| Product Recognition | |
|---|
| Certification Number | ZC14-25120565 |
|---|
| Name | Door/Window Sensor 8 |
|---|
| Short Description | Aeotec Z-Wave Door/ Window Sensor 8 |
|---|
| Description | Aeotec Door Window Sensor 8 is a sensor designed to detect whether a window/ or door is open, closed, or tilted. This sensor is easy to install. Thanks to its slim design, the Door Window Sensor 8 can be discreetly installed on any window. Simply mount the sensor on the window frame and place a slim magnet on the frame near the sensor. Additionally, the sensor integrates temperature and humidity sensors, allowing it to reliably monitor the status of the window/ door while also detecting indoor environmental conditions. Twice clicking the action button includes (adds) or excludes (removes) the device. A single press wakes up the device.
This product supports Security 2 Command Class. While a Security S2 enabled Controller is needed in order to fully use the security feature. This product can be operated in any Z-Wave® network with other Z-Wave/ Z-Wave Plus® certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. This product also supports SmartStart. |
|---|
| Brand | Aeotec |
|---|
| Brand Owner | Aeotec Limited |
|---|
| Identifier | ZWA055-C |
|---|
| Product Line | Z-Wave Product Line |
|---|
| Product URL | www.aeotec.com |
|---|
| OEM Version | HW: 55 FW: 01.00 |
|---|
| Hardware Platform | EFR32ZG23A |
|---|
| Z-Wave Version | 7.23.2 |
|---|
| Library Type | END_NODE_ENHANCED_232 |
|---|
| Device Type | Notification Sensor DT |
|---|
| Role Type | ROLE_TYPE_END_NODE_ALWAYS_ON, ROLE_TYPE_END_NODE_SLEEPING_REPORTING |
|---|
| Manufacturer ID | 0x0371 |
|---|
| Product Type ID | 0x0002 |
|---|
| Product ID | 0x0037 |
|---|
| User Icon | 0x0C06 |
|---|
| Installer Icon | 0x0C06 |
|---|
| Radio Range Z-Wave (m) | 40 |
|---|
| Radio Range Z-Wave LR (m) | 400 |
|---|
| Frequency Plans | EU: 869.85MHz, 868.40MHz, EU_LR: 864.00MHz, 866.00MHz |
|---|
| Categories | Sensors |
|---|
| Countries / Regions | Armenia, Bahrain, European Union, Cyprus, Moldova, Egypt, French Guiana, Georgia, Iraq, Jordan, Kazakhstan, Kuwait, Lebanon, Libya, Maldives, Mauritius, Nigeria, Oman, Philippines, Qatar, Saudi Arabia, South Africa, Turkmenistan, United Arab Emirates, ZU, Yemen |
|---|
| Supported Command Classes | | Identifier | Name | Key | Version |
|---|
| COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | | COMMAND_CLASS_SENSOR_BINARY_V2 | Binary Sensor V2 | 0x30 | 2 | | COMMAND_CLASS_SENSOR_MULTILEVEL_V11 | Multilevel Sensor V11 | 0x31 | 11 |
|
|---|
| S2 Classes | S2_AUTHENTICATED, S2_UNAUTHENTICATED |
|---|
| Documents | |
|---|
| Features | | Feature | Values |
|---|
| Battery Quantity | | | Battery Type | | | Color | | | Firmware Updatable | | Value |
|---|
| Updatable by Consumer by RF |
|
|
|---|
| Association Groups | | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
| 1 | 5 | 0 | Lifeline | 0x0001 | | 2 | 5 | 0 | Control | 0x7106 | | 3 | 5 | 0 | Alarm | 0x7106 | | 4 | 5 | 0 | Tamper | 0x7107 | | 5 | 5 | 0 | Tilting | 0x7106 | | 6 | 5 | 0 | Temperature High Trigger | 0x7104 | | 7 | 5 | 0 | Temperature Low Trigger | 0x7104 | | 8 | 5 | 0 | Humidity High Trigger | 0x7110 | | 9 | 5 | 0 | Humidity Low Trigger | 0x7110 | | 10 | 5 | 0 | Mold danger | 0x7110 | | 11 | 5 | 0 | Air Temperature | 0x7104 |
|
|---|
| Configuration Parameters | | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
|---|
| 1 | Set threshold Check Time | Set threshold Check Time | 1 | 4 | 0 | 0 | 0x00000384 | | 2 | Minimum temperature change to report | Trigger temperature report | 1 | 1 | 0 | 0 | 0x14 | | 3 | Minimum humidity change to report | Trigger humidity report | 1 | 1 | 0 | 0 | 0x32 | | 4 | Enable led indication | Enable led indication | 3 | 1 | 0 | 0 | 0x3F | | 5 | State when the magnet is closed | State when the magnet is closed | 2 | 1 | 0 | 0 | 0x00 | | 6 | Group 2 trigger | Set magnet status that causes sending | 2 | 1 | 0 | 0 | 0x00 | | 7 | Command sent to Group 2 | Set which command to send | 2 | 1 | 0 | 0 | 0x02 | | 8 | Basic On of Group 2 | Value of basic set on | 1 | 1 | 0 | 0 | 0xFF | | 9 | Basic Off of Group 2 | Value of basic set off | 1 | 1 | 0 | 0 | 0x00 | | 10 | Time delay of ON command | On command is sent after a delay | 1 | 2 | 0 | 0 | 0x0000 | | 11 | Time delay of OFF command | Off command is sent after a delay | 1 | 2 | 0 | 0 | 0x0000 | | 17 | Humidity Lower Watermark value | Send BASIC Set to Group 9 if below | 1 | 2 | 0 | 0 | 0x012C | | 23 | Low battery threshold | Low battery threshold | 1 | 1 | 0 | 0 | 0x14 | | 24 | Periodic Reports | Periodic Reports | 1 | 4 | 0 | 0 | 0x0000A8C0 | | 25 | Offset value for Temperature | Calibrate temperature | 0 | 2 | 0 | 0 | 0x0000 | | 31 | Basic On of Group 5 | Value of basic set on | 1 | 1 | 0 | 0 | 0xFF | | 64 | Temperature & Dew Point Scale | scale for auto reports and setting | 2 | 1 | 0 | 0 | 0x00 |
|
|---|
| Texts | | ID | Description | Value |
|---|
| 8 | Where to find S2 DSK on product | Page 4-5 in the Engineering Spec Manual | | 1 | Classic Inclusion | 1. Turn your main Controller into adding mode.
2. Click the Action Button 2 times. | | 2 | Classic Exclusion | 1. Turn your main Controller into removing mode.
2. Click the Action Button 2 times. | | 4 | Wake-Up Procedure | Click the Action Button once. | | 5 | Factory Reset Procedure | Press and hold the Action Button for 12s. |
|
|---|
| Supported Notification Types | | Notification Type | Event / State |
|---|
| Heat Alarm | (Refer to parameters): State idle | | Heat Alarm | Heat sensor status: Overheat detected | | Heat Alarm | Heat sensor status: Under heat detected | | Access Control | (Refer to parameters): State idle | | Access Control | Door state: Window/door is open | | Access Control | Door state: Window/door is closed | | Home Security | (Refer to parameters): State idle | | Home Security | Cover status: Tampering, product cover removed | | Power Management | (Refer to parameters): State idle | | Power Management | Power status: Power has been applied | | Power Management | Mains status: AC mains disconnected | | Power Management | Mains status: AC mains re-connected | | Power Management | Battery maintenance status: Replace battery now | | Weather Alarm | (Refer to parameters): State idle | | Weather Alarm | Moisture alarm status: Moisture alarm |
|
|---|
| Supported Multilevel Sensors | | Multilevel Sensor Type |
|---|
| Air temperature | | Humidity | | Dew point | | Acceleration X-axis | | Acceleration Y-axis | | Acceleration Z-axis |
|
|---|
| Supports NWI | Yes |
|---|
| Supports Explorer Frames | Yes |
|---|
| Supports SmartStart | Yes |
|---|