41 | OVERLOAD alarm report (load power consumption too high) | 0 - No reaction
1 - Send an alarm frame | 1 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 1 | OVERLOAD alarm report |
|
42 | LOAD ERROR alarm report (no load, load failure, burnt out bulb) | 0 - No reaction
1 - Send an alarm frame | 1 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 1 | LOAD ERROR alarm report |
|
1 | Minimum brightness level | This parameter is set automatically during the calibration process. The parameter can be changed manually after
the calibration. The maximum brightness level (parameter 2) must be greater than the minimum brightness level
(parameter 1). | 1 | 1 | 1 | 98 | 1 | From | To | Description |
|---|
1 | 98 | percentage level of brightness |
|
2 | Maximum brightness level | This parameter is set automatically during the calibration process. The parameter can be changed manually after
the calibration. The maximum brightness level (parameter 2) must be greater than the minimum brightness level
(parameter 1). | 1 | 1 | 2 | 99 | 99 | From | To | Description |
|---|
2 | 99 | percentage level of brightness |
|
3 | . Incandescence level of dimmable compact fluorescent lamps | Virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The Dimmer-Control will
set to this value after first switch on. It is required for warming up and switching dimmable compact fluorescent
lamps and certain types of light sources. | 1 | 1 | 1 | 99 | 1 | From | To | Description |
|---|
1 | 99 | percentage level of brightness |
|
9 | State of the device after a power failure | The Dimmer-Control will return to the last state before power failure. | 1 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 1 | state before power failure. |
|
5 | Automatic control - dimming step size | This parameter defines the percentage value of dimming step during the automatic control. Automatic control is
performed through:
- single push-button click
- double push-button click
- Z-Wave control frames | 1 | 1 | 1 | 99 | 0 | From | To | Description |
|---|
1 | 99 | dimming step percentage value |
|
10 | Timer functionality (auto - off) | This parameter allows to automatically switch off the device after specified time from switching on the light
source. It may be useful when Dimmer-Control is installed in the stairway | 1 | 2 | 0 | 32767 | 0 | From | To | Description |
|---|
0 | 32767 | Timer functionality (auto - off) |
|
4 | Incandescence time of dimmable compact fluorescent lamps | This parameter determines the time required for switching compact fluorescent lamps and certain types of light
sources. Setting this parameter to 0 will disable the incandescence functionality | 1 | 2 | 1 | 25 | 0 | From | To | Description |
|---|
1 | 25 | time of dimmable compact fluorescent lamps |
|
8 | Manual control - time of a dimming step | This parameter defines the time of single dimming step set in parameter 7 during the manual control. | 1 | 2 | 0 | 255 | 5 | From | To | Description |
|---|
0 | 255 | time of a dimming step |
|
7 | Manual control - dimming step size | This parameter defines the percentage value of dimming step during the manual control. Manual control is performed through holding the push-button | 1 | 1 | 1 | 99 | 1 | From | To | Description |
|---|
1 | 99 | dimming step percentage value |
|
6 | Automatic control - time of a dimming step | This parameter defines the time of single dimming step set in parameter 5 during the automatic control. | 1 | 2 | 0 | 255 | 1 | From | To | Description |
|---|
0 | 255 | time of a dimming step |
|
11 | ALL ON/ALL OFF function | Parameter allows for activation/deactivation of Z-Wave commands enabling/disabling all devices located in direct
range of the main controller | 1 | 2 | 0 | 255 | 255 | From | To | Description |
|---|
0 | 255 | ALL ON/ALL OFF function | 0 | 255 | ALL ON/ALL OFF function |
|
17 | Switch type | Choose between momentary, toggle and roller blind switch. | 1 | 1 | 0 | 2 | 0 | From | To | Description |
|---|
0 | 2 | Choose between momentary |
|
23 | The function of 3-way switch | Switch no. 2 controls Dimmer-Control additionally (in 3-way switch mode). Function disabled for parameter 20 set
to 2 (roller blind switch). | 1 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 1 | The function of 3-way switch |
|
25 | Scene activation functionality | SCENE ID depends on the switch type configurations (see Table A5). Enabling scene activation functionality may
cause slight delay in response to external switches and sending associations. | 1 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 1 | Scene activation functionality |
|
31 | Soft-Start functionality | Time required to warm up the filament of halogen bulb. | 1 | 1 | 0 | 2 | 1 | From | To | Description |
|---|
0 | 2 | Soft-Start functionality |
|
43 | OVERCURRENT alarm report (short circuit, burnt out bulb causing overcurrent) | 0 - No reaction
1 - Send an alarm frame | 1 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 1 | OVERCURRENT alarm report |
|
44 | SURGE alarm report (Dimmer-Control output overvoltage) | 0 - No reaction
1 - Send an alarm frame | 1 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 1 | SURGE alarm report |
|
45 | OVERHEAT (critical temperature) and VOLTAGE DROP (low voltage) alarm report | 0 - No reaction
1 - Send an alarm frame | 1 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 1 | OVERHEAT (critical temperature) and VOLTAGE DROP |
|
46 | Active power reports | The parameter defines the power level change that will result in a new power report being sent. The value is a
percentage of the previous report. | 1 | 1 | 0 | 100 | 10 | From | To | Description |
|---|
0 | 100 | Active power reports |
|
47 | Periodic active power and energy reports | Parameter 52 defines a time period between consecutive reports. Timer is reset and counted from zero after each
report | 1 | 2 | 0 | 32767 | 3600 | From | To | Description |
|---|
0 | 32767 | Periodic active power and energy reports |
|
48 | Energy reports | Energy level change which will result in sending a new energy report. | 1 | 2 | 0 | 255 | 10 | From | To | Description |
|---|
0 | 255 | Energy reports |
|
49 | Self-measurement | The Dimmer-Control may include active power and energy consumed by itself in reports sent to the main controller. | 1 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 1 | Self-measurement |
|
50 | Method of calculating the active power | This parameter defines how to calculate active power. It is useful in a case of 2-wire connection with light sources
other than resistive. Parameter 58 is set to 0 after forced auto-calibration. | 1 | 1 | 0 | 2 | 0 | From | To | Description |
|---|
0 | 2 | Method of calculating the active power |
|
51 | Approximated power at the maximum brightness level | This parameter determines the approximate value of the power that will be reported by the device at its maximum
brightness level. Parameter 59 works only when parameter 58 has a value other than 0. | 1 | 2 | 0 | 500 | 0 | From | To | Description |
|---|
0 | 500 | Approximated power at the maximum brightness level |
|