4 | Parameter no. 4 – Input 1 contact type | This parameter determines how the switch or push-button is connected. Values (size is 1 byte dec): • default value 0 • 0 - NO (normally open) input type • 1 - NC (normally close) input type | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | NO (normally open) input type | 1 | 0 | NC (normally close) input type |
|
1 | Parameter no. 1 – Input I1 switch type | With this parameter, you can select between push-button (momentary) and on/off toggle switch types. Values (size is 1 byte dec): • default value 1 • 0 - push-button (momentary) • 1 - on/off toggle switch | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 0 | push-button (momentary) | 1 | 0 | on/off toggle switch |
|
59 | Parameter no. 59 - Thermostat mode | This parameter determines how the device will operate if it will operate in the heating mode or in the cooling mode. The range of the hysteresis will remain the same, only operation will change from heating to cooling and vice versa Values (size is 1 byte dec): • default value 0 • 0 - Heat mode • 1 - Cool mode NOTE1: After parameter change, first exclude device (without setting parameters to default value) and then re include the device! | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
1 | 0 | Cool mode | 0 | 0 | Heat mode |
|
60 | Parameter no. 60 – Too low temperature limit | This parameter determines the temperature at which the device sends a command to the associated device - to turn ON device or to turn OFF device: Values (size is 2 byte dec): • Default value 50 (Too low temperature limit is 5.0 °C) • -150 - 2120 NOTE1: Too low temperature limit is used with Association Group 3. NOTE2: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is -150 – 1000 (-15.0 °C – 100.0 °C, resolution 0.1 °C) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 50 – 2120 (5.0 °F – 212.0 °F, resolution 0.1 °F) NOTE4: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. | 0 | 2 | 0 | 0 | 50 | From | To | Description |
|---|
0 | 0 | Default value 50 (Too low temperature limit is 5.0 Celsius) | -150 | 2120 | This parameter determines the temperature at which the device sends a command to the associated device - to turn ON device or to turn OFF device. NOTE1: Too low temperature limit is used with Association Group 3. NOTE2: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is -150 – 1000 (-15.0 °C – 100.0 °C, resolution 0.1 °C) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 50 – 2120 (5.0 °F – 212.0 °F, resolution 0.1 °F) NOTE4: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. |
|
43 | Parameter no. 43 – Hysteresis Upper temperature offset | This parameter defines minimum temperature difference between real measured temperature and set-point temperature to turn device on in heat mode or turn device off in cool mode. Values (size is 2 byte dec): • default value 5 (0.5 °C) • 0 – 450 NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 0 – 250 (0.0 °C – 25.0 °C, resolution 0.1 °C) NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 0 – 450 (0.0 °F – 45.0 °F, resolution 0.1 °F) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. | 0 | 2 | 0 | 450 | 5 | From | To | Description |
|---|
0 | 450 | This parameter defines minimum temperature difference between real measured temperature and set-point temperature to turn device on in heat mode or turn device off in cool mode. NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 0 – 250 (0.0 °C – 25.0 °C, resolution 0.1 °C) NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 0 – 450 (0.0 °F – 45.0 °F, resolution 0.1 °F) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. |
|
78 | Parameter no. 78 – Scale Selection | This parameter determines in which measurement unit the device will report temperature (Fahrenheit or Celsius) and determines the scale the configuration parameters (43, 44, 44, 45, 60, 61, 110, 120) are interpreted as. Values (size is 1 byte dec): • Default value 0 = degrees Celsius • 0 = degrees Celsius • 1 = degrees Fahrenheit NOTE1: This scale has influence on Temperature reporting. The device is capable of receiving a Set point in all supported scales. NOTE2: This configuration parameter has impact on configuration parameters 43, 44, 44, 45, 60, 61, 110, 120. If scale is set to degrees Fahrenheit configuration values at parameters 43, 44, 44, 45, 60, 61, 110, 120 will be converted to degrees Celsius. Please note that converted values could drift when converting values back and forth. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
1 | 0 | 1 = degrees Fahrenheit | 0 | 0 | 0 = degrees Celsius |
|
110 | Parameter no. 110 – Temperature Sensor Offset Settings | Set value is added to or subtracted from the actually measured value to adjust the temperature report sent by an external sensor. Values (size is 2 byte dec): • default value 0 • -270 - 270 NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is -150 – 150 (-15.0 °C – 15.0 °C, resolution 0.1 °C) NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is -270 - 270 (-27.0 °F – 27.0 °F, resolution 0.1 °F) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | default value 0 | -270 | 270 | Set value is added to or subtracted from the actually measured value to adjust the temperature report sent by an external sensor. NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is -150 – 150 (-15.0 °C – 15.0 °C, resolution 0.1 °C) NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is -270 - 270 (-27.0 °F – 27.0 °F, resolution 0.1 °F) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. |
|
120 | Parameter no. 120 – Temperature Sensor Reporting Threshold | This configuration parameters sets reporting threshold between reported temperature and actual temperature for reporting temperature at association group 4. Values (size is 2 byte dec): • Default value 5 = 0.5°C • 0 – Reporting disabled • 0 - 270 NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 0 – 150 (0 °C – 15.0 °C, resolution 0.1 °C) NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 0 - 270 (0 °F – 27.0 °F, resolution 0.1 °F) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. | 0 | 2 | 0 | 0 | 5 | From | To | Description |
|---|
0 | 0 | Reporting disabled | 0 | 270 | This configuration parameters sets reporting threshold between reported temperature and actual temperature for reporting temperature at association group 4. NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 0 – 150 (0 °C – 15.0 °C, resolution 0.1 °C) NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 0 - 270 (0 °F – 27.0 °F, resolution 0.1 °F) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. |
|
63 | Parameter no. 63 – Output switch selection | Set value determines the type of the device connected to the on/off output. The output type can be normally open (NO) or normally closed (NC). Values (size is 1 byte dec): • default value 0 • 0 - When switch/device is off the output is 0V (NC). • 1 - When switch/device is off the output is 240V or 24V (NO). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | When switch/device is off the output is 0V (NC) | 1 | 0 | When switch/device is off the output is 240V or 24V (NO). |
|
61 | Parameter no. 61 – Too high temperature limit | This parameter determines the temperature at which the device sends a command to the associated device, to turn ON device or to turn OFF device. Values (size is 2 byte dec): • default value 700 (too high temperature limit is 70.0 °C) • 1 - 2120 NOTE1: Too high temperature limit is used with Association Group 3. NOTE2: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 1 – 1000 (0.1 °C – 100.0 °C, resolution 0.1 °C) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 322 – 2120 (32.2 °F – 212.0 °F, resolution 0.1 °F) NOTE4: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. | 0 | 2 | 0 | 0 | 700 | From | To | Description |
|---|
0 | 0 | default value 700 (too high temperature limit is 70.0 Celsius) | 1 | 2120 | This parameter determines the temperature at which the device sends a command to the associated device, to turn ON device or to turn OFF device. NOTE1: Too high temperature limit is used with Association Group 3. NOTE2: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 1 – 1000 (0.1 °C – 100.0 °C, resolution 0.1 °C) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 322 – 2120 (32.2 °F – 212.0 °F, resolution 0.1 °F) NOTE4: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. |
|
44 | Parameter no. 44 – Hysteresis Lower temperature offset | This parameter defines minimum temperature difference between real measured temperature and set-point temperature to turn device off in heat mode or turn device on in cool mode. Values (size is 2 byte dec): • default value 5 (0.5 °C) • 0 - 450 NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 0 – 250 (0.0 °C – 25.0 °C, resolution 0.1 °C) NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 0 – 450 (0.0 °F – 45.0 °F, resolution 0.1 °F) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. | 0 | 2 | 0 | 0 | 5 | From | To | Description |
|---|
0 | 450 | | 0 | 450 | This parameter defines minimum temperature difference between real measured temperature and set-point temperature to turn device off in heat mode or turn device on in cool mode. NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 0 – 250 (0.0 °C – 25.0 °C, resolution 0.1 °C) NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 0 – 450 (0.0 °F – 45.0 °F, resolution 0.1 °F) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. |
|
45 | Parameter no. 45 – Antifreeze | Set value determines at which temperature the device will be turned on even (if the thermostat was manually set to off). Values (size is 2 byte dec): • default value 50 (5.0 °C) • -125 - 545 • 1000 - Antifreeze functionality disabled NOTE1: Antifreeze is activated only in heating mode and it uses hysteresis of ±0.5°C. NOTE2: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is -125 – 125 (-12.5 °C – 12.5 °C, resolution 0.1 °C) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 95 – 545 (9.5 °F – 54.5 °F, resolution 0.1 °F) NOTE4: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. | 0 | 2 | 0 | 0 | 50 | From | To | Description |
|---|
0 | 0 | default value 50 (5.0 Celsius) | 1000 | 0 | Antifreeze functionality disabled. | -125 | 545 | Set value determines at which temperature the device will be turned on even (if the thermostat was manually set to off). NOTE1: Antifreeze is activated only in heating mode and it uses hysteresis of ±0.5°C. NOTE2: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is -125 – 125 (-12.5 °C – 12.5 °C, resolution 0.1 °C) NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 95 – 545 (9.5 °F – 54.5 °F, resolution 0.1 °F) NOTE4: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. |
|