| Product Recognition | |
|---|
| Certification Number | ZC10-16055066 |
|---|
| Name | IN-Wall Smart Meter TR Duplex Receptacle |
|---|
| Short Description | IN-Wall Smart Meter TR Duplex Receptacle |
|---|
| Long Description | The ZW15RM TR Duplex Receptacle is a perfect wireless manual and remote on/off control replacement of regular receptacles, controlling table and floor lamps, small appliances, etc. It provides two different type outlets. One outlet with Z-Wave mark has programmable functions such as scenes, association, schedule event, etc. It is fully interoperable with other Z-Wave certified device from other manufacturers and/or other applications. It can report wattage energy usage or kWh energy usage to a Z-Wave gateway.It has a Blue LED on the face cover indicates the status of the controlled outlet and/or act as a night light. The other outlet with Tamper-Resistant feature provides constant power, helps you and your families prevent electrical injuries. |
|---|
| Brand | Enerwave Green Automation |
|---|
| Product Identifier | ZW15RM |
|---|
| OEM Version | HW: 1 FW: 5.10 |
|---|
| Hardware Platform | ZM5202 |
|---|
| Z-Wave Version | 6.51.07 |
|---|
| Library Type | SLAVE_ROUTING |
|---|
| Device Type | On/Off Power Switch |
|---|
| Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
| Manufacturer ID | 0x011A |
|---|
| Product Type ID | 0x0111 |
|---|
| Product ID | 0x0105 |
|---|
| User Icon | 0x0700 |
|---|
| Installer Icon | 0x0700 |
|---|
| Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
| Categories | Energy Meters, All Lighting Devices, On/Off Switches/Devices |
|---|
| Countries / Regions | United States of America |
|---|
| Documents | |
|---|
| Features | | Feature | Values |
|---|
| Supported Meter Type | | | Switch Type | | Value |
|---|
| Push Button with Indicator |
|
|
|---|
| Association Groups | | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
| 1 | 1 | 0 | Lifeline: Send device reset locally notification | | 2 | 5 | 0 | StatusReport: Send basic report | | 3 | 5 | 0 | PowerReport: Send meter power report |
|
|---|
| Configuration Parameters | | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
| 1 | LEDdirect | synchronization of outlet power and LED indicator | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | Power on, LED off | | 1 | 1 | Power on, LED on |
|
|
|---|
| Texts | | ID | Description | Value |
|---|
| 1 | Inclusion | When the controller is in add mode and the blue LED is blinking on the
ZW15RM, press and hold the program button of ZW15RM for 3 second, and
then the controller will verify the add. | | 2 | Exclusion | When the controller is in remove mode, press and hold the program button of
ZW15RM for 3 second, and then the controller will remove it from the current
Z-Wave network, and the LED will blink on the receptacle,when power on. | | 5 | Factory Reset | Once program button is pressed and hold for 10 second, the device will send a device reset locally notification to controller. Then clear all of information for
the network, and restore factory defaults, and reset the module. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. |
|
|---|
| Supported / Controlled Meter Types | | Meter Type | Rate Type | Description |
|---|
| Electric meter | Import | Electric Meter Consumption |
|
|---|
| Supports NWI | Yes |
|---|
| Supports Explorer Frames | Yes |
|---|