Product Recognition | |
|---|
Certification Number | ZC14-26090638 |
|---|
Name | Novon Dimmer Plug |
|---|
Short Description | Use the 800LR smart dimmer in smart lighting applications for smooth lighting control and reliable wireless communication. |
|---|
Description | Use the 800LR smart dimmer in smart lighting applications for smooth lighting control and reliable wireless communication.
Support Z-Wave LongRang |
|---|
Brand | NOVON |
|---|
Brand Owner | NOVON |
|---|
Identifier | NVN-210 |
|---|
Product Line | Light Switches |
|---|
OEM Version | HW: 01 FW: 01.00 |
|---|
Hardware Platform | EFR32ZG23A |
|---|
Z-Wave Version | 7.24.1 |
|---|
Library Type | END_NODE_ENHANCED_232 |
|---|
Device Type | Multilevel Switch DT |
|---|
Role Type | ROLE_TYPE_END_NODE_ALWAYS_ON |
|---|
Manufacturer ID | 0x046D |
|---|
Product Type ID | 0x27D8 |
|---|
Product ID | 0x1A30 |
|---|
User Icon | 0x0600 |
|---|
Installer Icon | 0x0600 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz, US_LR: 912.00MHz, 920.00MHz |
|---|
Categories | Dimming Lighting Devices |
|---|
Countries / Regions | Canada, Mexico, United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_SWITCH_MULTILEVEL_V4 | Multilevel Switch V4 | 0x26 | 4 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 |
|
|---|
S2 Classes | S2_AUTHENTICATED, S2_UNAUTHENTICATED |
|---|
Documents | Category | File |
|---|
Manual_English | |
|
|---|
Features | Feature | Values |
|---|
Color | | Electric Load Type | Value |
|---|
Incandescent | Dimmable LED |
| Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
| Neutral Wire Required | | Switch Load Capacity Watts | | Z-Wave Scene Type | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
1 | 5 | 0 | Lifeline | 0x0001 | 2 | 5 | 0 | Single Press button | 0x2001 |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
|---|
3 | LED light mode | Set the LED Light Mode. | 1 | 1 | 0 | 0 | 0x01 | 31 | Maximum Brightness Threshold | Maximum Brightness Threshold. | 1 | 1 | 0 | 0 | 0x63 | 41 | LED brightness | Set the LED brightness. | 1 | 1 | 0 | 0 | 0x00 | 84 | Reset Factory Default | Reset Switch to Factory Defaults. | 1 | 1 | 0 | 0 | 0x00 |
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | The QR code are stocked to the side of the case, DSK is included in the QR code.
The DSK code can be found on the DSK label which is attached on the packaging box. | 1 | Classic Inclusion | * The device support two methods of inclusion, When using a Z-Wave Plus® certified controller choose Network Wide Inclusion or SmartStart.
* TAP the button once times to ADD/INCLUDE the device.
* Network Wide Inclusion To A Z-Wave® Network
* TAP the button once times to REMOVE/EXCLUDE the device
* Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
* When prompted by your primary controller, click the Z-Wave button one times . . | 2 | Classic Exclusion | * The device support two methods of inclusion, When using a Z-Wave Plus® certified controller choose Network Wide Inclusion or SmartStart.
* TAP the button once times to ADD/INCLUDE the device.
* Network Wide Inclusion To A Z-Wave® Network
* TAP the button once times to REMOVE/EXCLUDE the device
* Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
* When prompted by your primary controller, click the Z-Wave button one times . . | 5 | Factory Reset Procedure | Factory Reset: Remove the switch from power. Press and hold the manual button, plug the switch in and continue holding the manual button for 3 seconds.
Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable. |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Supports SmartStart | Yes |
|---|