| Product Recognition | |
|---|
| Certification Number | ZC14-26010580 |
|---|
| Name | MultiSensor 8 |
|---|
| Short Description | Aeotec MultiSensor 8 |
|---|
| Description | Aeotec MultiSensor 8 adopts Z-Wave® technology and is an intelligent wireless sensor device that integrates motion, temperature, humidity, light and acceleration sensors. The product supports battery or USB power supply. The installation methods include ceiling installation and wall mounted installation, and the sensitivity of motion sensor is also adjustable.
This product supports Security 2 Command Class. While a Security S2 enabled Controller is needed in order to fully use the security feature. This product can be operated in any Z-Wave network with other Z-Wave/ Z-Wave Plus® certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. This product also supports SmartStart. |
|---|
| Brand | Aeotec |
|---|
| Brand Owner | Aeotec Limited |
|---|
| Identifier | ZWA066-C |
|---|
| Product Line | Z-Wave Plus v2 line |
|---|
| Product URL | www.aeotec.com |
|---|
| OEM Version | HW: 66 FW: 01.00 |
|---|
| Hardware Platform | EFR32ZG23A |
|---|
| Z-Wave Version | 7.23.2 |
|---|
| Library Type | END_NODE_ENHANCED_232 |
|---|
| Device Type | Notification Sensor DT |
|---|
| Role Type | ROLE_TYPE_END_NODE_ALWAYS_ON, ROLE_TYPE_END_NODE_SLEEPING_REPORTING |
|---|
| Manufacturer ID | 0x0371 |
|---|
| Product Type ID | 0x0002 |
|---|
| Product ID | 0x0042 |
|---|
| User Icon | 0x0C07 |
|---|
| Installer Icon | 0x0C07 |
|---|
| Radio Range Z-Wave (m) | 40 |
|---|
| Radio Range Z-Wave LR (m) | 400 |
|---|
| Frequency Plans | EU: 869.85MHz, 868.40MHz, EU_LR: 864.00MHz, 866.00MHz |
|---|
| Categories | Sensors |
|---|
| Countries / Regions | Armenia, Bahrain, European Union, Cyprus, Moldova, Egypt, French Guiana, Georgia, Iraq, Jordan, Kazakhstan, Kuwait, Lebanon, Libya, Maldives, Mauritius, Nigeria, Oman, Philippines, Qatar, Saudi Arabia, South Africa, Turkmenistan, United Arab Emirates, ZU, Yemen |
|---|
| Supported Command Classes | | Identifier | Name | Key | Version |
|---|
| COMMAND_CLASS_SENSOR_BINARY_V2 | Binary Sensor V2 | 0x30 | 2 | | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | | COMMAND_CLASS_SENSOR_MULTILEVEL_V11 | Multilevel Sensor V11 | 0x31 | 11 | | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 |
|
|---|
| S2 Classes | S2_AUTHENTICATED, S2_UNAUTHENTICATED |
|---|
| Documents | |
|---|
| Features | | Feature | Values |
|---|
| Battery Quantity | | | Battery Type | | | Color | | | Firmware Updatable | | Value |
|---|
| Updatable by Consumer by RF |
|
|
|---|
| Association Groups | | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
| 1 | 5 | 0 | Lifeline | 0x0001 | | 2 | 5 | 0 | Motion | 0x7107 | | 3 | 5 | 0 | Over Heat | 0x3101 | | 4 | 5 | 0 | Under Heat | 0x3101 | | 5 | 5 | 0 | Over Humidity | 0x3105 | | 6 | 5 | 0 | Under Humidity | 0x3105 | | 7 | 5 | 0 | Over Light | 0x3103 | | 8 | 5 | 0 | Under Light | 0x3103 | | 9 | 5 | 0 | Mold danger | 0x7110 | | 10 | 5 | 0 | Temperature | 0x3101 | | 11 | 5 | 0 | Tamper | 0x7107 |
|
|---|
| Configuration Parameters | | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
|---|
| 1 | Enable Binary Sensor Report | For motion state | 2 | 1 | 0 | 0 | 0x00 | | 2 | Motion Retrigger Time | Motion re-detection time | 1 | 2 | 0 | 0 | 0x00F0 | | 3 | Motion Untrigger Time | Motion event release delay time | 1 | 2 | 0 | 0 | 0x0000 | | 4 | Motion sensitivity | Sensitivity of motion sensor | 1 | 1 | 0 | 0 | 0x0B | | 5 | Motion Group Control Requirement | Motion Group Control Requirement | 1 | 2 | 0 | 0 | 0x7530 | | 6 | Tamper Report Enable/Disable | Used to enable/disable tamper report | 1 | 1 | 0 | 0 | 0x04 | | 7 | Minimum acceleration change to report | Trigger acceleration report | 1 | 1 | 0 | 0 | 0x00 | | 8 | Motion Group Control Group2 | Motion Group Control Group2 | 2 | 1 | 0 | 0 | 0x00 | | 9 | Motion Group Value Setting | Motion Group Value Setting | 1 | 2 | 0 | 0 | 0xFF00 | | 10 | Temperature & Dew Point Scale | scale for auto reports and setting | 2 | 1 | 0 | 0 | 0x00 | | 11 | Threshold Check Time | Set threshold Check Time | 1 | 2 | 0 | 0 | 0x0000 | | 17 | Under Humidity Group Threshold Group6 | Under Humidity Group Threshold | 1 | 1 | 0 | 0 | 0x28 | | 23 | Temperature Threshold | Minimum temperature change to report | 1 | 1 | 0 | 0 | 0x0A | | 24 | Humidity Threshold | Minimum humidity change to report | 1 | 1 | 0 | 0 | 0x05 | | 25 | Lux Threshold | Minimum Lux change to report | 1 | 2 | 0 | 0 | 0x00FA | | 31 | Report Indicator | Report Indicator | 1 | 4 | 0 | 0 | 0x00032140 |
|
|---|
| Texts | | ID | Description | Value |
|---|
| 8 | Where to find S2 DSK on product | Page 4 in the Manual | | 1 | Classic Inclusion | 1. Turn your main controller/ gateway into adding/ inclusion mode.
2. Press the Action Button on product twice quickly. | | 2 | Classic Exclusion | 1. Turn your main controller/ gateway into removing/ exclusion mode.
2. Press the Action Button on product twice quickly. | | 4 | Wake-Up Procedure | Click the button once. | | 5 | Factory Reset Procedure | Press and hold the action button for at least 12 seconds. |
|
|---|
| Supported Notification Types | | Notification Type | Event / State |
|---|
| Heat Alarm | (Refer to parameters): State idle | | Heat Alarm | Heat sensor status: Overheat detected | | Heat Alarm | Heat sensor status: Under heat detected | | Home Security | (Refer to parameters): State idle | | Home Security | Cover status: Tampering, product cover removed | | Home Security | Motion sensor status: Motion detection | | Power Management | (Refer to parameters): State idle | | Power Management | Power status: Power has been applied | | Power Management | Mains status: AC mains disconnected | | Power Management | Mains status: AC mains re-connected | | Power Management | Battery maintenance status: Replace battery now | | Weather Alarm | (Refer to parameters): State idle | | Weather Alarm | Moisture alarm status: Moisture alarm |
|
|---|
| Supported Multilevel Sensors | | Multilevel Sensor Type |
|---|
| Air temperature | | Illuminance | | Humidity | | Dew point | | Acceleration X-axis | | Acceleration Y-axis | | Acceleration Z-axis |
|
|---|
| Supports NWI | Yes |
|---|
| Supports Explorer Frames | Yes |
|---|
| Supports SmartStart | Yes |
|---|