Product Recognition | |
|---|
Certification Number | ZC10-19116790 |
|---|
Name | Eugenio |
|---|
Short Description | Eugenio is Evolvere IoT hub which connects multi-brand smart devices to Evolvere Cloud, for easy management of the smart home |
|---|
Long Description | Eugenio is an home gateway manager (HGM) with an innovative design that interacts with ZWave devices. It can be controlled and configured by means of a smartphone APP, which permits to create scenarios and automation rules and to monitor the conditions of your home.
The wireless technology which empowers Eugenio and smart devices permits to make the home smarter, easily and quickly. No more cables! Anytime Eugenio let you add new multi-brand sensors or actuators to enhance the possibilities of home control, achive energy savings and guarantee your family safety.
Eugenio allows you to remotely control the status of the devices, create moments with customized rules for every daily needs, receive notifications of alarms and anomalies. Eugenio is compatible with lots of sensors and the number of these sensors is constantly growing.
The main application areas are:
o Energy management: smart metering to control by App consumption, energy production from photovoltaic systems and electricity grid exchanges; management of electrical loads to reduce energy waste; energy check-up service to help you save energy.
o Smart Thermostat: Evolvere's digital and connected thermostat let you manage home heating in a very simple way, even remotely. Through Eugenio’s App you can achive thermal comfort and energy saving, reducing your bills and your environmental impact
o Safety: motion sensors and door openings, smoke sensors, flood sensor, etc.
o Comfort and Quality: air quality control and management, lighting management |
|---|
Brand | Evolvere |
|---|
Product Identifier | Sentinel 2.0 |
|---|
OEM Version | HW: 1 FW: 6.04:02.81:01.00:01.00 |
|---|
Hardware Platform | ZM5304 |
|---|
Z-Wave Version | 6.81.04 |
|---|
Library Type | CONTROLLER_BRIDGE |
|---|
Device Type | Gateway |
|---|
Role Type | ROLE_TYPE_CONTROLLER_CENTRAL_STATIC |
|---|
Manufacturer ID | 0x036F |
|---|
Product Type ID | 0x0001 |
|---|
Product ID | 0x0001 |
|---|
User Icon | 0x0500 |
|---|
Installer Icon | 0x0500 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | All Controllers, Gateway Controller |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_NODE_PROVISIONING | Node Provisioning | 0x78 | 1 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_NETWORK_MANAGEMENT_INSTALLATION_MAINTENANCE | Network Management Installation and Maintenance | 0x67 | 1 | COMMAND_CLASS_INCLUSION_CONTROLLER | Inclusion Controller | 0x74 | 1 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_CRC_16_ENCAP | CRC16 Encapsulation | 0x56 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta-Data V5 | 0x7A | 5 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information V3 | 0x59 | 3 | COMMAND_CLASS_NETWORK_MANAGEMENT_INCLUSION_VERSION_3 | Network Management Inclusion V3 | 0x34 | 0 | COMMAND_CLASS_NETWORK_MANAGEMENT_PROXY_V2 | Network Management Proxy V2 | 0x52 | 2 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_NETWORK_MANAGEMENT_BASIC_V2 | Network Management Basic V2 | 0x4D | 2 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CMD | Multi-Command | 0x8F | 1 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_SWITCH_BINARY_V2 | Switch Binary V2 | 0x25 | 2 | COMMAND_CLASS_ALARM_V2 | Alarm V2 | 0x71 | 2 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi-Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_SENSOR_BINARY_V2 | Sensor Binary V2 | 0x30 | 2 | COMMAND_CLASS_THERMOSTAT_SETPOINT_V3 | Thermostat Setpoint V3 | 0x43 | 3 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_SENSOR_MULTILEVEL_V10 | Sensor Multilevel V10 | 0x31 | 10 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta-Data V5 | 0x7A | 5 | COMMAND_CLASS_MULTI_CHANNEL_V4 | Multi-Channel V4 | 0x60 | 4 | COMMAND_CLASS_SWITCH_MULTILEVEL_V4 | Switch Multilevel V4 | 0x26 | 4 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_CONFIGURATION_V3 | Configuration V3 | 0x70 | 3 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_SWITCH_COLOR | Switch Color | 0x33 | 1 | COMMAND_CLASS_METER_V4 | Meter V4 | 0x32 | 4 | COMMAND_CLASS_MULTI_CMD | Multi-Command | 0x8F | 1 | COMMAND_CLASS_APPLICATION_CAPABILITY | Application Capability | 0x57 | 1 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED, S2_ACCESS_CONTROL |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Type | | Battery Quantity | | Firmware Updatable | Value |
|---|
Updatable by Consumer via Internet |
| Sensors | Value |
|---|
Luminance | Humidity | Smoke Density | Voltage | Current | Seismic Intensity | Loudness | Volatile Organic Compound | Particulate Matter | Carbon Dioxide | Carbon Monoxide |
| Supported Meter Type | | Supported Notification Types | Value |
|---|
Smoke Alarm | CO2 Alarm | Water Alarm |
| Communications Connections | Value |
|---|
Ethernet (Wireless/WiFi) |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 5 | 0 | Z-Wave Plus Lifeline |
|
|---|
Texts | ID | Description | Value |
|---|
5 | Factory Reset Procedure | If this controller is the primary controller for your network, the factory reset operation will result in the nodes in your network being orphaned and it will be necessary after the execution of reset operation to exclude and re-include all of the nodes in the network. If this controller is being used as a secondary controller in the network, use this procedure to reset this controller only in the event that the network primary controller is missing or otherwise inoperable.
To reset the controller, hold the reset button for 16 seconds. This will reset it to factory default. | 3 | Learn Mode (adding another controller) Procedure | To include the controller into an existing Z-Wave network, use the UI and follow the steps below.
Click on Z-Wave tab and select Learn mode from a primary controller. This will shift the controller to have a secondary controller role and will receive data from the primary controller in the network. | 23 | Controller Inclusion | To include a Z-Wave device into the Z-Wave network using Eugenio Controller, use the inclusion wizard available on the mobile app and follow the on-screen instructions.
During this process you do not need to use the buttons on the Controller. | 24 | Controller Exclusion | To exclude a Z-Wave device from the Z-Wave network using Eugenio Controller, use the exclusion wizard available on the mobile app and follow the on-screen instructions.
Refer to device documentation for detailed instructions |
|
|---|
Supported / Controlled Meter Types | Meter Type | Rate Type | Description |
|---|
Electric meter | Import | Electric Meter Consumption |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|