Product Recognition | |
|---|
Certification Number | ZC14-22020058 |
|---|
Name | Ness Z-Wave Door Strike Controller |
|---|
Short Description | Ness Z-Wave™ Door Lock Controller (DLC) is a unique access control accessory providing a smart relay output and door position sensor inputs. |
|---|
Description | Ness Z-Wave™ Door Lock Controller (DLC) is a unique access control accessory providing a smart relay output and door position sensor inputs.
DLC provides one relay output and one 12V DC power output for connection to existing devices such as an electric door strike, electromechanical lock, magnetic lock, garage door and gate etc., any of which can be operated remotely via Z-Wave™ wireless control commands.
The Ness Z-Wave™ Door Strike Controller is powered by a rechargeable 18650 Li-Ion battery or external USB (C type connector) power. The rechargeable 18650 Li-Ion battery will be recharged once the USB power cable has been connected.
Two pairs of external terminals are used to accept wired door position sensors such as reed switches or the request To Exit (REX) button. The function of each external terminal is configurable via Z-Wave™ configuration command class.
Ness DLC is a Security Enabled Z-Wave Plus™ V2 product empowered wireless control. This product can be operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers with the same region radiofrequency. All mains operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. |
|---|
Brand | Ness |
|---|
Identifier | ZA-116001 |
|---|
Product Line | Entry controller |
|---|
OEM Version | HW: 01 FW: 01.03 |
|---|
Hardware Platform | ZGM130S037HGN2 / ZGM130S037HGN1 |
|---|
Z-Wave Version | 7.15.4 |
|---|
Library Type | END_NODE_ENHANCED_232 |
|---|
Device Type | Lock DT |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_LISTENING |
|---|
Manufacturer ID | 0x0189 |
|---|
Product Type ID | 0x0204 |
|---|
Product ID | 0x0101 |
|---|
User Icon | 0x0300 |
|---|
Installer Icon | 0x0300 |
|---|
Radio Range Z-Wave (m) | 40 |
|---|
Frequency Plans | ANZ: 919.80MHz, 921.40MHz |
|---|
Categories | Locks |
|---|
Countries / Regions | Australia, New Zealand |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_DOOR_LOCK_V4 | Door Lock V4 | 0x62 | 4 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_SECURITY | Security 0 | 0x98 | 1 | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 |
|
|---|
S2 Classes | S2_ACCESS_CONTROL |
|---|
Documents | Category | File |
|---|
Adv_Manual | | Manual_English | |
|
|---|
Features | |
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
1 | 5 | 0 | Lifeline | 0x0001 |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
|---|
1 | The Relock Timer | Sets the output duration for the RELAY Output and the 12V Lock Output. Output ON duration in seconds. Range: 0 ~ 300. Default value: 10. 0 = Latching Operation. | 1 | 2 | 0 | 0 | 0x000A | 2 | Function Options for Input Terminal SW1 | Range: 0 ~ 3. Default: 2. Value = 0: The input is disabled. Value = 1: Normally Closed Door sensor. Value = 2: Normally Open Door sensor. Value = 3: External unlock pushbutton input (close circuit to unlock) | 1 | 1 | 0 | 0 | 0x02 | 3 | Function Options for Input Terminal SW2 | Range: 0 ~ 3. Default: 3. Value = 0: The input is disabled. Value = 1: Normally Closed Door sensor. Value = 2: Normally Open Door sensor. Value = 3: External unlock pushbutton input (close circuit to unlock) | 1 | 1 | 0 | 0 | 0x03 | 4 | Battery Low setting | Reporting the battery low warning message when battery level reaches this value in percentage. Range: 10 ~ 50 (10% to 50%). Default: 10% | 1 | 1 | 0 | 0 | 0x0A | 5 | Battery Scheduled Report Interval | The battery level scheduled report interval time is based on every 30 minutes per kick. The value N related to the time in minutes is N x 30 minutes. Range: 0~120. Default: 12 (12x30 =360 minutes). Value = 0: Disable Battery level scheduled report. | 1 | 1 | 0 | 0 | 0x0C | 6 | The 12V DC Power Output Options | This parameter is used to enable/disable the 12V CD power output at the power output terminal. Range: 0~1. Default: 0. Value = 0: The power output is disabled; Value = 1: The power output is enabled. | 1 | 1 | 0 | 0 | 0x00 |
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | Page 8.
Ness Z-Wave DLC is a SmartStart enabled device allowing it to be added into a Z-Wave network by scanning its Z-Wave QR Code with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. *Requires a SmartStart compatible controller and app. Ness Z-Wave DLC must be within network range. | 1 | Classic Inclusion | To add the device into the Z-Wave™ network:
1) Power on device and ensure it has been factory defaulted.
2) Set the primary controller into inclusion mode.
3) Click the Action Button once the device enters the inclusion mode and the Red LED starts fast flashing.
Note: Inclusion mode can be cancelled by clicking the Action Button once again before the device starts the learning process (controller has not yet started inclusion mode), the device exits the learning mode and Red LED stops fast flash.
4) The inclusion is processing.
5) If your Z-Wave controller supports S2 Access encryption and DSK, enter the first 5 digits of the DSK located at bottom of the QR image.
6) If the inclusion is successful, the Red LED stops fast flashing and the Green LED turns on for 2 seconds. | 2 | Classic Exclusion | You may need to refer to your Z-Wave™ gateway’s instructions for removing devices.
Exclusion
To remove the device from the Z-Wave network:
1) The device is powered
2) Set the primary controller into exclusion mode.
3) Click the Action Button once the device enters the inclusion mode and the Red LED starts fast flashing. Click the Action Button once again before the device starts the learning process (controller has not yet started inclusion mode), the device exits the learning mode and Red LED stops fast flash.
4) If the exclusion is successful, the Red LED stops flashing and the Green LED turns on for 1 second. | 4 | Wake-Up Procedure | Not required. The product is always awake. | 5 | Factory Reset Procedure | To Factory Default Ness Z-Wave DLC
Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Reset the device to factory Default:
1) The device is powered
2) Press and hold the action button down for 20 seconds. When the action button has been held for greater than 3 seconds, the Red LED starts fast flash, and the Fast flash will stop after 20 seconds. Once the action button is released, the Green LED will turn on for 1 second indicating that the device has been reset.
3) Release the action button while the Red LED is fast flashing (before 20 seconds), the device reset will be cancelled, and the Red LED will stop fast flash. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Access Control | Door state: Window/door is open | Access Control | Door state: Window/door is closed |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Is Flirs | Yes |
|---|
Supports SmartStart | Yes |
|---|