Product Recognition | |
|---|
Certification Number | ZC10-18086204 |
|---|
Name | Open/Close Sensor |
|---|
Short Description | The Open/Close Sensor is a product for IoT with magnetic sensors and with functions of Z-Wave communication. It can collect sensing data that door open/close by using a magnet. And it sends the data to the gateway. |
|---|
Long Description | The Open/Close Sensor is a product for IoT with magnetic sensors and with functions of Z-Wave communication. It can collect sensing data that door open/close by using a magnet. And it sends the data to the gateway.
The Open/Close Sensor has the following general features:
- Z-Wave communication
- Sensing with
Open/Close sensor (detecting the opening and shutting of the door by using a magnet),
Tamper switch. |
|---|
Brand | Sharp Corporation |
|---|
Product Identifier | DN3G6JA082 |
|---|
OEM Version | HW: 255 FW: 0.84 |
|---|
Hardware Platform | SD3502 |
|---|
Z-Wave Version | 6.71.03 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x010B |
|---|
Product Type ID | 0x4761 |
|---|
Product ID | 0x0082 |
|---|
User Icon | 0x0C06 |
|---|
Installer Icon | 0x0C06 |
|---|
Frequency Plans | JP: 922.50MHz, 923.90MHz, 926.30MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | Japan |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC | Manufacturer Specific | 0x72 | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Quantity | | Battery Type | | Supported Notification Types | Value |
|---|
Access Control | Home Security |
| Sensors | Value |
|---|
Open/Closed (Binary) |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 5 | 0 | Z-Wave Plus Lifeline |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
2 | Enable switch | Enable switch of "Alarm Notification" report | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 0 | Open/Close OFF | 1 | 1 | Open/Close ON |
|
|
|---|
Texts | ID | Description | Value |
|---|
5 | Factory Reset | Press the button over 10 seconds and release.
Please use this procedure only when the network primary controller like the gateway is missing or otherwise inoperable. | 4 | Device Wake-Up | Press the button one push and release.
“Wakeup Notification“ will be sent. | 2 | Exclusion | -Remove (exclusion)
Set the controller to the status for “Remove”.
Press the button over 3 seconds and release.
LED blinks when “Remove” is completed. | 1 | Inclusion | -Add (Inclusion)
Insert a CR123A, and LED blinks.
Set the controller to the status for “Add”.
Press the button over 3 seconds and release.
About “Add” is completed, LED turns off.
(If security include, LED turns off will soon after “Preparing inclusion” process.)
Note) After inclusion completed, this sensor keep waking about 40 seconds, for interview process.
During this time, button operation is disabled. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Access Control | (Refer to parameters): State idle | Home Security | (Refer to parameters): State idle |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
General purpose |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|