| 170 | No.170 SET PARAMETER 171 – 174 TO DEFAULT SETTINGS | Set parameter 171,172,173,174 to default settings | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 85 | 85 | Set parameter 171,172,173,174 to default settings |
|
| 171 | BATTERY REPORT INTERVAL | The interval of sending battery report to association device (Group Lifeline). The reports are sent even if there are no changes in the battery level. | 0 | 4 | 0 | 0 | 1800 | | From | To | Description |
|---|
| 5 | 2678400 | The interval of sending battery report |
|
| 172 | TEMPERATURE REPORT INTERVAL | The interval of sending temperature report to association device (Group Lifeline). The reports are sent even if there are no changes in the temperature level. | 0 | 4 | 0 | 0 | 1800 | | From | To | Description |
|---|
| 5 | 2678400 | The interval of sending temperature report |
|
| 173 | HUMIDITY REPORT INTERVAL | The interval of sending Humidity report to association device (Group Lifeline). The reports are sent even if there are no changes in the humidity level. | 0 | 4 | 0 | 0 | 1800 | | From | To | Description |
|---|
| 5 | 2678400 | The interval of sending Humidity report |
|
| 174 | LUMINANCE REPORT INTERVAL | The interval of sending luminance report to association device (Group Lifeline). The reports are sent even if there are no changes in the luminance level. | 0 | 4 | 0 | 0 | 1800 | | From | To | Description |
|---|
| 5 | 2678400 | The interval of sending luminance report |
|
| 181 | BATTERY REPORT THRESHOLD | The parameter determines the change in battery level resulting in battery report being sent to the main controller. | 0 | 1 | 0 | 0 | 10 | | From | To | Description |
|---|
| 0 | 100 | the change in battery level resulting in battery report being sent to the main controller. |
|
| 183 | HUMITIDY REPORT THRESHOLD | The parameter determines the change in humidity level resulting in humidity report being sent to the main controller. | 0 | 1 | 0 | 0 | 5 | | From | To | Description |
|---|
| 0 | 0 | reports are not sent | | 1 | 255 | the change in humidity level resulting in humidity report being sent to the main controller. |
|
| 184 | LUMINANCE REPORT THRESHOLD | The parameter determines the change in luminance level resulting in luminance report being sent to the main controller. | 0 | 2 | 0 | 0 | 200 | | From | To | Description |
|---|
| 0 | 0 | Reports are not sent | | 1 | 65535 | the change in luminance level resulting in luminance report being sent to the main controller. |
|