 3 kinds of weak electric switch mode is optional,respectively:Double-button not reboundable(Configuration Value set to 0) ,Hotel mode(Configuration Value set to 1),Double-button reboundable mode(Configuration Value set to 2),The default value is 0. | 1 | 1 | 0 | 2 | 0 | From | To | Description |
|---|
0 | 2 | Configure strong electric switch mode |
|
5 | Parameter 5 | Read whether the total limit is set:This parameter can be used to read the motor's total limit is already set.Not set the, limit(Read into the Configuration Value is 0);Already set the limit(Read into the Configuration Value is 1) | 1 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Read whether the total limit is set |
|
6 | Parameter 6 | Read the device type:This parameter can be used to read the type of the motor.Motor types are divided into curtain,motor(Read into the Configuration Value is 0x01),shutter(Read into the Configuration Value is 0x11),Venetian blinds (Read into the Configuration Value is 0x12) | 1 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Read the device type:This parameter can be used to read the type of the motor | 0 | 0 | Read the device type:This parameter can be used to read the type of the motor |
|
9 | Parameter 9 | Manually set / cancel close borders:Manually set the close boundary of the curtain(Configuration Value set to 1), cancel manually close the border of the curtain(Configuration Value set to 0). | 1 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 1 | anually set / cancel close borders |
|
10 | Parameter 10 | Delete the limit:This command can delete the limit that has been set for the motor. | 1 | 1 | 127 | 127 | 127 | From | To | Description |
|---|
127 | 127 | 0x7F: Delete the device limits |
|