Product Recognition | |
|---|
Certification Number | ZC14-24080464 |
|---|
Name | Motion Sensor |
|---|
Short Description | Use this Z-Wave Long Range Motion Sensor to reliable detect and report motion and vibration activity. |
|---|
Long Description | PRODUCT FEATURES:
• Fast, reliable motion detection
• Built-in vibration sensor
• NEW 800 series chip for faster and safer wireless communication
• NEW Z-Wave Long Range for ultra reliable no-mesh communication
• Latest S2 security protocol and AES-128 signal encryption
• 2 alternative power sources: battery or micro USB
• SmartStart for instant set-up
• Magnetic mount for quick and flexible installation
• Adjustable LED indicator
• Low battery alerts
PRODUCT SPECS:
• Model Number: ZSE18 800LR
• Z-Wave Region: US/CA/MX
• Power: 1 CR123A battery (3V) or micro USB (cable not included)
• Z-Wave Range: Up to 150 feet (up to 1300 feet with Long Range enabled)
• Operating Temp.: 32-104° F
• Installation and Use: Indoor only |
|---|
Brand | ZOOZ |
|---|
Product Identifier | ZSE18 800LR |
|---|
Product Line | Smart Sensor |
|---|
OEM Version | HW: 02 FW: 02.00 |
|---|
Hardware Platform | EFR32ZG23A |
|---|
Z-Wave Version | 7.19.3 |
|---|
Library Type | END_NODE_ENHANCED_232 |
|---|
Device Type | Notification Sensor DT |
|---|
Role Type | ROLE_TYPE_END_NODE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x027A |
|---|
Product Type ID | 0x0301 |
|---|
Product ID | 0x0012 |
|---|
User Icon | 0x0C07 |
|---|
Installer Icon | 0x0C07 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz, US_LR: 912.00MHz, 920.00MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | Canada, United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_SECURITY | Security 0 | 0x98 | 1 | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 |
|
|---|
S2 Classes | S2_AUTHENTICATED, S2_UNAUTHENTICATED |
|---|
Documents | Category | File |
|---|
Manual_English | |
|
|---|
Features | Feature | Values |
|---|
Battery Quantity | | Battery Type | | Color | | Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
1 | 5 | 0 | Lifeline | 0x0001 | 2 | 5 | 0 | On/Off control | 0x7107 |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
|---|
17 | Vibration sensor enable or disable | Vibration sensor enable or disable | 2 | 1 | 0 | 0 | 0x01 | 254 | Configuration param lock | Configuration param lock | 2 | 1 | 0 | 0 | 0x00 |
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | If you’re using an S2 hub, it will ask you to enter the DSK PIN or scan the QR code printed on the inside of the back cover of the sensor to complete SmartStart inclusion. | 1 | Classic Inclusion | 1. Initiate inclusion (pairing) in the app (or web interface).
2. CLICK Z-WAVE BUTTON 3 TIMES QUICKLY if using traditional Z-Wave inclusion.
3. The LED indicator will blink to signal communication and turn solid if inclusion is successful. | 2 | Classic Exclusion | 1. Initiate exclusion (unpairing) in the app (or web interface).
2. CLICK Z-WAVE BUTTON 3 TIMES QUICKLY if using traditional Z-Wave inclusion.
3. The LED indicator will blink to signal communication and turn solid if exclusion is successful. | 4 | Wake-Up Procedure | Press & HOLD the Z-Wave® button for 5 seconds to wake the device up. The LED will start flashing. | 5 | Factory Reset Procedure | If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, press and HOLD the Z-Wave
® button on the sensor for at least 20 seconds. The LED indicator will flash, stay solid, and then turn off to confirm factory reset.
NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Home Security | (Refer to parameters): State idle | Home Security | Cover status: Tampering, product cover removed | Home Security | Motion sensor status: Motion detection | Power Management | Mains status: AC mains disconnected | Power Management | Mains status: AC mains re-connected |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|
Radio Range Z-Wave LR (m) | 400 |
|---|