Product Recognition | |
---|
Certification Number | ZC10-17065655 |
---|
Name | Open Sensor |
---|
Short Description | Window & door open sensor |
---|
Long Description | Detecting the status of Door or Windows equipped with Z-Wave Open Sensor and notifying the status to a customer via smart phone application. |
---|
Brand | LG Uplus |
---|
Product Identifier | OSLI-01 |
---|
OEM Version | HW: 1 FW: 39.26 |
---|
Hardware Platform | SD3502 |
---|
Z-Wave Version | 6.61.00 |
---|
Library Type | SLAVE_ENHANCED_232 |
---|
Device Type | Notification Sensor |
---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
---|
Manufacturer ID | 0x0273 |
---|
Product Type ID | 0x0003 |
---|
Product ID | 0x0001 |
---|
User Icon | 0x0C06 |
---|
Installer Icon | 0x0C06 |
---|
Frequency Plans | KR: 920.90MHz, 921.70MHz, 923.10MHz |
---|
Categories | Sensors |
---|
Countries / Regions | Republic of Korea |
---|
Supported Command Classes | Identifier | Name | Key | Version |
---|
COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_NOTIFICATION_V3 | Notification V3 | 0x71 | 3 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | Firmware Update Meta-Data V2 | 0x7A | 2 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
---|
Documents | |
---|
Features | Feature | Values |
---|
Sensors | Value |
---|
Open/Closed (Binary) |
| Supported Notification Types | |
|
---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
---|
1 | 1 | 0 | Z-Wave Plus Lifeline |
|
---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
---|
1 | Battery report Period | Wake Up period x Configuration value = Battery report Period | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 255 | Default 24 (0x18), 0x01~0xFF in 15 minute increments |
|
|
---|
Texts | ID | Description | Value |
---|
4 | Device Wake-Up | 1. Device sends Wake up Notification by every 15 minutes.
2. Devices also sends Wake up Notification when inclusion/exclusion button is shortly pressed regardless of 15minutes interval. | 6 | Additional Special Features | Firmware auto update via over the air | 1 | Inclusion | 1. Press & hold inclusion/Exclusion button during 5 seconds when Open Sensor is exclusion status.
2. Press for 5 seconds, LED is turn on.
3. Open sensor will try inclusion for 30 seconds when button is released. | 5 | Factory Reset | 1. Press & hold inclusion/Exclusion button during 10 seconds.
2. LED will blink while holding the button.
3. Factory reset will be done in 10 seconds after releasing button and blink 5 times with 100ms interval.
※ Please use factory reset only when the network primary controller is missing or otherwise inoperable. | 2 | Exclusion | 1. Receiver will stay exclusion waiting mode.
2. Press & hold inclusion/Exclusion button during 5 seconds when Open Sensor is exclusion status.
3. Press for 5 seconds, LED is turn on.
4. Open sensor will try exclusion when button is released.
5. If exclusion is successful, LED will blink 3 times with 250ms interval. |
|
---|
Supported Notification Types | Notification Type | Event / State |
---|
Home Security | (Refer to parameters): State idle |
|
---|
Supported Multilevel Sensors | Multilevel Sensor Type |
---|
0x02 |
|
---|
Supports NWI | Yes |
---|
Supports Explorer Frames | Yes |
---|