| 9 | TurnAndGo | 0 = Turn&Go off, 1 = Turn&Go on. Used if the lock is using a optional rotation sensor. Latch&Go on will turn automatically when manual turn is detected. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | TurnAndGo off | | 1 | 1 | TurnAndGo on will turn automatically when manual turn is detected. |
|
| 5 | Auto Latch time | How many seconds from the lock has been unlatched to it automatically should close again. If 0 then it is disabled. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 60 | How many seconds from the lock has been unlatched to it automatically should close again. If 0 then it is disabled. |
|
| 4 | Turn degrees | Factor 10 turn degrees ( 1 = 10 degrees, 9 = 90 degrees etc.) | 0 | 1 | 0 | 0 | 9 | | From | To | Description |
|---|
| 1 | 100 | Factor 10 turn degrees ( 1 = 10 degrees, 9 = 90 degrees etc.) |
|
| 7 | Battery Type | Set the type of battery that powers the device. This affects the returned battery state. 0 = 3,6 Volt battery, 1 = 3.0 Volt battery. 2 = Mains power, changing from and to mains power requires the Danalock to be excluded and included. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 2 | 2 | Mains power, changing from and to mains power requires the Danalock to be excluded and included. | | 0 | 0 | 3,6 Volt battery | | 1 | 1 | 3.0 Volt battery. |
|
| 2 | Speed (Torque) | 1 = Slowest 2 = Slow 3 = Normal 4 = Fast 5 = Fastest | 0 | 1 | 0 | 0 | 3 | | From | To | Description |
|---|
| 1 | 1 | Slowest | | 2 | 2 | Slow | | 3 | 3 | Normal | | 4 | 4 | Fast | | 5 | 5 | Fastest |
|
| 11 | Async | 0 = Async off, 1 = Async on. Used if the lock is using an optional rotation sensor. When async is enabled the lock will auto calibrate if already unlatched and asked to Unlatch again (used for special door locks where the key turn is asynced from the inside nob.) | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | Async off | | 1 | 1 | Async on. Used if the lock is using an optional rotation sensor. When async is enabled the lock will auto calibrate if already unlatched and asked to Unlatch again (used for special door locks where the key turn is asynced from the inside nob.) |
|
| 1 | Direction | 0 = The motor goes clockwise when latched 1 = The motor goes counterclockwise when latched | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | The motor goes clockwise when latched | | 1 | 1 | The motor goes counterclockwise when latched |
|
| 8 | Battery alarm value | When the battery level is under this value, the device will notify user with a beep sound after latch or unlatch. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 100 | When the battery level is under this value, the device will notify user with a beep sound after latch or unlatch. |
|
| 6 | Sound | Disable or enable the beep sound from latch or unlatch operations(0 = Disable, 1 = Enable.) | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 1 | 1 | Enable the beep sound from latch or unlatch operations | | 0 | 0 | Disable the beep sound from latch or unlatch operations |
|
| 3 | Mode | 0 = Stepper motor mode wave drive(power saving) 1 = Stepper motor mode full drive(Normal) 2 = Relay mode | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | Stepper motor mode wave drive(power saving) | | 1 | 1 | Stepper motor mode full drive(Normal) | | 2 | 2 | Relay mode |
|