Product Recognition | |
|---|
Certification Number | ZC10-15090019 |
|---|
Name | Door/window sensor |
|---|
Short Description | ZC-100 surface mount sensor is a battery-powered Z-Wave magnetic door/window contact sensor which is used to indicated the door/window on-off status. |
|---|
Long Description | Sentek’s ZC-100 surface mount sensor is a battery-powered Z-Wave magnetic door/window contact sensor for surface mounting. ZC-100 sends radio signals when the Switch and actuate-magnet separate. By taking
advantage of Z-Wave mesh network, commands can be routed to their destination via intermediary “listening” Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices.
The Sentek Door / Window Sensor is designed for use with scenes in home automation systems, alarm and surveillance systems and everywhere else where information related to opening / closing of doors, windows, garage gates, etc. is needed. Suitable for smart home systems. |
|---|
Brand | Sentek |
|---|
Product Identifier | ZC-100 |
|---|
OEM Version | 01 |
|---|
Hardware Platform | ZM5202 |
|---|
Z-Wave Version | 6.51.06 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x0185 |
|---|
Product Type ID | 0x0003 |
|---|
Product ID | 0x0008 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | European Union |
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC | Basic | 0x20 | 1 |
|
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 4 | 0 | Z-Wave Plus Lifeline
Group I is assigned to input IN1, TMP button and the
magnetic sensor, Sending BASIC SET or ALARM command frames. | 2 | 4 | 0 | Group II is assigned to the magnetic sensor, Sending
BASIC SET frames | 3 | 4 | 0 | Group III is assigned to input IN1, TMP button, Sending
ALARM command frames | 4 | 4 | 0 | Group IV is assigned to input IN1, TMP button, Sending
ALARM command frames |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
1 | LED Controll | Available parameter settings: 0 - LED disable, 1 - LED enable | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 1 | LED controll | 0 | 0 | |
| 4 | Type of IN input | Available parameter settings: 0 – INPUT_NO (Normal Open) 1 – INPUT_NC (Normal Close) | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 1 | Type of IN input | 0 | 0 | |
| 5 | Type of control frame transmitted, activated via IN input. | The parameter allows you to specify the type of an alarm frame or to force control frames transmission (BASIC_SET) Default value: 255 – BASIC SET Available parameter settings: 1 – ALARM SMOKE frame 2 – ALARM CO frame 3 – ALARM CO2 frame 4 – ALARM OVERHEAT frame 5 – ALARM WATER frame 255 – Control frame BASIC_SET | 0 | 1 | 0 | 0 | 255 | From | To | Description |
|---|
1 | 5 | the type of an alarm frame | 255 | 255 | force control frames transmission (BASIC_SET) |
|
|
|---|
Texts | ID | Description | Value |
|---|
1 | Inclusion | 1.Install the device for correct positioning of
the Sensor and the magnet according to the manual.
2.Set the Z-Wave controller to the inclusion mode.
3.The ZC-100 Door/Window Sensor is added to the network by quickly
pressing the TMP button three times .
4. Correct inclusion of the device to the network will be signalled by
the Z-Wave controller. | 5 | Factory Reset | Note: Use the reset procedure only in the event that the network primary controller is missing or otherwise inoperable.
1. Pressed the TMP button more than 5 seconds.
2. Release the TMP button while the device's Led start blinking.
3. Reset is performed. | 4 | Device Wake-Up | Any action of TMP button and the magnetic sensor will wakeup the product. And by default every 5 minutes the product will wakeup. | 2 | Exclusion | 1.Install the device for correct positioning of
the Sensor and the magnet according to the manual.
2.Set the Z-Wave controller to the exclusion mode.
3.The ZC-100 Door/Window Sensor is delete from the network by quickly
pressing the TMP button three times.
4. Correct exclusion of the device from the network will be signalled by
the Z-Wave controller. |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|