| 3 | LED Light | When shipped from the factory, the LED is set to turn ON when the connected light is turned OFF. This is the default setting and can be changed if your primary controller supports the node configuration function. To make the LED turn ON when the light is turned ON, change parameter 3’s value to “1”. To turn the LED OFF at all times, change parameter 3’s value to 2. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 2 | 2 | LED light at all times | | 1 | 1 | LED light on when on | | 0 | 0 | Default |
|
| 4 | Invert Switch | If the switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4’s value to “1”. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 1 | Invert | | 0 | 0 | Default |
|
| 7 | Dim Rate Adjustments When receiving a Z-Wave Dim Command | number of steps or levels | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 1 | 99 | number of steps or levels | | 0 | 0 | |
|
| 8 | Dim Rate Adjustments When receiving a Z-Wave Dim Command | Timing of the steps. For values over 127, consult your controller's user guide; some controllers may require values above 127 to be entered using the 2's Complement value or using Hexadecimal notation. | 0 | 1 | 0 | 0 | 3 | | From | To | Description |
|---|
| 1 | 255 | Timing of the steps | | 0 | 0 | Instant |
|
| 9 | Dim Rate Adjustments When manually controlling dimming | number of steps or levels | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 1 | 99 | number of steps or levels | | 0 | 0 | |
|
| 10 | Dim Rate Adjustments When manually controlling dimming | Dim Rate Adjustments When manually controlling dimming. For values over 127, consult your controller's user guide; some controllers may require values above 127 to be entered using the 2's Complement value or using Hexadecimal notation. | 0 | 1 | 0 | 0 | 3 | | From | To | Description |
|---|
| 0 | 0 | | | 1 | 255 | timing of the steps |
|
| 11 | Dim Rate Adjustments When receiving an All-On or All-Off command | Dim Rate Adjustments When receiving an All-On or All-Off command | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 1 | 99 | number of steps or levels | | 0 | 0 | |
|