| 2 | Temperature Adjustment | Temperature correction. The given value changes the displayed temperature by 0.1K | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 127 | 0.1K | | -1 | -127 | - 0.1K | | 0 | 0 | Disabled |
|
| 1 | Siren Tamper Mode | Sets the tamper triggering mode when removed from the holder | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | Triggers automatically when it is removed from the holder. Must be turned off, using the button or from the controller | | 2 | 2 | Does not trigger at all, when removed from the holder. Service Mode | | 1 | 1 | Triggers automatically when it is removed from the holder and turns off, when placed back on the holder |
|
| 5 | Siren Mode | Determines how the Siren shall react on alarm | 0 | 1 | 0 | 0 | 2 | | From | To | Description |
|---|
| 0 | 0 | Siren Only | | 1 | 1 | Flash Only | | 2 | 2 | Flash plus Siren |
|
| 6 | Auto Off | If the value is set, the siren will be switched off automatically after a defined alarm time in Minutes. | 0 | 1 | 0 | 0 | 5 | | From | To | Description |
|---|
| 0 | 0 | No Auto Off | | 1 | 127 | after X Minutes |
|
| 3 | Send unsolicited Temperature Report | Temperature Threshold to send unsolicited Temperature Update | 0 | 1 | 0 | 0 | 10 | | From | To | Description |
|---|
| 0 | 127 | 0.1 K | | -1 | -127 | * 0.2 K |
|