| 3 | Time Interval for Auto Report | Time interval for auto report Respiratory rate. | 0 | 1 | 0 | 0 | 6 | | From | To | Description |
|---|
| 6 | 120 | Time interval (x5 seconds) | | 0 | 0 | Auto report off |
|
| 2 | Time Interval for Auto Report | Time interval for auto report Heart Rate. | 0 | 1 | 0 | 0 | 6 | | From | To | Description |
|---|
| 0 | 0 | Auto report off | | 6 | 120 | Time interval (x5 seconds) |
|
| 6 | High threshold for Heart Rate | The high threshold for Heart Rate will be used to automatically send Multilevel report of heart rate if the calculated heart rate goes over this value. | 0 | 2 | 0 | 0 | 100 | | From | To | Description |
|---|
| 0 | 0 | Threshold deactivated | | 1 | 200 | High-threshold |
|
| 1 | Power LED Control | Control the LED of the device. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 1 | 1 | LED On | | 0 | 0 | LED Off |
|
| 4 | Window Size | Averaging Window Size for Notification Report. | 0 | 1 | 0 | 0 | 3 | | From | To | Description |
|---|
| 1 | 8 | Window size interval (x5 seconds) |
|
| 5 | Threshold for Body/Respiratory ratio | The value of the Body/Respiratory ratio can take around 1000 to 8000. If there is no body motion, the value will be extremely near 1000. The default value of 2000 is typical for rolling over on bed (it depends on the person). This threshold is used for the event of the “Posture Change” of NOTIFICATION_REPORT. | 0 | 2 | 0 | 0 | 2000 | | From | To | Description |
|---|
| 1000 | 8000 | Threshold value |
|
| 7 | Low threshold for Heart Rate | The low threshold for Heart Rate will be used to automatically send Multilevel report of heart rate if the calculated heart rate goes below this value. | 0 | 2 | 0 | 0 | 60 | | From | To | Description |
|---|
| 0 | 0 | Threshold deactivated | | 1 | 200 | Low-threshold |
|
| 9 | Low threshold for Respiratory Rate | The low threshold for Respiratory Rate will be used to automatically send Multilevel report of Respiratory rate if the calculated Respiratory rate goes below this value. | 0 | 1 | 0 | 0 | 10 | | From | To | Description |
|---|
| 0 | 0 | Threshold deactivated | | 1 | 120 | Low-threshold |
|
| 10 | Sensor Setting | Sensor Sensitivity setting. If parameter 10 is set to 0 (high sensitivity mode), the sensor becomes more vulnerable to environmental noise. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | high | | 1 | 1 | low |
|
| 11 | Sensor Setting | Calibration mode setting. If parameter 11 is set to 0 (manual mode), the sensor will use preset values as thresholds for detecting Heart Rate / Respiratory Rate. If set to 1 (calibration mode), the sensor will use the calibrated values instead. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | manual | | 1 | 1 | calibration |
|