| 1 | Beaming Enable/Disable | Used to enable/disable beaming. If set to 1, FLiR commands will be supported. But the device must be re-included into the network to activate it. 0 - disable 1 - enable | 2 | 1 | 0 | 0 | 0x01 | |
| 2 | Motion Retrigger Time | Presence re-detection time set in second to allow motion sensor to reset timeout of motion sensor. In this time, the motion sensor can not be triggered again. If this value reach zero, the timeout configuration value set by Param3 will be reset. This setting value must always be less than timeout configuration. 0 - disable 1~3600 - timeout set in seconds | 1 | 2 | 0 | 0 | 0x001E | |
| 3 | Motion Untrigger Time | Timeout configuration set in second for motion sensor to send no trigger status. | 1 | 2 | 0 | 0 | 0x00F0 | |
| 4 | Motion Sensitivity | Set the sensitivity of motion sensor. 0 - disable 1- minimum sensitivity 11 - maximum sensitivity | 1 | 1 | 0 | 0 | 0x0B | |
| 5 | Motion Report Type | Set which command class will be sent when motion sensor is triggered or detriggered. 0 - Sends Notification Report 1 - Sends Sensor Binary Report 2 - Sends Notification and Sensor Binary Report | 2 | 1 | 0 | 0 | 0x02 | |
| 6 | Vibration Sensor Enable/Disable | Used to enable/disable vibration sensor. 0 - disable vibration 1~254 - timeout set in minutes to reset vibration status 255 - only send vibration triggered, does not timeout | 1 | 1 | 0 | 0 | 0xFF | |
| 7 | Vibration Intensity Reports | Used to enable/disable vibration intensity reports. If set to 1, vibration intensity will be sent to gateway when triggered. If set to 0, do not report. | 2 | 1 | 0 | 0 | 0x00 | |
| 9 | Wakeup CC Timeout | Timeout set in seconds after Wakeup CC is send out before go to sleep. If wakeup no more information received, return to sleep mode immediately. | 1 | 1 | 0 | 0 | 0x0F | |
| 10 | Power Status | This value is Readonly. Used to report the power status (USB or Battery powered) 0 - When battery powered, the device will act as RSS. 1 - When USB cable insert, the device will act as LSS. The device must be re-included in the network to change the role type. | 2 | 1 | 0 | 0 | 0x00 | Yes |
| 11 | Motion Group Control(Group2) | Set control of other devices on group2 based on motion trigger. 0 - Send BASIC_SET (0xFF) when motion is triggered to associated device Send BASIC_SET (0x00) when motion is untriggered to associated device 1 - Send BASIC_SET (0x00) when motion is triggered Send BASIC_SET (0xFF) when motion is untriggered 2 - Send BASIC_SET (0xFF) when motion is triggered, Nothing when motion untriggered. 3 - Send BASIC_SET (0x00) when motion is triggered, Nothing when motion untriggered. 4 - Send BASIC_SET (0x00) when motion is untriggered, Nothing when motion triggered. 5 - Send BASIC_SET (0xFF) when motion is untriggered, Nothing when motion triggered. 6 - Send BASIC_SET (value is configured by parameter 12) when motion is triggered to associated devices. Send BASIC_SET (value is configured by parameter 12) when motion is untriggered. | 2 | 1 | 0 | 0 | 0x00 | |
| 17 | Under Heat Group Threshold (Group4) | Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature (this value) send BASIC_SET (0x00) to associated devices. E.g. Value 155 means 15.5 C. Value 600 means 60.0 F. | 0 | 2 | 0 | 0 | 0x009B | |
| 40 | Threshold Check Enable/Disable | Enable/Disable threshold reporting, check time can be adjusted by Param45. 0 - disable all threshold reports 1 - enable all threshold reports | 2 | 1 | 0 | 0 | 0x00 | |
| 41 | Temperature Threshold | Threshold = (Value * 0.1) Scale is determined by Param64. 0 = disable. | 1 | 1 | 0 | 0 | 0x0A | |
| 42 | Humidity Threshold | Humidity range = 1% to 50%, 0 = disable. | 1 | 1 | 0 | 0 | 0x05 | |
| 43 | Lux Threshold | 0 = disable | 1 | 2 | 0 | 0 | 0x00FA | |
| 44 | UV Threshold | 0 = disable | 1 | 1 | 0 | 0 | 0x01 | |
| 45 | Threshold Check Time | Set threshold check time in seconds if threshold is enable via Param40. 1~65535 - When USB powered 60~65535 - When Battery powered | 1 | 2 | 0 | 0 | 0x00F0 | |
| 46 | Low Temperature Report | Eable/Disable alarm report for low temperature( | 2 | 1 | 0 | 0 | 0x01 | |
| 48 | Sensor Limit Control | This value is bit mask. Used to enable/disable measurement reports for various sensors that is more than the upper limit value or less than the lower limit value. 1 - Temperature upper level 2 - Humidity upper level 4 - Lux upper level 8 - UV upper level 16 - Temperature lower level 32 - Humidity lower level 64 - Lux lower level 128 - UV lower level | 3 | 1 | 0 | 0 | 0x00 | |
| 49 | Temperature Upper Limit | Set upper limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current measurement) > (Upper Limit), then report sensor. | 0 | 2 | 0 | 0 | 0x0118 | |
| 50 | Temperature Lower Limit | Set lower limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current Measurement) < (Lower limit), then report sensor. | 0 | 2 | 0 | 0 | 0x0000 | |
| 51 | Temperature Recover Limit | Temperature recover limit set in scale of 0.1. Scale is determined by Param64. If (Current measurement) = (lower limit + recover limit), then temperature report. | 1 | 1 | 0 | 0 | 0x14 | |
| 52 | Humidity Upper Limit | Set humidity upper limit level. | 1 | 1 | 0 | 0 | 0x3C | |
| 53 | Humidity Lower Limit | Set humidity lower limit level | 1 | 1 | 0 | 0 | 0x28 | |
| 54 | Humidity Recover Limit | Set humidity recover limit level. Refer to Param 51. | 1 | 1 | 0 | 0 | 0x05 | |
| 55 | Lux Upper Limit | Set lux upper limit level. | 1 | 2 | 0 | 0 | 0x03E8 | |
| 56 | Lux Lower Limit | Set lux lower limit level. | 1 | 2 | 0 | 0 | 0x0064 | |
| 67 | Lux Recover Limit | Set lux recover limit level. Refer to Param 51. | 1 | 1 | 0 | 0 | 0x64 | |
| 58 | UV Upper Limit | Set UV upper limit level. | 1 | 1 | 0 | 0 | 0x08 | |
| 59 | UV Lower Limit | Set UV lower limit level. | 1 | 1 | 0 | 0 | 0x04 | |
| 60 | UV Recover Limit | Set UV recover limit level. Refer to Param 51. | 1 | 1 | 0 | 0 | 0x01 | |
| 61 | Out-of-limit State | This is read only and bit mask. Out of the limit state of sensors. Bit Mask: 0 - within limit 1 - out of limit Value: 1 - Temperature upper level 2 - Humidity upper level 4 - Lux upper level 8 - UV upper level 16 - Temperature lower level 32 - Humidity lower level 64 - Lux lower level 128 - UV lower level | 3 | 1 | 0 | 0 | 0x00 | Yes |
| 64 | Temperature Scale | Set the scale for temperature when reports. 0 - Celsius 1 - Fahrenheit | 2 | 1 | 0 | 0 | 0x00 | |
| 81 | LED Activity | Allow user to enable/disable LED activity of specific reports sent by sensor. Button press indicator is not affected by this. 0 - disable 1 - enable | 2 | 1 | 0 | 0 | 0x01 | |
| 82 | Motion Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of motion sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | 2 | 1 | 0 | 0 | 0x03 | |
| 83 | Temperature Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of temperature sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | 2 | 1 | 0 | 0 | 0x00 | |
| 84 | Humidity Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of humidity sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | 2 | 1 | 0 | 0 | 0x00 | |
| 85 | Lux Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of Lux sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | 2 | 1 | 0 | 0 | 0x00 | |
| 86 | UV Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of UV sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | 2 | 1 | 0 | 0 | 0x00 | |
| 87 | Vibration Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of vibration sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | 2 | 1 | 0 | 0 | 0x02 | |
| 88 | Battery Report Indicator | If LED is enabled by Param81, allow user to change the report color of battery. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | 2 | 1 | 0 | 0 | 0x00 | |
| 89 | Wakeup Report Indicator | If LED is enabled by Param81, allow user to change the report color of wakeup. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | 2 | 1 | 0 | 0 | 0x08 | |
| 90 | Communication Indicator | If LED is enabled by Param81, allow user to change indicator color when receiving communication from gateway or other devices. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | 2 | 1 | 0 | 0 | 0x00 | |
| 101 | Automatic Report Checklist 1 | Checklist 1 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param111. 1 - Battery 16 - UV 32 - Temperature 64 - Humidity 128 - Lux | 3 | 1 | 0 | 0 | 0xF1 | |
| 102 | Automatic Report Checklist 2 | Checklist 2 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param112. 1 - Battery 16 - UV 32 - Temperature 64 - Humidity 128 - Lux | 3 | 1 | 0 | 0 | 0x00 | |
| 103 | Automatic Report Checklist 3 | Checklist 3 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param113. 1 - Battery 16 - UV 32 - Temperature 64 - Humidity 128 - Lux | 3 | 1 | 0 | 0 | 0x00 | |
| 111 | Automatic Checklist 1 Interval Time | Interval time set in seconds to check the checklist1’s items. Multilevel Sensor Report will be sent when timeout. | 1 | 2 | 0 | 0 | 0x0E10 | |
| 112 | Automatic Checklist 2 Interval Time | Interval time set in seconds to check the checklist2’s items. Multilevel Sensor Report will be sent when timeout. | 1 | 2 | 0 | 0 | 0x0E10 | |
| 113 | Automatic Checklist 3 Interval Time | Interval time set in seconds to check the checklist3’s items. Multilevel Sensor Report will be sent when timeout. | 1 | 2 | 0 | 0 | 0x0E10 | |
| 201 | Temperature Offset Value | Can add or minus this setting value to calibrate temperature when checked. Scale is defined by Param64. e.g. Value 15 means 1.5C or 1.5F. | 0 | 2 | 0 | 0 | 0x0000 | |
| 202 | Humidity Offset Value | Can add or minus this setting value to calibrate humidity when checked. Unit: %. | 0 | 1 | 0 | 0 | 0x00 | |
| 203 | Lux Offset Value | Can add or minus this setting value to calibrate Lux when checked. | 0 | 2 | 0 | 0 | 0x0000 | |
| 204 | UV Offset Value | Can add or minus this setting value to calibrate UV when checked. | 0 | 1 | 0 | 0 | 0x00 | |