Product Recognition | |
|---|
Certification Number | ZC10-17065639 |
|---|
Name | Open Sensor |
|---|
Short Description | Detecting the Door/Window status(open/close) in real time and anywhere. |
|---|
Long Description | Remote Access via smart phone APP
Detecting the status of Door/Windows equipped with Z-WAVE Open Sensor and notifying the status to a customer.
Checking the battery usage and reporting the low battery alarm. |
|---|
Brand | LG U+ |
|---|
Product Identifier | OSR-01 |
|---|
OEM Version | HW: 1 FW: 39.20 |
|---|
Hardware Platform | ZM5101 |
|---|
Z-Wave Version | 6.61.00 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x022c |
|---|
Product Type ID | 0x0003 |
|---|
Product ID | 0x0001 |
|---|
User Icon | 0x0C06 |
|---|
Installer Icon | 0x0C06 |
|---|
Frequency Plans | KR: 920.90MHz, 921.70MHz, 923.10MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | Republic of Korea |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_NOTIFICATION_V3 | Notification V3 | 0x71 | 3 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | Firmware Update Meta-Data V2 | 0x7A | 2 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Neutral Wire Required | | Firmware Updatable | Value |
|---|
Updatable by Professional/Technician |
| Sensors | Value |
|---|
Open/Closed (Binary) |
| Outdoor Use | | Battery Type | | Color | | Battery Quantity | | Supported Notification Types | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 5 | 0 | Z-Wave Plus Lifeline |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
1 | Battery Period | Battery Report Period Value. The battery report period is in 15 minute increments. For example, the default value of 24 * 15 minutes = 360 minutes or 6 hours. | 0 | 1 | 0 | 0 | 24 | From | To | Description |
|---|
1 | 255 | Default 24 (0x18), 0x01~0xFF in 15 minute increments |
|
|
|---|
Texts | ID | Description | Value |
|---|
4 | Device Wake-Up | a. Device sends Wake up Notification by every 15 minutes.
b. Devices also sends Wake up Notification when inclusion/exclusion
button is shortly pressed regardless of 15minutes interval. | 1 | Inclusion | a. Press & hold Inclusion/Exclusion button for 5 seconds when Open
Sensor is exclusion status.
b. LED of Open sensor will be on 5 seconds later.
c. Open sensor will try Inclusion for 30sec when button is released.
d. LED will blink 3 times if Inclusion is successful. | 2 | Exclusion | a. Receiver will stay exclusion waiting mode.
b. Press & hold Inclusion/Exclusion button for 5 seconds when Open
Sensor is Inclusion status.
c. LED of Open sensor will be on 5 seconds later.
d. Open sensor will try Exclusion when button is released.
e. LED will blink 3 times if Exclusion is successful. | 5 | Factory Reset | a. Press & hold Inclusion/Exclusion button for 10sec.
b. LED will blink while holding the button.
c. Factory reset will be done in 5sec after releasing button and LED will
blink 5 times.
Please use this procedure only when the network primary controller is missing or otherwise inoperable. | 6 | Additional Special Features | a. Firmware auto upgrade via OTA. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Access Control | (Refer to parameters): State idle |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
General purpose |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|