Product Recognition | |
|---|
Certification Number | ZC10-18126337 |
|---|
Name | Motion Sensor |
|---|
Short Description | Eaton's Z-Wave Plus battery operated motion sensor is a versatile motion detector that can be triggered by movement or changes in light level when paired with your Home automation or a Security system. |
|---|
Long Description | Eaton's Z-Wave Plus battery operated motion sensor is a versatile motion detector that can be triggered by movement or changes in light level when paired with your Home automation or a Security system.
• Detects motion in a space with in-built Passive Infra-red and Light Sensor
• When used with a compatible Smart Hub, get alerted on your smart phone or Tablet, trigger scenes or have lights come ON automatically
• CR123A Lithium Battery included with the product ~ expected battery life of 2 years
• Can be mounted using included screws or double sided tape
• 120° field of view with 1032 sq. ft coverage for Major motion
• Supports Z-Wave Plus functionality with S2 security certification |
|---|
Brand | Eaton |
|---|
Product Identifier | RF96PIRBMS |
|---|
OEM Version | HW: 1 FW: 1.00:00.05 |
|---|
Hardware Platform | SD3502 |
|---|
Z-Wave Version | 6.71.01 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x001A |
|---|
Product Type ID | 0x0042 |
|---|
Product ID | 0x0053 |
|---|
User Icon | 0x0C07 |
|---|
Installer Icon | 0x0C07 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
Categories | Sensors, Lighting Accessories, Security Add-Ons |
|---|
Countries / Regions | United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 | Firmware Update Meta-Data V4 | 0x7A | 4 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC | Basic | 0x20 | 1 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Quantity | | Supported Notification Types | | Battery Type | | Color | | Sensors | Value |
|---|
Motion/No Motion (Binary) | Luminance |
| Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
2 | 4 | 0 | Basic Set
PIR Control | 1 | 5 | 0 | Z-Wave Plus Lifeline |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
1 | Basic Set Level | The Basic Set Level determines the value that will be sent from the Basic Set command for devices associated with Group 2. For a Binary Switch Device (e.g., receptacle or appliance module), it will be a simple ON command. For a Multilevel Switch Device (e.g., a dimmer), it will be set to the level set by this parameter. | 0 | 1 | 0 | 0 | 99 | From | To | Description |
|---|
1 | 99 | Basic Set Level |
| 3 | Sensitivity level | In order to provide the best efficiency of the sensor, it is recommended to test the sensor with movements from the farthest end of the coverage area at first time of use. If movements cannot be detected consistently, simply adjust the sensitivity level with Configuration Parameter #3. This parameter can be configured with the value of 1 through 10, where 1 means low sensitivity and 10 means high sensitivity. | 0 | 1 | 0 | 0 | 6 | From | To | Description |
|---|
1 | 10 | Sensitivity level low (1) to high (10) |
| 4 | Re-trigger Interval | The Re-trigger Interval Setting determines the amount of time between when the sensor will retrigger a signal that motion has been detected. During this time, the sensor will not report motion even though motion may be detected. The time interval can be set between 5 secs to 3600 secs. | 0 | 1 | 0 | 0 | 180 | From | To | Description |
|---|
5 | 3600 | Time in seconds |
|
|
|---|
Texts | ID | Description | Value |
|---|
4 | Device Wake-Up | After it has been included into a Z-Wave network, the sensor will go to sleep but will send a Wakeup
Notification Command periodically at preset interval to the controller. The Motion sensor will stay
awake for at least 10 seconds and then go back to sleep to conserve battery life.
The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class
based on the range values below:
Minimum Wake Up Interval: 600s (10 minutes)
Maximum Wake Up Interval: 86400s (1 day)
Default Wake Up Interval: 14400s (4 hours)
Wake Up Interval Step Seconds: 600s (10 minutes) | 5 | Factory Reset | This procedure should only be used when the controller is inoperable:
1. Press the tamper switch 3 times within 1.5
seconds to put the unit into exclusion mode
2. Within 1 second of step 1, press the tamper switch
again and hold until LED is off (about 5 seconds)
3. Node ID is excluded. The device reverts to factory
default state and will be in auto-inclusion mode for
4 minutes | 6 | Additional Special Features | The sensor reports battery level. Following are the values:
20 - 100 will be displayed as battery %
0xFF indicates low battery | 1 | Inclusion | The sensor supports Auto Inclusion feature where it will automatically enter Inclusion mode when first
powered up after a factory reset.
1. Use a screwdriver to detach the rear cover.
2. Put a Z-Wave Controller into inclusion mode.
3. Insert 1 CR123 3V battery to the battery compartment with the correct polarity. The LED on the device should turn ON.
4. The Inclusion process should be completed when the LED stops blinking.
5. Do not refit the rear cover yet and proceed to the Testing section before mounting.
Note: If Auto Inclusion fails, refer to the Troubleshooting section regarding Manual Inclusion.
1. Put the Z-Wave Controller into Inclusion mode
2. Press the tamper switch 3 times within 1.5
seconds to put the unit into inclusion mode | 2 | Exclusion | 1. Put the Z-Wave Controller into Exclusion mode
2. Press the tamper switch 3 times within 1.5
seconds to put the unit into exclusion mode |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Light sensor | (Refer to parameters): State idle | Light sensor | Light detection status: Light detected | Light sensor | Light color transition detected |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
General purpose | Illuminance |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|