Product Recognition | |
|---|
Certification Number | ZC12-21090308 |
|---|
Name | homee Z-Wave 700 Series Cube |
|---|
Short Description | The Z-Wave™ Cube is a modular addition to the homee base cube - the "Brain Cube" |
|---|
Long Description | With Z-Wave™ Cube as a supplement to your Brain Cube you can control hundreds of smart home devices which use Z-Wave technology.
You could use Z-Wave™ Cube to control your blinds and roller shutters by making them smart with the Fibaro Roller Shutter2 insert switch. You can define times when heating should be tuned to any chosen comfort temperature, saving you money on heating - this is no problem with the Danfoss LC-13 radiator thermostat. Via our homeegrams, radiator thermostats can automatically be switched off once a window is opened, helping you to prevent energy waste. If security is your concern, you can add devices such as smoke detectors to your home, which alert you via push notification of fire or smoke, while also opening the blinds and turning on lights in order to create escape routes.
Once you leave your apartment, you can enable homeegrams alerting you if one of your door, window or motion sensors detect an unexpected event during your absence. Additionally, you could fire off an alarm siren like the Aeotec Siren. |
|---|
Brand | homee |
|---|
Product Identifier | HOMEE-005 |
|---|
Product Line | homee |
|---|
OEM Version | HW: 3 FW: 7.15:07.15 |
|---|
Hardware Platform | EFR32Z |
|---|
Z-Wave Version | 7.15.4 |
|---|
Library Type | CONTROLLER_BRIDGE |
|---|
Device Type | Gateway |
|---|
Role Type | ROLE_TYPE_CONTROLLER_CENTRAL_STATIC |
|---|
Manufacturer ID | 0x0456 |
|---|
Product Type ID | 0x0013 |
|---|
Product ID | 0x3800 |
|---|
User Icon | 0x0500 |
|---|
Installer Icon | 0x0500 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | All Controllers, Gateway Controller, Computer Controller Interfaces |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_NODE_PROVISIONING | Node Provisioning | 0x78 | 1 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_INCLUSION_CONTROLLER | Inclusion Controller | 0x74 | 1 | COMMAND_CLASS_ASSOCIATION_V3 | Association V3 | | 0 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V4 | Multi-Channel Association V4 | | 0 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_TIME | Time | 0x8A | 1 | COMMAND_CLASS_CRC_16_ENCAP | CRC16 Encapsulation | 0x56 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta-Data V5 | 0x7A | 5 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information V3 | 0x59 | 3 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_NETWORK_MANAGEMENT_BASIC_V2 | Network Management Basic V2 | 0x4D | 2 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CMD | Multi-Command | 0x8F | 1 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_NODE_PROVISIONING | Node Provisioning | 0x78 | 1 | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_SENSOR_ALARM | Sensor Alarm | 0x9C | 1 | COMMAND_CLASS_SWITCH_BINARY_V2 | Switch Binary V2 | 0x25 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_SWITCH_COLOR_V3 | Switch Color V3 | 0x33 | 3 | COMMAND_CLASS_ZIP_V4 | Z/IP V4 | | 0 | COMMAND_CLASS_DOOR_LOCK_V4 | Door Lock V4 | | 0 | COMMAND_CLASS_ASSOCIATION_V3 | Association V3 | | 0 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V4 | Multi-Channel Association V4 | | 0 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_THERMOSTAT_SETBACK | Thermostat Setback | 0x47 | 1 | COMMAND_CLASS_CRC_16_ENCAP | CRC16 Encapsulation | 0x56 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_SENSOR_BINARY_V2 | Sensor Binary V2 | 0x30 | 2 | COMMAND_CLASS_THERMOSTAT_MODE_V3 | Thermostat Mode V3 | 0x40 | 3 | COMMAND_CLASS_THERMOSTAT_SETPOINT_V3 | Thermostat Setpoint V3 | 0x43 | 3 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_ANTITHEFT_UNLOCK | Anti-Theft Unlock | | 0 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta-Data V5 | 0x7A | 5 | COMMAND_CLASS_MULTI_CHANNEL_V4 | Multi-Channel V4 | 0x60 | 4 | COMMAND_CLASS_THERMOSTAT_SETPOINT | Thermostat Setpoint | 0x43 | 1 | COMMAND_CLASS_SWITCH_MULTILEVEL_V4 | Switch Multilevel V4 | 0x26 | 4 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information V3 | 0x59 | 3 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_METER_V5 | Meter V5 | 0x32 | 5 | COMMAND_CLASS_NETWORK_MANAGEMENT_BASIC_V2 | Network Management Basic V2 | 0x4D | 2 | COMMAND_CLASS_SENSOR_MULTILEVEL_V11 | Sensor Multilevel V11 | 0x31 | 11 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_CENTRAL_SCENE_V3 | Central Scene V3 | 0x5B | 3 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED, S2_ACCESS_CONTROL |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product Manual | | Manual_English | Product Manual in English | |
|
|---|
Features | Feature | Values |
|---|
Gateway Has Preferred Partners | | Firmware Updatable | | Communications Protocol | Value |
|---|
Manufacturer Proprietary Protocol |
| Communications Connections | | Supported Notification Types | | Sensors | | Supported Meter Type | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Description |
|---|
1 | 1 | 0 | Lifeline | homee supports the association group 1 (Lifeline). A maximum number of 1 node can be added to this association group. The only event sent to this group is the device reset locally notification. |
|
|---|
Texts | ID | Description | Value |
|---|
3 | Controller Learn Mode | If the ZWave cube is reset to factory defaults, all connected Z Wave devices will be removed, and the cube gets a new Home ID. If homee is the primary controller for your network, resetting it will result in the nodes in your network being orphaned and it will be necessary after the reset to remove and add all of the nodes in the network.
If this controller is being used as a secondary controller in the network, use this procedure to reset this controller only in the event that the network primary controller is missing or otherwise inoperable. | 5 | Factory Reset Procedure | If the Z Wave cub e is reset to factory defaults, all connected Z Wave devices will be removed, and the cube gets a new Home ID. If homee is the primary controller for your network, resetting it will result in the nodes in your network being orphaned and it will be necessar y after the reset to remove and add all of the nodes in the network.
If this controller is being used as a secondary controller in the network, use this procedure to reset this controller only in the event that the network primary controller | 23 | Controller Classic Inclusion | Add Z-Wave Device (General) | 24 | Controller Classic Exclusion | Remove Z-Wave Device | 8 | Where to find S2 DSK on product | NOTE: The only way to see the DSK is via our app. The connection between our app and our
gateway is a secure websocket connection. The DSK is not pyhsically printed on the casing or packaging. | 11 | Controller SmartStart Inclusion | Add Z-Wave Device (SmartStart) | 10 | Controller Replication | If the ZWave cube is reset to factory defaults, all connected Z Wave devices will be removed, and the cube gets a new Home ID. If homee is the primary controller for your network, resetting it will result in the nodes in your network being orphaned and it will be necessary after the reset to remove and add all of the nodes in the network.
If this controller is being used as a secondary controller in the network, use this procedure to reset this controller only in the event that the network primary controller is missing or otherwise inoperable. | 25 | Controller Provisioning List | Add Z-Wave Device (SmartStart) | 9 | Capability Rediscovery | Node Rediscovery |
|
|---|
Supported / Controlled Meter Types | Meter Type | Rate Type | Description |
|---|
Electric meter | Import | Electric Meter Consumption |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|